Post Job Free
Sign in

Electrical Engineer Design

Location:
Al Khobar, Eastern Province, Saudi Arabia
Salary:
8000 to 10000
Posted:
May 16, 2018

Contact this candidate

Resume:

RIZWAN SHAFIQ

*********@*****.***

Mobile:+966*********

“Highly motivated professional with excellent leadership skills. Performance-driven individual who can create immeasurable success in a team and turn complex problems into solutions.”

Summary

Profile:

Nationality:

Current Location:

Current Position:

Male, 30

Pakistani.

Jubail, Saudi Arabia

Design Engineer (Electrical)

Company: Arkad Engineering & Construction.

Saudi Eng Council

Academic

Background

Engineering in Bsc Electrical (communication)

Riphah Internation Islamabad Session March 2005-Dec 2009. Work Experience

Aug 2016-

Present

Arkad

Design Engineer(Electrical)

Jubail KSA

Projects Handled

Established in 2011 in Kingdom of Saudi Arabia. ARKAD is the Leading Engineering and Construction Company in Kingdom of Saudi Arabia.

Master Gas(MGS),pipe line project.

On shore maintain potential project.

Verification of IFA packages as per actual site conditions. Making Comments on the IFA.

Final Verification of IFC package before issuing to construction department. Verfication of MTO quantities as per actual field requirements. Prepration of Work procedures (Method of statements) for MOV,PIT,TIT,PDHMS,SSV installtion.

Preparation of As-Build Packages.

Re-evaluation of CRPO line items.

Responding Technical Queries of Construction Department. Preparation of I-Plant Drawing Packages.

Preparation of Design layout for Temporary camp facilities. Preparation of voltage drop(I2R losses) for medium voltage cables. Preparation of Single line Diagrams for Camp Facilities. Preparation of Grounding system layout for camp facilities. Preparation of Load Calculations.

Calculation of luminous intensity for security lighting and floodlights for office as well as camp facilities.

Responding to NMR'S & MTA'S with technical evaluation as per requirement. Preparation of Material Take off the list to the procurement team for raising MR'S. Sep 2014-Aug 2016 Bin Quraya Riyad, Saudi Arabia

Designation

Achievements

Electrical Engineer.

Established in the KSA since 1975, Bin Quraya is the leading Mobile Cranes and Heavy Equipment rental firm in Saudi Arabia, with one of the Middle East’s largest heavy equipment fleets. Bin Quraya also Provides the Multidisciplinary Engineering, Construction for Oil and Gas projects for Saudi Aramco.

Checking of all the materials in coordination with QC inspector whether the materials are matching standard requirement or not.

Preparation of Red lines against the IFC as per the Standard Requirement or the variations of design as per the site conditions.

Installation of wellhead control system like ESD local control stations, choke valves, RTU, well downhole dynamics monitoring system. Installation of field instruments like MOV's, PIT'S, TIT'S.

Installation of 13.8kv Over Head Power Line consisting of two feeders.

Performed all aspects of Pre-commissioning of electrical power distribution systems and instrumentation for Ethane & Methane Metering skid, Sales Gas Filter Station, Gas Wells, Oil wells, water Wells

Monitoring and Checking of all the Punch Items given by Client. The closing of Punch items.

Insulation Resistance testing of Power and Instrument cables.

Continuity testing of Power and Instrument cables.

Preparation of Instrument Loop packages for PIT's, TIT's, MOV's, FPV's, Level Switches.

Point to Point Loop Checking (Dry Loop check)

Leak Testing of Impulse Tubing of PIT's, PDIT's, FPV's.

Power Loop checking of Instruments PIT's, TIT's, PDIT's, MOV's, FPV's, Level Switches

Stroking of MOV's both locally and remote through Metering control Panel. Field Calibration of Instruments PIT's, TIT's, PDIT's, FPV's, Level Switches.

Pre-commissioning of 34.5kva power line which includes HI-POT test, IR-testing &continuity testing.

Installation of 75 kva transformer,34.5kva switchgear.

Installation & Pre-commissioning of power panels, circuit breakers, LCP'S ETC

Project details

Pre-commissioning of Cathodic protection system for oil wells, Gas wells & Water which includes amperage reading, resistance reading.

Testing of Grounding Test station, Grounding Electrodes, Earth resistance testing. Client

The Khurais project as a whole covers three oilfields: Khurais, Abu Jifan, and Mazalij. The Khurais field, with an area of 2,890km2 and 127km long, located about 250km south-west of Dhahran and 300km north south-east of Riyadh, is the biggest in the project. Abu Jifan covers 520km2 south-west of Khurais and Mazalij covers 1,630km2 south-east of Abu Jifan, intended to boost the production capacity of Saudi Arabia's oilfields from 11.3 million bpd to 12.5 million bpd.

Saudi Aramco.

TALA Al Khalij Group of General Contracting 2013-14 Designation Electrical Engineer

TALA AL Khalij Group of General Contracting is an energy and environmental engineering company based in Saudi Arabia

Project details

Client

Onshore Maintain Potential Program(Oil&Gas) Northern Area Oil Upstream Project Division NA-1 for Khursaniyah Gas Increment, Construction & Implementation of interconnection Fiber Optics OSP/ISP, Networking, CCTV, Telecom Room Preparation for Oil Wells, Remote Headers, Operator Shelters, Gas Gathering Manifold, Complete Networking distribution & 13.8kV, OHPL, Pole Mounted Transformers Scope. Saudi Aramco

Construction of 25 OSP FOC links (60KM) interconnecting Oil wells/RH/OS/GGM. Construction issues trouble shooting, managing, monitoring Project main Subcontractor NAIZAK Global Engineering Systems & others for construction field implementation and ensuring status operation of all activities according to IFC Package design and QA/QC standards

Leading, Coordinating and providing support to Saudi Aramco project management, Inspection department and project engineering team to ensure successful project implementation and to successfully meet project milestones.

OSP/ISP survey, Redlines drawings, design updating, making Google Kmz files for all links, inspecting Material take off list (MTO) items matching with IFC package & drawings, updating record, project delivery life cycle, monitoring Progress, enforcing Procedure

Preparing various progress reports, technical proposal evaluation, multiple associated Remote Terminal Unit ( RTU )

Pre-Communication and Loop Checking of RTU and Field Instrument’s like FIT,PIT,TIT,FM.MOV Commission the RTU to SCADA master station,with Antenna Achievements

Electrical system of Fence Lights

Installation, termination and testing of street light pole, 5 meters height, IP-66, Model VOLO-1581-SAP-T-150, 208V, 60Hz with bulb.

Erection of 5 meters long hot dipped galvanized poles, tarpapered, powder coated and silver finished (RAL-9006) with fixing accessories (Bas Plate, Anchor Bolts, Support Brackets and etc.) Installation, Connection and Testing of Ground Rod & PIT Over Head Power Line & Upgrade Of Sub-station

Installation of 13.8KV Over Head Power Line 55FT Pole including Cross Aram, Suspension Insulator, Post Insulator, Surge Arrester, Cutout Fuse, Transformer ( 150 / 100/ 75 / 25 / 15 kVA,13.8kV/480V-240V ), MCCB

ELECTRICAL EQUIPMENTS

. Transformer: 1000KVA Pad Mounted 13.8KV Primary, 400/230V

Ring Main Unit (RMU) & Kilowatts Hour Meter

Installation of Electrical mounting Rack (EMR) with Distribution Panels & Dry Type Transformer ( 5kVA), Lighting Contactor Panel( LCP )-480V,1Ph,60Hz

Installation of Grounding Cable, Rod with thermite welding & PIT As per Aramco Standard &Testing & Termination

Main Distribution Panel board(MDPB-1): 225AT/AF; 400/230V, 3 Phase, 4W, 36 Ways NEMA 1 Enclosure.

Lighting Fixtures: Recessed Mounted/4x32W,T8,220V,electronic ballast NLCP50432E6,

Fire Alarm & Detection System: Installation, Testing, Commissioning & Designing of Shop Drawing & as built drawing as per contract ( System :: EDWARDS )

Security Access Control System:

Access Control Panel: Security Access Control Panel/220VAC/Model M2 By Hirsch Electronics, Power Supply With FA Module/220VAC/Model PS902/900-FA

Access Control Device: Electromagnetic Lock/Model MA490P By Locknetics, Exit Push Button/Model 625RD EX-DP by Locknetics, Card Reader/Model CR-SCM-CCL-H by Hirsch Electronic, Key Switch/Model 653-NS by Locknetics, Alarm Line Module Model DTLM2 by Hirsch ELECTRONIC,

Testing & Commissioning System Hirsch ELECTRONIC Job

Responsibilities

Coordination with PMT & fulfill all his requirements

Making of Access of all teams & also coordinating with Armco Security for making Work permit.

Check the Safety & work permit issue & resolve them

Daily reporting to client regarding actual values

Weekly & Monthly reporting to management & Client.

Coordination with management regarding RED LINE drawing & submit to PMT

Responsible for all Quality Control activities for the allotted area of discipline

Familiarization with overall construction scope of work.

Site surveillance to check the construction work and give comments if necessary, according to standard.

Conduct internal inspection among all activities and record inspection findings. .

Engineering standards and procedures and applicable national and international codes and standard & Coordinate with QC.

To prepare request for inspection for client inspection for completed activities

Preparation of Material Take over List, Material Transfer request. Training and Experience

Company: Al Ghaiz contracting Company ( Dec2009 - Jan2013) Achievements

An analytical study with special focus on Designs and Working of Generators, Gas turbines, Control Systems. A study of the company as a whole, their different departments, their production process, and a special focus on the marketing strategies adopted by them and based on the information collected recommend some suggestions for improving their marketing strategy.

I’ve 9+ Years of Experience in Electrical, instrument & communication Field, Special in KSA, 5 years Experience with ARAMCO Projects

Competencies

Languages English (excillent), Urdu (fluent), Arabic (basic). Technical skills

Microsoft Office, Microsoft Excel, Microsoft word, Auto Cad, Micro station Primavera-p6, E-plan.

Declaration

I hereby declare that the above mention details are true and best of my knowledge



Contact this candidate