Post Job Free

Resume

Sign in

Plant Technician

Location:
Kuwait
Salary:
600
Posted:
July 21, 2018

Contact this candidate

Resume:

CURRICULUM VITAE

ANOOP V.P

Mangaf

Al Ahmadi,

Kuwait.

Mob: +965-******** Email: ac6ctn@r.postjobfree.com

OBJECTIVE:

Seeking a position as an INSTRUMENT FORMAN/ SUPERVISOR where my experience, training and good work habits will be asset to your company.

SUMMARY OF EXPERIENCE:

Over 12 Years’ Experience in instrumentation in maintenance, commissioning & construction in various industries such as oil & gas petrochemical and cement Industries in India & Gulf countries.

SUMMARY OF EDUCATION:-

3 Year Diploma in Electronics & Telecommunication

2 Year Certified Diploma In Process Control Instrumentation

Pre Degree from M G University Kerala

Software Engineering

EMPLOYMENT HISTORY:

At present working as an Instrument Technician in EQUATE Petro Chemical Company in Kuwait for Maintenance Division from 13th Aug. 2009 till date.

Worked as an Instrument Technician in KNPC (LNG) GASPORT Project Commissioning From 1st April 2009 to 12th Aug. 2009.

Worked as an Instrument Technician in Hyundai Heavy Industries Ltd

E&I Team on Oil & Gas project of KOC (Kuwait Oil Company) sites- NTF, STF, NPP & KNPC – Crude oil Export Facilities. From 7th Feb 2008 to 14th Mar 2009.

Worked as an Instrument Technician in Travancore Cements Kerala, Kottayam for the cement plant maintenance division.in 2007

Worked as an Instrument Technician in Hi-Tech engineering company in Kerala, for their work shop division.in 02/08/2004 to 31/05/2007

TECHNICAL SKILLS:

Report to Instrument Engineer, Responsible to carry out the following activities,

Reviewing of instrumentation drawings such as instrumentation location and cable tray layout, installation hook ups, junction boxes, loop schemes & cable schedules.

Experience in preparation/ review of all types of field instruments, material requisitions, cable schedule, instrument data sheets, Hook up diagrams, loop diagrams, P & ID’s, & As built drawings for instruments.

Perform troubleshooting, repair and maintenance including preventive, predictive and corrective maintenance for a variety of Instrument Equipment’s.

Having good knowledge of FIELDBUS & HART Foundation.

DCS system HONEYWELL TDC 3000 and PKS (Process Knowledge System)

Having good knowledge of ESD TRICONEX (TMR-Triple Modular Redundant) system with two out of three tripping system.

Experienced in the Honeywell Burner Management Systems (BMS).

Having good knowledge of gas compressors and chilling compressors (MRU system)

Level measurement- Magnatrol 705seires magnetic type level measurement, K-Tek AT-100 magnetic level measurement, Rosemount 3051 capillary type level measurement, ENRAF, VEGA PLUS & E + H (Endress + Hauser ) Level transmitters for tank gauging level with Ultrasonic level measurement, Guided wave Radar type liquid & solid level measurement system.

Temperature measurement- ABB, Rosemount 3144P, PT-100 2 wire, 3wire & 4 wire and thermocouples ( winding,bearing,gear temp & lube oil temperature measurement)

Pressure measurement – Rosemount 3051series (PT & PDT ) smart transmitters, pressure switches

Flow measurement- Rosemount vortex flow transmitters,Endress Hauser mass flow meter Rosemount 3051 smart transmitters, digital flow XMT868 i Panametrics ultrasonic liquid flow transmitters, 3095 multi variable mass flow transmitters, flow indicators

Having god knowledge of Transmitters: ROSEMOUNT, ENDRESS HAUSER, ABB, MICROMOTION, VEGA, MAGNATROLL etc.

VALVES: MASONEILAN, FISHER, VALTEK, FLOWSERVE,BETTIS,AIR TORQUE,METSO valves

Positioners: Masoneilan SVI 1 and SVI 2, FISHER DVC 6000 and 6200 digital smart positioners with HART and FIELDBUS application.

I/p convertors: Flowserve, Foxboro, fisher & bells

Well-known with the Plant Running, Predictive, Preventive, Breakdown and Corrective Maintenance.

Specialist in Installation & Calibration of different types of the Modern Smart Electronics & Pneumatic instrument.

Skilled in PLC, DCS, ESD Plant Automation Control System.

Effective knowledge of the Lock out Tag out Processes.

Able to do a job independently.

Responsibilities involve installation, calibration, and loop checking and commissioning and trouble shooting of Instruments.

Alarm and trip checks, calibration of instruments like transmitters, level trolls, switches, stroke checking of control valves, I/P Converters, and field calibrating them if required.

Attend daily jobs allotted by the Shutdown Supervisor, procuring the work permit and coordinate with the area operators and control room operators for attending the jobs.

Installing electronic transmitters in the place of pneumatic transmitters and commissioning them as per the procedures lay down.

Attended Safety training conducted at the plant site and listened to fire & Safety instructions and brought them in practice.

Having good knowledge of plant safety rules & regulations.

Good knowledge about Work Permit System and several kinds of permits like Cold work permit, hot work permit, Confined space entry permits.

Ability to read Engineering Drawings, Loop diagrams, P&ID Drawings Logic Diagrams, Installation Details & Hook up Drawings.

Need to co-ordinate with QC (Quality Control) department for the KOC site inspection, punch list clearance etc. Also, responsible for making the inspection and Test records.

Ability to do the job independently.

To Calibrate, Test, Operate, and Repair the Instruments based upon several parameters

Routine check of different type of gauges and transmitters

Having good knowledge about Bentley Nevada Vibration proximitor system

Doing Plant Start-up & Shut down Activities. During yearly shutdowns.

Training Programs history:-

Safe work permitting & Procedures.

Confined space entry

Elevated work

Incident investigation and Reporting

PPE (Respiratory and Non-respiratory)

Handling hand and power tools

Fire, class of fire & fire prevention

Electrical safety and precautions.

Basic First aid system

Working at heights, scaffolding and ladder safety

Compressed gas cylinders

Hazards and Identification of hazards

Environment & Health awareness pollution

Chemical handling and hazards

Vehicle and Equipment safety

House Keeping

Emergency and evacuation procedures

Personal Details & Passport Details:-

Nationality : Indian.

Date of Birth : 27 mar 1982

Languages Known : English, Hindi, Malayalam & Tamil.

Marital status : Married.

Passport No. : J4748111

Place of Issue : Cochin, India.

Date of expiry : 30 may 2021

Declaration

I hereby declare that the entire details furnished above are true and valid to the best of my knowledge and belief.

PLACE : KUWAIT

Regards,

Anoop V Ponnappan



Contact this candidate