Post Job Free
Sign in

Engineer Mechanical

Location:
Pakistan
Salary:
7000
Posted:
April 29, 2018

Contact this candidate

Resume:

P a g e * *

HAFIZ SANA ULLAH

Mechanical Engineer

Contacts: -

House No-3, Near Al-Khadeeja Degree College, Khayaban-E-Mustufa, Mari Indus, Tehsil & District Mianwali, Punjab - Pakistan Cell: +92-333-*******

E-mail: *******@*******.***

Career Objective: -

To be the part of a successful team of skilled and committed professionals engaged in the field of Mechanical Engineers, who can set and achieve targets at any conditions. Thus to invest efforts and skills to the completion of the projects, which can offer growth and satisfaction in career. Devotion, dedication and honesty are the top most requisites of success in life, by following these I would like to become valuable and viable part of Organization.

Personnel Information: -

Father’s Name: Amir Abdullah

Date of Birth: November 2, 1986

CNIC No: 38302-9676420-7

Domicile: Punjab

Nationality: Pakistani

Marital Status: Married

Religion: Islam

Qualification: -

2010 – 2012

Bachelor of Technology in Mechanical (Hons)

Preston University Islamabad, Pakistan.

3.3GPA

2008 – 2010

Bachelor of Technology in Mechanical (Pass) Preston University Islamabad, Pakistan.

3.5GPA

2005 – 2008

Diploma of Associate Engineer in Mechanical

Punjab Board of Technical Education Lahore.

75% Marks

2001 – 2003

Matriculation (Science)

Board of Intermediate and Secondary Education Sargodha 49% Marks

P a g e 2 6

Experience Synopsis: -

I have completed the graduation (B. Tech Hons) in Mechanical from Preston University. Recently I am working as a Junior Engineer Mechanical being representative of Associated Consulting Engineers

(ACE) to render consultancy services for Neelum Jhelum Hydro-Electric Power Project of Capacity 969 MW, Run of the River, Pakistan first Under Ground Hydro Electric Power Station with Total Tunnel Length of 65.5 Km. Neelum Jhelum Hydropower Station comprises on 4 Vertical Axis Francis Turbine

(243.25 MW each) at rated head 370m.

I have almost 9+ years’ professional experience in Supervision, Installation / Erection, Testing and Commissioning of Hydropower Stations, Auxiliary Equipment, Turbine & Generator, Hydraulic Gates Steel Structure, Pipeline, Over Head Bridge Cranes and HVAC System. I supervised the Contractors during the execution of construction activities at a fabrication yard Participate in reviewing detailed design drawings method statements material requisitions and Co-ordination. I have a good level of computer literacy and proficient in all version of Microsoft Office, Microsoft Windows, and CAD. I have excellent communication and presentation skills in both written and verbal English.

I learnt the technical knowhow of this line of work and actively participated with the full team of Consultants and Contractor, under the able guidance of my superiors in activities related to Quality Control, Quality Assurance, Commissioning of Project and General Supervision of the works for implementation of miscellaneous Power Projects.

Professional Experience: -

1. NEELUM JHELUM HYDROPOWER PROJECT – MUZAFFARABAD-AJK Employer: ASSOCIATED CONSULTING ENGINEERS(ACE)

Client: WAPDA

Contractor: CMEC & CGGC

Position Hold: Junior Engineer Mechanical

Period: January 2014 To Till Date

Project: Neelum Jhelum Hydropower Project, Muzaffarabad - Pakistan Engineering Code: Power Engineering

As Inspector Mechanical working with Neelum Jhelum Consultants Joint Venture of MWH (U.S) Norplan

(Norway), NDC (Pakistan), NESPAK (Pakistan), ACE (Pakistan). I am responsible to render consultancy services for Neelum Jhelum Hydropower Project of Capacity 969 MW, Run of the River, Under Ground Hydro Electric Power Station with Total Tunnel length of 65.5 Km comprising of 4 Vertical Axis Francis Turbine (243.25 MW each) at rated head 370m. The Project envisages the diversion of Neelum waters through 28km tunnels at Nauseri to Chattar Kallas where the Underground Powerhouse is located. Considerably contributed for various important decisions at site, assisting resident engineer in various matters, effective co-ordination with Client & Contractors. Office Based Responsibilities: -

Effectively handling Yearly, Quarterly, Monthly, Weekly and Daily Progress Reports and Presentations.

P a g e 3 6

Drawings Reviews & Quantity Survey.

Assisting Resident Engineer and Assistant Resident Engineers in reviews of Method Statements and other activities.

Timely drawing co-ordination with civil & electrical department on various issues.

Evaluate Scope of Work, Bill of Quantities (BOQ). Specification & drawings, Conditions of Contract.

Preparation of Reports for Daily Based Inspections. I have been assisting my superiors for issuing NCR, FCR, and DCN

Technical / Site Based Responsibilities: -

Supervised the installation of Bonneted Gate, Draft Tubes, Spiral Case (ø2600mm), Distributor Assembly including Wicket Gates, Head Cover and Bottom Ring Labyrinth Rings and their Associated Checks and NDT performed by Contractor.

Examined the Spiral Case Hydrostatic Pressure tests carried out at 7.425MPa (1.5% of Nominal Pressure)

Supervised the manufacturing (by rolling of plates Thickness up to 42mm and varied dia from ø2600mm toø4200mm) and installation of Penstock segments (of Length 6m) of Mild Steel along with associated NDT and sand blasting, painting and cement wash.

Supervised the assembly and installation of Main Inlet Valve of ø 2600mm to control the flow of water for generating unit.

Monitored the punching / Pressing of Stator Flabellate Sheet for Hydraulic Generator and Rotor and witnessed the associated Tests performed by Contractor.

Supervision of Fabrication, Welding, Installation and Hydrostatically Pressure Testing of Stainless Steel and Mild Steel Pipes up to ɸ 577mm at 1.5% of their design pressure for Unit Auxiliary Systems

(Compressed Air, Lube Oil, Cooling Water Supply & Drain, Fire Fighting, HVAC and Tunnel Dewatering etc.

Successfully supervised the installation and commissioning of two bridge cranes of capacity 275x30 Tons installed for erection and maintenance of units. Commissioned the 100T & 45Tons Bridge Cranes Installed for handling of penstock at C-2.

Supervising the Survey of Overhead Bridge Crane 270x30Tons to know the impact of convergence of powerhouse. I have supervised the all Temporary and permanent re-settings carried out by Contractor.

Successfully commissioned the 5-ton overhead crane for installed for erection of GIS system.

Inspection of incoming materials, Mechanical parts and Assemblies; mark and complete appropriate documentation to assure compliance with P.O. requirements and specifications.

Records test results and inspection data, and compares findings with specifications / drawings to assure quality and completion of Project.

Supervised Installation of hanging structure and false Ceiling (Corrugated Sheet Type)

Read and Analyze Drawings, Manuals, Verify Measurements of Mechanical Equipment, and Test the Ascribed Capabilities record and maintain inspection and test records.

Supervise & monitored the welding team during different welding processes (1G, 2G, 3G, 4G), Checking the quality of welding by applying NDT methods (Ultrasonic Testing, Radiographic testing and DPT).

Supervised and approved construction activities and co-ordinated various aspects of project construction including inspections, material submissions, drawings and processing documentation P a g e 4 6

as required. I Handled all aspects of Mechanical Construction activities including site investigations site surveys.

Supervised work anomalies or contractual deviations committed by contractor and recommend corrective actions Via FCR, NCR, or DCN

2. JINNAH HYDROPOWER PROJECT – KALABAGH - MIANWALI Employer: ASSOCIATED CONSULTING ENGINEERS (ACE)

Client: WAPDA

Contractor: Dongfang Electric Corporation

Position Hold: QA/QC Mechanical Inspector

Period: June 2011 to September 2013

Project: Jinnah Hydropower Project, Kalabagh–Pakistan Engineering Code: Power Engineering

As Inspector Mechanical worked with Jinnah Hydropower Management Consultants has assigned the responsibilities for the supervision of eight (8) Hydal units of Kaplan Pit Type Horizontal Shaft Turbine installed at Jinnah Hydropower Project of Capacity (12 8) 96 MW at Kalabagh District Mianwali. It is located along the right side of the Jinnah Barrage. Responsibilities: -

All associated auxiliary system power plant such as Cooling Water System and Water Treatment System of Drinking Water, Power Plant Supply, Lubrication System of Bearing, Compressed Air System including Medium and Low Pressure for Turbine Governor System and Unit Braking System, and HVAC System etc.

Supervised the installation of Trash Racks, Trash Rack Cleaning Machine (TRCM) and Gantry Cranes for handling of Stoplogs at Upstream and Downstream of the power house embedded parts of Stoplogs.

Supervised the Dry and Wet the Commissioning Tests of the units, Stabilization of the Temperatures of the unit, and Load Rejection Tests, performance of units for 72 Hours and 30 Days Reliability Run

(at Full Load) of each Unit. Recorded all necessary data during all above mentioned tests and witnessed the Over Speed Trip Test of the unit.

Prepared the punch list of deficiencies of Mechanical works.

Daily Progress Report at site to project team.

Carried out the inspection and witnessed the Non Destructive Testing (NDT) of field welds of the turbine structure and parts

Moreover, carried out incoming examination of the material and parts approved at site as per their packing lists.

Participated in the development of as-built drawings documentation.

Prepare Punch list for finished work prior to hand over to the client by the contractor by paying special attention to all equipment including Quality checks.

Liaised with the HSE Supervisor on safety related matters. 3. NEW BONG ESCAPE HYDRO ELECTRIC COMPLEX – MIRPUR-AJK Employer: Andritz Hydro Limited

Client: Laraib Energy Limited

P a g e 5 6

Contractor: Andritz Hydro Limited & & Sambu Construction Co. Position Hold: Mechanical Supervisor

Period: 30 December 2010 To 25 June 2011

Project: New Bong Escape Hydro Electric Complex, Mirpur, Azad Kashmir Engineering Code: Power Engineering

As Supervisor Mechanical worked with Andritz Hydro Limited and had assigned responsibilities for the supervision of Four Hydal units of Kaplan Bulb Type Horizontal Shaft installed at New Bong Escape Hydro Electric Complex of Capacity (21 4) 84 MW at Village Lehri, Tehsil and District Mirpur. Responsibilities: -

Supervise the installation of auxiliary system such as Cooling Water System and Water Treatment System of Drinking Water, Dewatering System of Units, Power House Drainage System, all type of embedded parts, Stop Logs Embedded Parts and Frames.

Participated in installation of major parts of Turbine such as Draft Tube Liner, Stay Ring Assembly, Stay Columns, Pit Liner, and Embedded Piezometer Lines for recording of Head Race, Tail race and Trash Rack Differential Heads.

Also participated in testing carried out at site such as Ultrasonic Test and Dye Penetrant Tests of the several welding joints of Kaplan Turbine parts. Moreover, I took part in Hydrostatic Pressure Tests carried out at Dewatering and Drainage Pipe Lines of the power house.

Prepared daily progress report at site to project team. 4. JINNAH HYDROPOWER PROJECT – KALABAGH-MIANWALI

Employer: ASSOCIATED CONSULTING ENGINEERS (ACE)

Client: WAPDA

Contractor: Dongfang Electric Corporation

Position Hold: Associate Engineer Mechanical

Period: 09 July 2008 To 29 December 2010

Project: Jinnah Hydropower Project, Kalabagh–Pakistan Engineering Code: Power Engineering

I worked with Contactor Dongfang Electric Corporation as Associate Engineer Mechanical with work responsibilities for the supervision, construction and erection of eight Hydal units of Kaplan Pit Type Horizontal Shaft Turbine installed at Jinnah Hydropower Project of Capacity (12 8) 96 MW at Kalabagh District Mianwali.

Responsibilities: -

Carried out fitting and fabrication of all types of Embedded Parts, Embedded HVAC Ducts, Embedded Water Supply Pipelines, Unit Dewatering and Drainage Pipelines, Stoplogs Embedded Parts and Frames, Embedded Pads for the Trash Racks,

Supervised the installation of Turbine major parts such as Draft Tube Liner, Stay Rings, Stay Columns, Pit Liner and their embedded parts, Water Distribution Assembly and Runner Hub and Servomotor Assembly.

Supervised installation of two Over Head Bridge Cranes Capacity of 125 32 10 tons and 75 20

5 tons for erection of major components of turbine and maintenance of units. P a g e 6 6

Supervised the Auxiliary System such as Cooling Water System and Water Treatment System of Drinking Water, Pipelines for Lubrication System for Bearing’s Oil of Turbine and Generator, Compressed Air System Pipelines, HVAC System and Pipe lines for Fire Fighting System.

Also supervised the installation of Piezometer Lines for recording of the Head Race, Tail Race and Trash Rack Differential Heads.

Skills / Expertise: -

Information & Technology:

Operating Systems: Proficient in all versions of Windows Expert

Letter Writing: MS Word Expert

Spread Sheets: MS Excel Expert

Presentation: MS Power Point Expert

Designing: Auto Cad 2010 Expert

Technical / Professional:

The Ability to Work Under Pressure Problem Solving

Interpersonal Verbal and written communication

Commercial Awareness Team Working

Maintenance & Repairing Technical Support

Technical Writing Testing & Commissioning

Languages: -

English Fluent (Speaking, Reading & Writing)

Urdu Proficient (Speaking, Reading & Writing)

Saraiki Mother Tongue

Chinese Basic or Beginner

Awards: -

I have declared the best member of ANDRITZ Technologies limited and awarded at outstanding performance for the month of May 2011 by the Administration of the ANDRITZ Hydro Limited References: -

Muhammad Nisar Malik (Resident Engineer Mechanical) Email: *********@*****.***

Khawaja Muhammad (Assistant Engineer Mechanical)

Email: *******.**********@*********.***

Certification: -

Certification: I, the undersigned, certify that to the best of my knowledge and belief, that this bio-data correctly describe me, my qualifications and my experience. I understand that any willful misstatement described herein may lead to any disqualification or dismissal, if engaged



Contact this candidate