CURRICULUM VITAE
E-mail id: **********@*****.***
Mobile No: +91-807*******
OBJECTIVE:
Utilize my skills and abilities to have a dynamic, challenging & rewarding career in an organization where I can have the opportunity to excel professionally. PROFILE:
About 4.9 Years of total experience in Electrical Engineering Field in Power system protection & control in the field of Testing and Commissioning of protection, control, Relays, Switchgear for Substations (400,380,132, 33,13.8 and 6.6 KV Levels), Electrical protection Schemes/Functional systems testing, Relay and Control panels Testing. Operation and Maintenance of Electricity Distribution System, Testing and Maintenance of Automated Test Fixtures. PROFESSIONAL SKILLS:
Experience in Testing and Commissioning of power system protection relays and control system.
Knowledge of SLD (Single Line Diagram), ANSI codes and symbols.
Interfacing of Protection and Control system with primary Equipment’s.
Design and Testing of Interlocking schemes, control and alarm schemes, OHL, Transformer and Breaker failure schemes.
Knowledge of operating the primary and secondary injection test kits like Omicron 256,Omicron 356,Doble F6150,Megger SMRT36,Punova,CPC 100,Winding Resistance Kit(SCOPE),Contact Resistance and Timing Meter(SCOPE), HV Test Kits and have some hands on experience on Omicron.
Testing of Protection Functions like Distance protection, scheme communication protection, Line Differential protection, Transformer Differential protection (High Impedance/Low Impedance), REF protection etc.
Knowledge in trouble shooting of protection and control schemes as well as Functional and Scheme testing of the Protection, Control and Switchgear panels.
Knowledge of configuring protection IED’s for Control/Alarms functions for the purpose of integrating with SAS systems and performing Local/close loop tests in co-ordination with SAS team.
Testing of CT”s, PT’s,Transducers, Multifunction meters, Energy Meters and all types of Digital Meters
Conducting High Voltage Tests for MV and LV Switchgear Panels, HV & MV Power Cables and Switchgear equipment’s.
2
EXPERIENCE DETAILS :( Starting from June 2013 till now) COMPANY: M/S VOLTECH ENGINEERS PVT LTD
Position Held : Protection Engineer.
Duration: Since June 2013 to November 2015
COMPANY: M/S SYNERGY POWER CO (Saudi Arabia)
Position Held : Protection-Testing and Commissioning Engineer. Duration: Since January 2016 to January 2018
Roles and Responsibilities:
Providing the solutions for the protection system and to enhance the support for the substation control system.
Preparing the protection logic diagram & protection philosophy for the applicable bay along with the interlock logics as per requirement.
Revising the scheme against client comments received from SEC/Consultants.
Preparing the Protection relay & BCU I/O list as per the application.
Review of protection relay setting calculation.
Adapting the setting calculation for the relays provided by Customer/Consultant.
Furnishing the test reports to the customer after completion of the testing & witnessing process.
Working in energized S/S during retrofit jobs without causing interruption to the system while performing modification activities on existing schemes.
Testing of CT”s, PT’s,Transducers, Multifunction meters, Energy Meters and all types of Digital Meters
Functional and Scheme testing of the Protection, Control and Switchgear panels.
Conducting High Voltage Tests for MV and LV Switchgear Panels, HV & MV Power Cables and Switchgear equipment’s.
Co-ordinate and planning the testing activities with Customers (Witness) and planning the activities according to the schedules on a regular basis.
Supervising the Commissioning activities of the site like Cable schedule verification, material requirements, Design related issues and follow up for any Clarification issues with the factory.
Planning and managing all site activities and conducting Meetings with Various customers and Suppliers.
Providing technical training to the engineers.
TESTING AND CONFIGURATION OF RELAYS:
Testing and commissioning of following substation Protective and Control Relays. TYPE MAKE SKILLS
REF620, REF610, REF615,
RED615, REL670, REL650,
RED670, REM615, RET670,
RET615, REF542, REF543,
SPAJ140, SPAJ160, SPAU130,
SPAF140C.
ABB
Configuration and Testing of ABB make
relays using Omicron Test Kits.
Configuration of relays using PCM 600 –
(Version 1.5,2.0, 2.2, 2.3,2.4,2.5 ).
7UM622,7UT612,7UT613,
7SJ622,7SJ624,7SJ81,7SJ645,7SJ
802,7SJ80, 7SK804,7SK802
SIEMENS
Configuration of relays using DIGSI
software.
-(Version 4.81 to 4.89 ).
F650, D60, T60,MIV-II & MIV-II.
GE
Configuration of relays using F650,UR
RELAY software.
3
P546,P442, P443,P444,
P343,P220,P222,P243,
P241, P632,P633,P642,
P111,P123,P122,P127, P141,
P142,P143, P145, P545,
P643,P921
ALSTOM/
AREVA
Configuration of relays using Micom
Studio, Agile software.
SEL 751.
SEL
Configuration of relays using SEL
AcSELerator Quick SET Parameter
Tool.
T42, M42, S40&S42.
SEPAM
Configuration of relays using SFT2841
software.
-(Version 16.0 ).
List of some of the Projects where worked:
Middle East - Saudi Arabia
Project Name Customer Nature of Job
Testing of 132KV
EHV Protection Panel
& Relays for 8783 SEC
substation at Wadi al
Dawasir,Saudi
M/S NOOR
COMMUNICATION
LTD.
Configuration and testing of protective
relays ( RED670,RED615,REC670,P545 )
Functional Checks for two bays and
LCC panels.
Testing of
Control panel for
380/110/13.8 KV
substation at SWCC
WATER PLANT at
Jeddha,Saudi
M/S AL-TOUKHI
COMPANY.
Configuration and testing of protective relays
(REF615 ABB feeder protection relay)
Testing of auxiliary relays (RXMS1,
RXSF,RXMD,RXKL,etc).
Testing of CT testing and loop check.
Testing of metrosils,
MCB’S,Contactors&Timers.
Scheme check for switch gear.
Testing of
Control panel for 110/13.8
KV substation at JEDDHA
NEW PORT at
Jeddha,Saudi
M/S NESMA
ELECTRIC
COMPANY.
Configuration and testing of protective relays
(P141 ALSTOM feeder protection relay)
Testing of auxiliary relays (MVAX,
MVAJ,RXMS1,RXSF1,RXKL,etc).
Testing of CT,VT& VCB.
Scheme check for switch gear
Testing of
MV and LV Switch
Gear Protection
Relays for 4.16 and
13.8 KV substation at
Al QassimPower plant
at Qassim,Saudi
M/S NCC CO. Configuration and testing of protective relays (argus 7S110 feeder relay )
Testing of VCB, VT’S,busbar, Cable
and MFM meters.
Testing of
MV Switch Gear
Protection Relays for
13.8 KV Switch gear
at 8055 SEC
substation at Riyadh.
M/S Siemens. Testing of protective relays (MCGG11
ALSTOM feeder protection relay).
Testing of VCB.
4
Erection and Testing
of
MV Switch Gear and
Protection Relays for
13.8 KV substation at
SAGO at Jizan,Saudi
M/S Schneider
Electric.
Configuration and testing of protective
relays (T40 Sepam feeder relay )
Testing of VCB, VT’S,busbar, Cable
and MFM meters.
Testing of
MV Switch Gear
Protection Relays for
13.8 KVand 33 KV
substation at Almarai
milk farm at Alkharj.
M/S Schneider
Electric.
Configuration and testing of protective
relays (P546&T40 Sepam feeder relay )
Testing of VCB,and MFM meters.
Functional Checks for all switchgears.
Testing of 13.8 kV
Capacitor bank for
115/13.8kV
Mardumah(RC)
substation at
Jubail,Saudi
M/S Hadi
Haider
Co
Erection inspection of capacitor bank.
Testing of capacitors, reactors and
NCT’s (5 units)
Testing of
MV Switch Gear
Protection Relays for
4.16 KV substation at
KAPSARC at
Riyadh,Saudi
M/S
ELSIEF(ARAMCO)
CO LTD.
Configuration and testing of protective
relays (T40,M42&MLJ SYNCH feeder
relay )
Testing Cable and MFM meters.
Testing of 13.8 kV
Capacitor bank for
New 33/13.8 KV
skaka
industrial substation
at Al-Jouf,Saudi
M/S TAQQAT
GLOBAL CO LTD
(ALHAITAM).
Erection inspection of capacitor bank.
Testing of capacitors, reactors and
NCT’s (2 units)
Testing of
33 KV Transformers
at Almarai milk farm
at Alkharj,Saudi
M/S Schneider
Electric.
Testing of Two Power transformers.
Testing of
MV Switch Gear
Protection Relays for
13.8 KV substation at
IMAM SAUD
UNIVERSITY at
Riyadh,Saudi
M/S SAUDI
BUILDING
MAINTANANCE
CO LIMITED.
Configuration and testing of protective
relays (7SK Siemens feeder protection
relay)
Testing of VCB, Transformer and
Cable.
Testing of
MV Switch Gear
Protection Relays for
13.8 KV substation at
PRINCES NOORAH
UNIVERSITY at Riyadh.
M/S SAFARI CO
LTD.
Configuration and testing of protective
relays (T40 Sepam feeder relay )
Testing of VCB, Transformer,busbar,
Cable and MFM meters.
5
Testing of
MV Switch Gear
Protection Relays for
13.8 KV substation at
MILITARY OF
INTELLIGENCE
CAMPUS at
Riyadh,Saudi
M/S AN-NASBAN
GROUP.
Configuration and testing of protective
relays (REF615 ABB &T40 Sepam feeder
relay )
Testing of VCB,Transformer,Cable and
MFM meters.
Testing of
LV Switch Gear
Protection Relays for
Distribution
substation at Saudi
Arabian Monetary
Authority at
Riyadh,Saudi
M/S SAMA (GOV).
Configuration and testing of protective
relays (P142 Schnider &T41 Sepam
feeder relay )
Testing of ACB,Transformer and MFM
meters.
Across - India
Project Name Customer Nature of Job
Testing & Pre Commissioning of
MV Switch Gear Protection Relays
for 66/11 KV substation at
CAIRNOIL&GAS PLANT at
Barmer,Rajasthan
M/S CAIRN
ENRGY
LIMITED.
Configuration and testing of protective
relays (P442, P141, REF615, RET642)
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33 KV TPCIL S/S at
Nellore,
ANDHRA PRADESH.
M/S BGR
ENERGY
SYSTEM
LTD.
Configuration and testing of protective
relays (P632,P442,P440,P343,P127) in
2*660 MW Thermal Power Plant
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 400KV/132KV NAVA BHARATH
GENARATING S/S at Pollanchi,
ANDHRA PRADESH.
M/S NAVA
BHARAT
VENTURES
LIMTED.
Configuration and testing of protective
relays (REL650,P444,RET615) in 4*60
MW Thermal Power Plant
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV JK TYRES LIMITED,
Sriperampudur(CHENNAI)
M/S
Siemens.
Configuration and testing of protective
relays (7SA61,7SJ80,7SR011) in
132/33KV Substation at JK TYRES
LIMITED
Testing & Pre Commissioning of
Control&relayPanel Protection
relays @ 132KV/11KV ADITHIYA
UTKAL ALUMINA S/Sat Dikri,
Orissa
M/S ABB. Testing & Commissioning of protective
relays (REM545,RET670,7SJ80,
7UM622) in 3*60 MW Captive Power
Plant
6
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/11KV at AMTEK INDIA
LIMITED,
Raipur (Chhattisgarh)
M/S
Schneider.
Configuration and testing of protective
relays (P442, P643, P142) in 30 MW
Solar Power Project at AMTEK INDIA
LIMITED
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV at CHUZACHEN
HYDRO ELECTRIC PROJECT, East
Sikkim
M/S GATI
INFRA PVT.
LTD.
Configuration and testing of protective
relays (P741, P742, P343, P633, P442,
P122, P921, P141) in 2*55 MW Hydro
Power Project
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV S/S at GSPC ltd,
Yanam (Pudhucherrey)
M/S GE
POWER
LIMITED.
Configuration and testing of protective
relays (GE350SR,MIV 2,MIV 2) in
132/33KV Chndel Substation at
GUJRATH STATE PETROLUM
CORPORATION
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV S/S at TATA
STEELS LTD, Orissa
M/S
VOLTAS.
Configuration and testing of protective
relays (P632, P141, P127, P122) in
132/33KV Substation at TATA STEELS
INDIA LTD
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV S/S at TECNO
PARK, Kollam,Kerala.
M/S
SIEMENS.
Configuration and testing of protective
relays (7SG 18,7SA522, 7UT613) in
132/33KV Substation at KERALA
ELETRICITY BOARD
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/11KV S/S at TATA
STEELS LTD, Orissa
M/S LINDE
LIMITED.
Configuration of protective relays
(7SJ645, 7UT612, 7SD610,7SA522,
7UT613, 7SJ80) in 132/11KV
Substation at TATA STEELS LIMITED
Testing & Pre Commissioning of
MV Switch Gear Protection Relays
for 6.6KV&11 KV substation at
INDIAN OIL CORPORATION LIMITED
at PARADEEP, Orissa
M/S
ROHINI.
Configuration of protective relays (
7SK804, 7SK802, 7SJ803,7SJ802,
7SJ622,7SJ624, REF625, REM615,
RET615, P141,P143,P241) in 6.6KV &
11KV Switch gear at INDIAN OIL
CORPORATION LIMITED
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@ 132KV/33KV S/S at ZF PLANT
LTD, Coimbotore,
Tamilnadu.
M/S
SWITCHERL
AND CO.
Configuration and testing of protective
relays (REF615, REM615,RET670,REX) in
33/11KV Substation at ZF PLANT LTD
7
Testing & Pre Commissioning of
LV Switch Gear Protection relays
@66KV/11KV S/S at TATA STEELS
LTD, Orissa
M/S
THERMAX
LIMITED.
Configuration of protective relays (REF
615,SEL 750,SEL 710) in 132/11KV
Substation at TATA STEELS LIMITED
Testing & Pre Commissioning of
MV Switch Gear Protection relays
@132KV/11KV S/S at TATA STEELS
LTD, Orissa
M/S
FLAKTWOO
D LIMITED.
Configuration of protective relays (REF
615,RET 670,REF 630 ) in 132/11KV
Substation at TATA STEELS LIMITED
Testing & Pre Commissioning of
CRP Panel Protection relays
@132KV S/S at TATA STEELS LTD,
Orissa
M/S
SIEMENS.
Configuration of protective relays
(7SA522,7SA611) in 132KV Substation
at OPTCL BOARD
Responsibilities:
Handling project activities involving working out various requirements with respect to utilities, manpower& monitoring overall project operations for ensuring timely completion.
Managing resources to perform project activities in cost effective manner.
Dealing with consultants/ licensors/ statutory bodies for compliance of requirements.
Ensuring proper inventory control on the spare parts and their replacement.
Identifying areas of obstruction/breakdowns and taking steps to solve the problems in an effective manner.
Executing cost saving and energy saving techniques/ measures and modifications to achieve reduction in O&M expenditures and work within the budget. I have worked in in QC Division for Relay and Control panel Testing Department in Substation and Automation Division. I have experience in testing different types of Relays such as Numerical Relays, Microprocessor Relays, Static Relays and Electro-Mechanical Relays. Tested all types of protection Systems such as Line protection, Feeder protection, Transformer protection and Generator Protection. Tested Different types of Control Panels with CT, PT injection Metering, Control Circuits and Functional Systems.
Key Skills:-
Testing of Relays and Control Panels for various protection systems such as Line Protection, Feeder Protection, and Transformer Protection & Generator Protection.
Testing of Numerical and Electro-mechanical relays.
Able to read Single line Diagram and perform the testing of protection systems.
Schematic level testing of Relay and Control panels.
Incoming (QA/QC) Quality material inspection and testing.
Handling customer inspection and testing activities. 8
Academic Performance:
Examination Passed Institution
Year of
Passing
Class & % of
Marks
Professional Qualification:
B.E in Electrical &
Electronics Engineering
Diploma in Electrical and
Electronics Engineering
Anna University, Tamil
Nadu.
St. Xavier’s Polytechnic
College
Seydunganallur,Tamil Nadu
April 2013
April 2010
64.66
68.75
Trainings Details:
Undergone one week training on Transformer Manufacturing and Testing in Alfanar transformer factory.
Undergone one Month training on Numerical Relays Testing in VTC -CHENNAI
The training covered all the numerical relay makes: ABB, SIEMENS and ARIVA. PERSONAL PROFILE:
Name : K.MOHIDEEN GNANIYAR
Father’s Name : M.KAJA MYDEEN
Date of Birth : 29/06/1992
Gender : Male
Marital Status : Single.
Nationality : Indian.
Passport : Passport No: R8929030,
Issue date: 15/02/2018, Valid till 14/02/2028.
DECLARATION:
I hereby declare that all the information stated above is true to best of my knowledge and belief.
Thanks & Regards,
K.MOHIDEEN GNANIYAR