NAME :- OM PRAKASH DUBEY
Father Name :- SHRI DIWAKER DUBEY
DATE O/B:- 23- SEP-1975
Phone No.:- 758**-*****
Mobile No.:- 932**-*****
E-mail add :- ****************@*****.***
Address :- Bancchor estate phase-2 Satyam Vihar Colony near
Shivam school Raipura, Raipur (C.G.) Pin.-492010
QUALIFICATION
DIPLOMA IN ELECTRICAL ENGINEERING FROM GOVT. POLYTECNIC JABALPUR (M.P.)
OTHER QUALIFICATION
(1) M.A. (poly.) R.D.V.V. JABALPUR (M.P.)
(2) B.COM.(management.) R.D.V.V. JABALPUR (M.P.)
(3) Post Graduate Dip. In Management from IGNOU
(4) MBA in Operation management from IGNOU
IT EXPOSURE
MS-OFFICE & C++.
COMUNICATION SKILL
HINDI AND ENGLISH.
EXPERIENCE
Having 17 to 18 years;
WORKING AT PRESENT
M/S JAYSAWAL NECO INDUSTRIES LTD (SPD) RAIPUR
65MW(2*4MW, 1*7.5MW, 1*7.5MW, 2*15MW & 2*6 mw)
COAL AND BLAST FURNACE GAS BASED CAPTIV POWER PLANT.
DESI. :- Manager Electrical (P/P) ( FROM MAY-2007
MY JOB RESPONSIBILITY COVERS THE FOLLOWING PROFILE:-
Maintenance of MCC, LCSS and PDB in L.T. section and maintenance of H.T. Switch Gear (VCB) in H.T. Section. Operation & Maintenance of L.T. & H.T. motors (up to 270 kw) with there starter. Operation & Maintenance of Power Transformer 1*16 Mva,132/6.6kv and. Operation & Maintenance of 3*1.6 Mva X-mar for p/p auxiliary.
O & M of Generator 7.5&15mw/11kv, 7.5& 4mw6.6kv with there exciter. & its relay panel. Maintenance of LAPT & SPC, during break down and shut down time. ESP Operation & Maintenance (make Thermax). Operation & Maintenance of VVVF Drives and fault finding.
CAREER HISTORY
(1). M/S JAYSAWAL NECO INDUSTRIES LTD (SPD) RAIPUR
65MW (An ISO 9001 Certified Company)
COAL AND BLAST FURNACE GAS BASED CAPTIV POWER PLANT.
DESI. :- MANAGER Electrical (P/P) ( FROM MAY-2007
(2). M/S JAGDAMBA POWER & ALLOYS LTD RAIPUR (C.G.)
(A 25 MW COAL BASED CAPTIV POWER PLANT)
Engineer (E) (from sep.-2005 to may.-2007)
Scope of work:- Maintenance of MCC, LCSS and PDB in L.T. section and maintenance of H.T. Switch Gear (VCB) in H.T. Section. Operation & Maintenance of A.C. motors (up to 570 kw) with there starter. Operation & Maintenance of Power Transformer 1*25 Mva,132/11kv and & its Relay panel. Operation & Maintenance of 2*2.8Mva X-mer for p/p auxiliary's. O & M of Generator 25mw/11kv, with there exciter. & its relay panel. Maintenance of LAPT & SPC, during break down and shut down time. ESP Operation & Maintenance (make Thermax). O&M of DC motor of 455kw and DC-Drive (ABB) DCS-501 for given DC motor. O&M of AC DRIVE- ACS-550 & ACS-800 (ABB). O&M of 33kv/415v sub-station with 550kva Transformer.
(3). M/S HIRA STEELS LTD RAIPUR (C.G.)
(An Automatic 350MT ROOL MILL)
Assi. Engineer (E) (from jan.-2001 to sep.-2005) S/I from Apri-2002.
Scope of work:- O&M of Thyristor control DC Drive ADD-32 (NELCO) and DC
motor up to 300kw.O&M of AC Drive ACS-550 & ACS-400 (ABB).
O&M of AC Motors up to 150kw and 1500HP motor with there starter including LRCS. Maintenance of motor & starter of EOT crane 5 to 25 ton.
Operation & Maintenance of 33kv/415v sub-station with there 4-Mva X-mer.
(4). M/S VEE KAY ELECTRICAL LTD JABALPUR (M.P.)
(Manufacturing unit of conductor ACSR, RABIT etc & Telecom cable.)
Sub-Engineer (E&T) (from jan.-2000 to nov-2000)
CAREER OBJECTIVE
To strive for excellence in Technical field through a continuous Process of learning and Enhancement of knowledge and skills .
PROJECT EXPIRIENS
(1) JAGDAMBA POWER AND ALLOYS LTD SILTARA RAIPUR (C.G.)
1x25MW/11KV CHINA make Turbine and VA-TECH HYDRO make Generator erection and commissioning with the TG MCC erection and commissioning. Erection and commissioning of boiler MCC, DM-PLANT MCC, coal handling & ESP MCC. Erection and commissioning all AC and DC motor of Boiler, TG, CHP, A.C.S.C. and ESP. Erection and commissioning of 33/.40-kv sub-station with 550kva X-mer. Erection and commissioning of 132kv switch yard with 20/25 Mva X-mer & its Relay and control panel.
(2) JAYASWAL NECO IND LTD SILTARA RAIPUR (C.G.)
2x06 MW/6.6KV CHINA made Turbine and SANDONG JINON make Generators erection and commissioning with the TG MCC erection and commissioning. Erection and Commissioning of boiler MCC, DM-PLANT MCC, Erection and Commissioning all AC and DC motor of Boiler, TG, cooling tower etc. Erection and Commissioning of 33/.40-kv sub-station with 2*(7.5) Mva X-mer. 2*1.6 Mva X-mar for the auxiliary of both unit and pcc too.
(3) JAYASWAL NECO IND LTD SILTARA RAIPUR (C.G
Involved in 132kv/33kv sub station Erection and Commissioning with 1*25 Mva x-mer.
and its Relay and control panel and proper interlocking arrangement with other generation
unit.
(4) JAYASWAL NECO IND LTD SILTARA RAIPUR (C.G
finished 18 ton fire tube boiler Erection, Commissioning and testing.
In one month with three nos. ABB 850 drive commissioning, testing and running.
THANKING YOU
Place:- OM PRAKASH DUBEY
DATE:-