To,
Dear Sir,
Presently I am Working with Lanco Anpara power Limited (An unit of LANCO Groups) at Anpara, Sonebhadra, Uttar Pradesh as AGM-Electrical in 2*600 MW thermal based Power Plant.
I have 21 years of experience in various fields in thermal power plant like Project, Erection, commissioning, maintenance (O&M), and trouble shooting of all electrical equipments and various jobs for Unit stabilization as well as reliability improvement.
I have also handled various other activities in thermal power plants during project stage like coordinating with various vendors/ EPC group for project schedule monitoring, day to day progress report, study and finalization of electrical drawings/schemes, protocols during initial/commissioning stage of power plants.
I am confident that I can perform the assigned job effectively and I am excited about the idea of working for a dynamic and healthy environment.
Given the opportunity, I would be pleased to meet with you and discuss how I might be able to promote the growth of your company. If you would like to schedule an interview or otherwise discuss my interest in the position, Please call me at +91-967*******.
I am looking forward to meeting with you.
Sincerely,
Date:-17/09/2018
Binod Kumar Panda Place:-Anpara.
Professional Synopsis:
At present i am looking after maintenance (O&M), trouble shooting, initiating & implementation of various modifications in electrical equipments for stabilization of unit/equipments as well as reliability improvement in BTG, BOP and switch yard.
I have also handled various other activities in thermal power plants during project stage like coordinating with various vendors/ EPC group for project schedule monitoring, day to day progress report, study and finalization of electrical drawings/schemes, protocols during initial/commissioning stage of power plants.
Job Objective:
Seeking managerial assignments in Project management, Operation and Maintenance (O&M), Plant stabilization and various modifications to enhance the equipment availability/efficiency with a high growth oriented organization.
Personal Profile:
Name
Binod Kumar Panda
Date of Birth
07.06.1972
Permanent and
Mailing Address
C/O: Nrusingha Ch. Panda.
At : Bodakshasan, P.O: Bodak.
Dist : Bhadrak, (Odisha) 756163.
Contact Phone No: +91-967*******/993-***-****
E-mail ID
**********@*****.**.**
****************@*****.***
Educational Qualification
BE in Electrical Engg., First Class (72.82%)GPA-7.33 & CGPA-7.47 (from Institution of Engineers, Kolkata ) After Diploma in Electrical Engg., First Class (65%), Passed out-1996 (From IEM Jeypore, Odisha)
Additional Qualification
Master of Business Administration (MBA) in Project Management, Grade-A from SMU, Passed out- 2017
Professional License
SCC License holder from Govt. of Orissa.
License No:- 6001/ 23, Date of issue 18/05/2002.
International Passport No.
G5098041
Computer working station
Auto Cad 2004,2006,Windos9x,2000,XP.
Major Achievements:
I have initiated for various modifications and implemented after approval by corporate engineering/ modification committee to enhance maximum availability of equipments and plant reliability.
I have very good experience in maintenance of various electrical equipments as well as preparation of their SOP considering the best maintenance procedure
I have introduced various systems in Lanco Anpara Power limited during project stage related to erection and commissioning of electrical equipments such as pre-commissioning, commissioning check sheet, Protocol system etc.
Managerial Experience:
Identifying and implementation of various improvement plans/ projects for enhancement of system/ plant reliability.
Planning and implementation of all jobs for unit AOH/COH.
Knowledge of preventive, breakdown and planned maintenance.
Strategic development of system performance by preparation and review the standard operating procedures (SOP).
Effective maintenance planning for better utilization of equipments & resources
Spare management for plant running and AOH/COH.
Study and monitoring of the equipment healthiness/performance.
Better co-ordination in-between inter department.
Root Cause Analysis (RCA) and improvement in the system for zero breakdown.
Ensure safe working conditions for equipment and people.
Ability to motivate others to meet various departmental objectives.
Technical Experience:
Knowledge in generator protection system, and its maintenance.
Experience in maintenance of generator excitation system, generator, and generator synchronization system.
Experience in operation maintenance of various electrical equipments such as Generator transformers, Unit transformers, Excitation transformers etc.
Various activities during thermal power plant projects.
Commissioning and maintenance of Analog type DC Motors and its starters.
Maintenance and trouble shooting of variable frequency drives ( VFD).
Maintenance of Diesel generators, alternators and their power/control panels.
Commissioning and maintenance of Analog type DC Motors and its starters
Commissioning and maintenance LT & HT Feeders and HT/LT motors.
Commissioning and maintenance of plant DC systems & battery Chargers
Maintenance of Diesel generator and their changeover systems and handling of emergency DC drives & DC systems.
Effective job planning and handling the various activities during short shutdown/ AOH/COH.
Handling of Turbine generator (TG) overhauling through external vendors.
Employment history and Job Responsibility:
1-Present Position: AGM-Electrical From: 8th Sept. 2009 to till date.
M/S Lanco Anpara Power limited (An unit of LANCO groups) at Anpara, Sonebhadra, Uttar Pradesh having 2* 600 MW Thermal Power plant. Both units are under running stage since 2012.
Lanco Infratech has subsidiaries and divisions across a synergistic span of verticals. These include Construction, Power, EPC, Infrastructure, Property Development, and Renewable energy.
Responsibility: I am looking after maintenance (O&M), trouble shooting, initiating & implementation of various modifications in electrical equipments for stabilization of unit/equipments as well as reliability improvement in entire area.
I have also handled various other activities in thermal power plants during project stage like coordinating with various vendors/ EPC group for project schedule monitoring, day to day progress report, study and finalization of electrical drawings/schemes, protocols during initial/commissioning stage of power plants.
2-Post held : Manager ( E&I) CPP: From: 5th October 2007 to 7th Sept. 2009. M/S Maithan Ispat Limited (An Integrated Steel Plant) at Kalinga Nagar, Jajpur, Odisha.
Responsibility: I was joined as HOD-Electrical and looked after erection Testing & commissioning of all electrical equipments in power plant and its auxiliaries and also looked after O&M after plant commissioning. The plant was successfully commissioned in May-2008.
3-Post held : Asst. Manager ( Electrical) From: April-1997 to October-2007
Emami Paper Mills Ltd., Unit: Balasore a paper Division (An ISO-9000 Company) of Emami Group of Companies having capacity 450 Tonns/ day and an annual turnover of 600 Crores.
Worked as HOD-electrical for completion of power plant Project, erection, commissioning & Maintenance of the Electrical Equipments in captive power plants and its auxiliaries. After completion I was also looked after O&M of both units.
Professional Training:
“Generator & generator Protection” Training from Power system Training Center (A Power linker Group) in Mumbai. During the year of 2006.
“Training ON Power Plant Engineering”( Includes Generator Protections, Excitation Systems, Boiler Engineering, Thermal Engineering,Control & Instrumentation and other details for a Power Plant.) at Chongqing University China. From 21 June 2010 to 20th September 2010
Training On “ Protection of Large Generator through Siemens Protection Relay” at Siemens Training center, Mumbai in 2011.
Present Salary : Rs 21 lakhs + Accommodation and other parks.
Expected Salary : Negotiable
Thanking you
yours faithfully
Date : 17/09/2018
Place : Anpara
Binod Kumar Panda