Post Job Free

Resume

Sign in

Management Service

Location:
Visakhapatnam, AP, India
Salary:
5000
Posted:
April 25, 2018

Contact this candidate

Resume:

KRISHNA KANTH

: +919*********

: ac48u8@r.postjobfree.com

FACILITY MANAGEMENT & BUILDING AUTOMATION SYSTEM PROFESSIONAL

Skilful in implementing procedures / control systems for maintaining quality standards; leading efforts for streamlining processes and generating cost savings in operations

PROFILE SUMMARY

Experienced Building Manager who is an expert in public and industrial safety with preventative mind- set against Fire & Electrical Hazards, Carpentry & Plumbing; Circuitry & Wiring as well as Water Management & Treatment System

Last associated with Bilfinger Facility Service, Dubai, UAE as BMS/SCADA Operator; skillful in operating & maintaining Building Management System (BMS) for proper function and monitoring against approved benchmarks to include HVAC, Lighting, Security, Fire Suppression, Power Generation, Plumbing & Electrical

Expertise in negotiating & finalising service agreements with reliable contractors for execution of servicing works as per budgeted parameters

Skilled in maintaining documentation for all malfunctions, repairs, maintenance, or changes to systems and/or equipment. Comfortable working in industrial settings; able to work well with diverse personalities

Proficient in communicating regularly with senior management to ensure accuracy, consistency, problem solving and on-time project completion

Impressive communicator with honed interpersonal, team building, negotiation and analytical skills

CAREER CONTOUR

Oct’15-Dec’17: Bilfinger Facility Service, Dubai, UAE as BMS/SCADA Operator

Oct’12-Mar’15: Kharafi National LLC, Abu Dhabi, UAE as IBMS/SCADA Operator

Oct’11-Sep’12: Apollo Power System Facilities Management, Hyderabad, India as IBMS Executive (Client: IVY Comptech Ltd.)

Apr’10-Sep’11: Kelly Facilities Management, Hyderabad, India as IBMS Executive (Client: Wipro Technologies, Hyderabad)

Sep’08-Mar’10: Randstad Facilities Management, Hyderabad, India as BMS Executive (Client: Indian School of Business, Hyderabad)

Apr’07-Aug’08: VRVS Facilities Management, Hyderabad, India as H.V.A.C. Technician (Client: Wipro Technologies, Hyderabad)

Mar’04-Mar’07: K.S. Enterprises, Vijayawada as H.V.A.C. Engineer

Key Result Areas:

BMS & Facilities Management

Looking after operations, repairing & maintenance of the building in a professional and diligent manner; ensuring fulfilment of occupants/customers obligations under the lease agreement of the space in the building

Operating & maintaining IBMS System Water & Air Cooled Chillers, CSUS, FAHU, RAHU, S AHUs, VAHU,S FCUs, Precision, Cassette, Floor Mounted Units, HRW, HRW Supply & Exhaust, Units, Staircase Preassiutions Fans, STP, WTP and Pumps

Purchasing all equipments, tools, appliances & materials viz. consumables &supplies reasonably necessary and desirable for the maintenance of the building

Monitoring fire detection alarm system, such as smoke detector, heat detector, sprinkler & emergency exit alarm; water tank supply level alarm, air handling unit, kitchen exhaust fan and fresh air handling unit

Forecasting yearly budget as well as ensuring allocation of budget in CAPEX documents; overseeing documentation towards CAPEX requirements

Managing complete interior, electrical, data cabling and civil work in coordination with all these vendors

Supervising & maintaining (AMCs - Annual Maintenance Contracts) for AC, UPS, Inverter, Stabilizer, Server Room Procession AC, Machine Handling Equipment; Gensets and Vehicles

Taking care of CCTV Systems, Access Control system and Fire Alarm System; tracking the consumables of facility services and maintaining records with minimum stock level

Developing daily cleaning & inspection check lists for LT Panels, UPS, HVAC System, Fire Pump System, Plumbing System, Rest Room, Meeting Room and so on

Maintaining the records of PM/breakdown schedule, service reports, history cards a well as inspection stickers by vendors and in-house team

Creating consumables of electro-mechanical materials, housekeeping materials and stationeries; collecting the quotation and preparing the cost comparison for FM and client approvals

Attending and monitoring the complaints/requisition/job card by facility team to management

SCADA Operations

Performing failure investigation analysis to identify gaps & take corrective measures so as to reduce equipment downtime & maximize plant availability

Proactively identifying areas of obstruction / breakdowns and taking steps to rectify the equipment through application of troubleshooting tools

Planning and effectuating preventive maintenance schedules of various machinery and instruments to increase machine up time / equipment reliability; also executing cost saving techniques/ measures and modifications to achieve substantial reduction in expenditures and work within the budget

Handling operations of HV/LV, Equipment, Generators, Transformers, Elevators, Escalators, Energy Meters and Other Plant Equipment as per design in auto, semi auto, manual from SCADA and local operations

Undertaking root cause analysis of problems and developing effective counter measures initiating improvement ideas generation & implementation

Installing Packages, Duct Able Splits, Cassettes and Tower A/c; operating air-cooled chillers, package units, duct able splits and cassette units

Laying the grills, making thermal and acoustic insulation throughout the duct

Held accountable for checking:

oChiller Performance and running parameters

oETS and provided Chilled Water Flow and Temperatures

oChemical Dosing & Parameters

Overseeing all chillers operations through a centralized SCADA Control Room - large capacity of 7000TR (YORK Make water Cooled Centrifugal Chillers Opt iView Control System / Model: YKKXKSK15DBGS)

Conducting inspection for chemical dosing pump & dosing tanks; chemical dosing as per requirement and preparing chemical dosing inventory functions

Involved in de-scaling work of Condenser and Evaporator Shell; taking care of PPM to the DDC panel as per the schedule

SCHOLASTICS PORTFOLIO

ITI - Mechanical Refrigeration & Air-Conditioning in year

NCVT University, Delhi

PERSONAL SNIPPETS

Date of Birth: 24th June, 1985

Address: 6-62, Godavarru, (Post), Kankaipadu (Mandal), Krishna (District), Andhra Pradesh, India 521151

Nationality: Indian

No. of Dependents: 2

Visa Details: Employment visa

Driving License Details: NA

Passport Status: G9909794 (Valid Up to 21st July, 2018)

Languages Known: English, Hindi & Telugu



Contact this candidate