PALANIAPPAN SEENIAPPAN

L-*** Periyar Nagar,

Surampatti Nall Road,

Erode - 638 009.

E mail - ac46of@r.postjobfree.com

EDUCATIONAL QUALIFICATION

Graduate : Bachelor of Science (Bio - Chemistry)

Year : 1986 - 1989

University : Bharathidasan University

PERSONAL DETAILS

Name : Palaniappan. S

Father's Name : Seeniappan P

Date of Birth : 01.03.1969

Sex : Male

Marital status : Married

Nationality : Indian

EXPERIENCE DETAILS

Total Experience : 23 Years

Overseas Experience : 15 Years

India Experience : 8 Years

WORK EXPERIENCE FOR OVERSEAS

Organization : Galfar Engineering & Contracting Company S.A.O.G

Designation : Chemist. Cum Water Treatment Plant In-charge

Duration : Nov 27 - 2008 to Nov 2016

Organization : M/S Oman National Engineering & Co (S.A.O.G)

Designation : Water Treatment Plant In-charge cum Chemist

Duration : April 2007 to Oct 20th 2008

Organization : M/S Oman Water Treatment Co. (SAOC)

Designation : Senior water Treatment Plant Operator

Duration : May 19th 2002 to April 15th 2005

Organization : M/s Zahran Maintenance & Operation Co. Ltd.

Designation : Water Treatment Plant Supervisor

Duration : Feb 8th 1997 to July 15th 1999

INDIA EXPERIENCE

Organization : Titanium Equipment & Anode Manufacturing Ltd.

Designation : Production Supervisor

Duration : Nov 1st 1993 to Sep 30th 1994

Organization : NEPC Ltd.,

Designation : Production Supervisor

Duration : Oct 5th 1994 to May 25th 1995

Organization : Saphire Aquamin Pvt Ltd, Bangalore.,

Designation : Plant In charge

Duration : Nov 5th 1995 to Dec 1st 1997

Organization : Vijaya Shanthi Builders Ltd.,

Designation : Production Supervisor

Duration : Dec 12th 1999 to Jan 22nd 2001

DUTIES AND RESPONSIBILITIES

1.Reverse Osmosis Plant

Capacity : - 7200 x 3 Cu.M/Day

Media Filters Backwash and Rinsing Routine.

Familiar in Operation of Water Treatment Plant SCADA system.

Cartridge Filter Chocked. Replaced Micron Filters Element.

Dosing Chemicals Preparation Depend upon the time. C12-SMBS-ANTISCALANT-OR-SULFURIC ACID.

PH Maintenance Lime Added.

Membrane Element Flow Less Alkaline Cleaning (EDTA) and High Conductivity Citric Acid Cleaning.

Pre- Chlorination Check the Point.

Feed Pump. And High Pressure Pump Oil Level and Running Hrs. Oil service done.

2.De - Mineralized Plant (D.M)

Media filters Backwash and Rinsing the Routine.

Pre- chlorination Checking.

Resin Element Regeneration Caution Element (Hcl) Anion Element (NaOH).

Monitoring Physical Test Checking Routine.

3.Electro Dialysis Plant (E.D)

Media Filters Backwash and Rinsing the Routine.

Pre-Chlorination Checking Routine.

Element for Cathode and Anode Charged the (Hcl)

Monitor and Physical Test Checking the Routine.

4. Softner Plant

Media filter Back Wash and Rinsing.

Pre - Chlorination Check the Point.

Physical and Chemical Analysis Doing.

Micron Filter Replaced.

Bottle Filling Machine Operation.

Water Analysis Doing.

EFFLUENT TREATMENT PLANT

A. Influent water maintain the PH.

B. Ferrous added the coagulant purpose.

C. Ultra filtration after Pressure media filtration.

D. Water Treatment Ist stage after IInd stage than IIIrd stage.

E. When the Delta pressure increase that time chemical cleaning.

F. Evaporator the reject water.

SEWARAGE TREATMENT PLANT

CAPACITY 1400 cu.m/day

a) Equalization tank inflow maintain than Aeration tank maintain the Dissolved oxygen.

b) Check the MLSS the Aeration Tank.

c) Aeration tank sludge volume increase that time transfer to sludge holding tank.

d) Chlorine contact tank maintain the Cl2.

e) DMF Back wash and Rinsing Routine 12hrs once.

f) Treated water maintain the Cl2 0.5 ppm.

LABORATORY WORK

Total HARDNESS, Calcium. HARDNESS, Magnesium HARDNESS, Total ALKALINITY, IRON & COPPER CHLORIDE, SULPHATE, FLUORIDE, NITRATE, PHOSPHATE and Dissolved Oxygen., AMMONIA BACTERIA TEST ALSO.

PHYSICAL ANALYSIS

TDS meter handling. Spectro Photo meter Model DR 2000 and DR 2800 and DR 5000. PH meter Handling & calibration.

SAFETY PROCEDURE

1. HSE induction 2. Life saving Rules 3. HEMP training course.

4. H2S Training course.

PASSPORT DETAILS

Passport No : M5715306

Date of Issue : 10.03.2015

Date of Expiry : 09.03.2025

Place of Issue : Muscat (Oman)

LANGUAGE CAPABILITY SPEAK READ WRITE

English Yes Yes Yes

Tamil Yes Yes Yes

Hindi Yes No No

Malayalam Yes No No

Kannadam Yes No No

Arabic Yes No No

DECLARATION

I here by declare that the information furnished above is true to the best of Knowledge.

Place: Erode

Date: Yours Sincerely,

[S. PALANIAPPAN]