DEEPAK KUMAR ROUT
At- Danarkul, Bari, Jajpur
Odisha-755017
07.06.2018
Dear Madam,
With great willingness, I am applying for the position of engineer at your company. I finally believe that my education, skill set, intensive training and extensive experience make me a suitable candidate for your Organization.
I am certified in electrical installation and hold a degree in electrical engineering from B.P.U.T, Rourkela, Odisha .As an individual who is interested in continuous professional development, I have dedicated more than 5 years of experiences to working with in the electrical Industries. This has resulted in professional competency in all operational and technical aspects of systems implementation.
Employed with SIEMENS IPM DIVISION as an Engineer, I have demonstrated strong problem solving skills and the ability to work in high pressure and challenging working environments. My responsibilities varied through commissioning, Maintenance, Installation and testing of electrical systems. In addition I was also rolled upon to manage Vendors and Execute Projects and Maintenance Strategies.
I would welcome the opportunity to meet you and I am sure after appraisal of my resume, you will see I am an individual with excellent potential in an organization.
I look forward to hearing from you in due course.
Sincerely,
Deepak Kumar Rout
*****-****.**************@*****.***
Mob- 740-***-****, 732-***-****
Deepak Kumar Rout
Licence No-10120 (MV)
Contact: +91-740*******, 732-***-****
E-Mail: ****.**************@*****.***
CAREER CONSPECTUS
5.5 years of cross-cultural experience in the areas of following electrical areas.
- Strategic Planning - Site / Construction Management - Testing - Design Reviews - Liaison Work - Resource Management - General Administration
A Site Engineer adopt in handling multi-discipline contracts involving Operation, Maintenance & Testing of Electrical and Commissioning Jobs.
Deft in overseeing project activities from conceptualization to execution including technical specifications, stage inspections, progress monitoring, site management and manpower planning.
Excellent relationship management, analytical and negotiation skills with deftness in swiftly ramping up projects in coordination with clients, contractors, vendors and consultants.
CAREER CONTOUR
Currently Working as Site Engineer at Siemens Limited in IPM RC-IN DF CS Division, Kalwa, Mumbai since 05.06.2017 at following sites.
FIAT India Automobile Limited, Ranjangaon, Pune.
TATA Motor,Dharwad,Karnataka
Worked as Electrical Engineer at Techsupport, Bhubaneswar from 23.04.2016 to 05.06.2017 at following Sites.
Southco Energy Utilities,Govt of Odisha
Utkal Aluminium International Limited, Rayagada, Odisha.
Worked as Site Engineer at JBS Enterprises Pvt Ltd, Thane from 18.06.2014 to 11.04.2016 at following sites.
GMR Energy Limited,Alwar,Rajasthan
LAVASA Corporation Limited, Lavasa, Pune.
BE Electrical, Sitamau, MP.
Worked as Site Engineer at S.B. Electricals & Contractor, Dharwad from 03.12.2012 to 10.06.2014 and have done all project activities.
Please refer the below annexure for major projects handled
Proficiency Forte:
Operation, maintenance & Testing of EHV, HV, LV Substation up to 315MVA Transformer, Battery with Battery Charger, Diesel Generator etc.
Managing on-site activities to ensure completion of project within the time & cost parameters and effective resource utilization to maximize output as well as reviewing contract drawings and specifications.
Managing onsite project with manpower and maintaining all technical and non technical job.
Anchoring on-site operation,maintenance,Testing & commissioning of plants and ensuring effective resource utilization to maximize the output and reviewing engineering drawings, technical
Specifications, cost estimates for installation & commissioning and reviewing contractor's change order proposals & submittals.
SCHOLASTICS
EDUCATION:
B.Tech in Electrical Engineering from Biju pattnaik University of Science and Technology, Orissa at the year of 2012.
Intermediate in Science (10+2) from Govt. junior College, Rourkela, CHSE, and Orissa with 62% of marks.
10th from Harishankar Patel High school, Jharsuguda, BSE, Orissa with 84%.
PERSONAL DOSSIER
M.Name : Manjulata Rout
F. Name : Chandramani Rout
Date of Birth : 25 May 1989
Nationality : Indian
Marital Status : Unmarried
Languages Known : English, Hindi & Oriya
MV Licence : 10120 (MV), Govt of Odisha
Passport no : P6853707
CTC : 3.5 Lacs
Notice Period : 30 Days
Permanent Address : At- Danarkula, Post-M.D Jemadei pur, Block-Bari, Jajpur, Odisha 755017
Annexure: 1
Project:
O&M Engineer at TATA Motor, managing of 14 nos of 33/0.433KV S/s and managing man power, Street Light, Utilities.
O&M of 220/22KV Switchyard and 15 Number of 22/11/0.433 KV Substation of FIAT INDIA AUTOMOBILE LIMITED,Ranjangaon,Pune with 99.99 % Power Availability.
Operation, Maintenance & Testing of 400/220/33 KV Grid Substation at Alwar, Rajasthan under GMR ENERGY LTD.
Operation and Maintenance of 110/33/11 KV Switchyard, 5 Nos of 33/11KV S/s, 27 Nos of 11/0.433KV S/s & troubleshooting up to Energy meter under LAVASA CORPORATION LTD.
Site Engineer of 30 numbers of 33/11 KV Substation both O&M, EM&R activities at Berhampur under SOUTHCO ENERGY UTILITY, ODISHA.
O&M Engineer of 220/22KV Switchyard, 22KV GIS S/s at Utkal Alumina International Limited, Rayagada, Odisha.
Testing of all Switchyard Equipment like Tan delta,SFRA,Magnetic Balance, Vector Group, Winding Resistance, Turns Ratio, Magnetising Current,BDV,IR,CRM and Stability test etc.
Nature of work:
Maintenance of UHV, HV and GIS sub-station along with associated O/H line up to energy meter.
Maintenance of 11/0.433 KV, 33/11KV Unitization substation with Ring main system.
Detailed understanding of principle of operation of all sub-station equipments.
Erection and maintenance of HT and LT overhead line.
Overall system scheme check, auxiliary system including ACDB, DCDB, LDB, Battery & Battery Charger, fire fighting.
Preventive & Breakdown maintenance of Battery, Battery charger, UPS, D.G System associated with Relay panel, Control Panel, RTCC Panel,APFC,RTPFC Control system with responsible for Outage, tripping, complaint, Emergency attending etc.
Daily checking of all switchyard equipment.
Fixing and maintenance of 3 phase and 1 phase energy meter.
Attaining complain of Industrial and rural consumer.
Subcontractor management, quality & bill checking.
Following up with contractor & sub contractor on regular basis
Preparing monthly report and co-ordinate with client as per there requirement.
Testing of Breaker ETU, IR Testing, CRM testing, Power Analysis, Energy Meter testing activities etc.
Work Initiating by different types of Work permit like Cold, Electrical, Height, and Hot work Permit System.
Conducting TBT, Technical Training on various equipment and Safety training on Fire extinguisher, First Aid, MSDS, BBS etc.
Experience in Project:
Maintenance, Testing & commissioning of Distribution transformer up to 315 MVA and Reactor.
Maintenance of Street Light and Utilities Lighting System.
Erection & commissioning of DG set up to 500 KVA.
Maintenance, testing & commissioning of Isolator, CT, PT, CVT, CB & LA etc.
Working knowledge on 33KV Outdoor VCB of make Siemens, Areva, Stelmech, Scheineder, Bhel, EsonRyrolle etc.
Working Knowledge on 33KV Indoor VCB of ABB, Siemens Make.
Inventory register checking & sub-contractor bill checking.
Involved in Industries Plant Maintenance Activities, Safety Co-odinator, 5’S Manager and Training Activities etc.
Making Kizen in both technical and safety on existing System.
Knowledge of Computer:
Having good knowledge on MS-office, Word Excel, Power Point, Internet etc.
Declaration:
I hereby declare that the above given information is true & correct to best of my knowledge.
I have performed my duty honestly, sincerely as per company Standard and Rule.
Date: 07.06.2018 Deepak Kumar Rout
Place: Odisha