Post Job Free

Resume

Sign in

Electrical Project

Location:
Thane, MH, India
Posted:
April 06, 2018

Contact this candidate

Resume:

Mansoor Ali .M. Semna

***/* ****** ****,

Gunpowder Road,

Mazagon,

Mumbai-400010. INDIA

Mobile No. India Mumbai: 0091-750-***-****, 0091- 986-***-****,

Application for the QC Electrical & Instrument Inspector ( Compex Certified ).

Respected Sir,

I undersigned Mansoor Ali M. Semna wish to apply for the above-mentioned post.

Having relevant construction experience of 15+ Years in Inspection ( Hazardous areas & safe Zones, Ex-certified Equipment’s / precommissioning in Electrical and Instrumentation field Related with Oil and Gas Industries(offshore – onshore Plat forms,Floating platforms, Well head Platforms, Rigs), Refineries, LNG project, Cross country pipeline, Medicine pharmaceutical plants,high rise buildings, Towers, American Consulate Building, 5/7 Star hotels ( Grand Hayat, Oberoi ), Villas, Bungalows and Fertilizer Plants. Worked with EPC and MNC World known Organization in India and Middle East, Mazagon dock ltd(A govt. of India Ltd), ONGC, National Electric Engineering C0.( for offshore rigs and platforms ) Broadway Electrical & Maintenance Consultants, Courtaulds Packaging, Sigma Pharmaceutical Plants, Al- Yusr Townsend & Bottom Co(Saudi Arabia),Consolidated Contracting Co.(C.C.C llc), AMEC (Azerbaijan-OIL PLATFORM, Baku topside project ), BOTAS (TURKEY ), OGEC-SHELL in West Africa in Gabon for Oil Gathering Station,(SAIPEM) Snamprogetti for 3rd NGL Train project, Technip – Italy Olefins’ 2 Ethylene project as QC Electrical & Instrument inspector., Fuel gas supply to QNCC-4 AND GCC -1 plant for QATAR PETROLEUM-(worked as TPI QC Inspector for Electrical & Instrument through Vellosi certification), Maersk Oil Qatar - Drilling oil platform,Single Buoy Moorings (for DELBA-II Floating Drilling Platform in U.A.E ), Sirate Oil Company (For Cross-country pipe line and pumping station in LIBYA), GASCO (U.A.E – For 250Km 52’’,62’’ H2S gas pipe line),Shell Iraq – in Majnoon oil field, Eni – Italy in Iraq-Basra- Zubair oil field for Pipe line project and DG stations,

I am furnishing My Resume in respect of Education and Technical Qualification, Working Experience and personal Details for your ready reference. If given Opportunity, I will Discharge my Duties sincerely & by hard work to the Satisfaction of my Superiors. And Serve my Best to your esteemed organisation

Awaiting for your prompt favourable Reply.

Regards,

Mansoor Ali . M . Semna.

Post Applied For : Q.C Electrical & Instrument Inspector Compex Certified

Name : Mansoor Ali .M . Semna

Address: 284/B Mistry Bldg, Gunpowder Road,

Mazagon, Mumbai-400010. – INDIA

Mobile no : 0091-986-***-****, 0091-750-***-****

E-mail : ac41xr@r.postjobfree.com ; Skype id: mansoor.semna

Date Of Birth: 21/12/1970 Health: Sound ; Marital Status: Married

New passport no : Z2032769 ; Old Passport No. : F 6351425

Place Of Issue : Dubai

Date of issue: 31/1/2010 Date Of Expiry : 31/1/2020

Education Qualification:

Diploma in Electrical Engineering.

Diploma in computer hardware.

Computer Skills:

Conversant with windows operating systems,internet, Ms 0ffice 2000,Auto cad,

COURSES / Training:

COMPEX ( EX-01, EX-02, EX-03,EX-04 ) FROM ATEC CERTIFICATION U.K (+44(0)800*******)

Certificate No.: 57153 ( Validity From 30th Sept 2016 – 30th Sept 2021 )

EX PROTECTION - ATEX COURSE FOR E & I INSPECTOR ( HAZARDOUS AREAS )

FROM INDUSTRIAL SUPPORT SERVICES – BRITISH PETROLEUM (AZERBAIJAN- BAKU )

ELECTRICAL & INSTRUMENTATION TRANING FOR INSPECTION OF CABLE GLAND “HAWKE“ FROM HAWKE GLAND COMPANY.

PERMIT TO WORK TRAINING (PTW) FROM BRITISH PETROLEUM

HSE HEAT STRESS, DEFENSIVE DRIVING, H2SO4 TRAINING, ETC FROM SHELL IRAQ- MAJNOON OIL FIELD.

PERFORMING AUTHORITY FOR ALL E & I WORKS FOR CONCERNED LOCATIONS.

License:

Holding Electrical Supervisor License issued by Govt. of Maharashtra (India - MUMBAI).

Career Objective:

To secure a position where I get an opportunity to utilize my talents/skills in a company where there is ample scope and growth for organizational as well as individual development.

To be conversant with the Project HS&E Plan. Proactively participate in achieving the highest possible International standard of HSE implementation. Familiarization with the job specification and review all documentation associated with Electrical & Instrument installation including, NEC, NFPA,B.S Standard’s .Inspection & Test Plans (ITP), Procedures, Method Statements, Vendor Documentation and Maintenance and Operations Manuals .Instrumentation including Inspection & Test Plans (ITP), Procedures, Method Statements, Vendor Documentation and Maintenance and to survey the work of Contractor is done as per standards.

LIST OF COMPANIES WORKED WITH

1) Schlumberger

CLIENT : K.O.C (Kuwait Oil Company)

DURATION: Oct 2017 till Jan 2018 - Fast track project

Designation: Q.C Electrical & Instrument inspector ( Compex Certified)

Project Title: JPF (Jurassic production facility a fast track project) at Sabriya.

2) Aker Solutions (BRUNEI )

CLIENT : SHELL BRUNEI

DURATION: May 2017 till Sept 2017 (OFFSHORE SHUT DOWN E&I works)

Designation: Q.C Electrical & Instrument inspector (Compex Certified)

Project Title: Shut down works for Ampa, Farley offshore Oil Platforms Fields

3) Chiyoda Japan ( IRAQ – BASRA – Rumaila Oil Field, LNG Rehabilitation Works )

CLIENT : Basra Gas Company (BGC)

DURATION: May 2014 till 25th July 2016

Designation: Q.C Electrical & Instrument inspector

Project Title: North Rumaila NGL Rehabilitation Work.

MY JOB RESPONSIBILITIES:

Job responsibilities for E & I works to review project docs. Specifications. ITP’s, DGS, Detail Inspection of contractors work for over all E & I Ex - Complied Equipment’s like motors, J.box, Lighting, and relevant instruments Hazardous ( Zone 0,1,2 ) and safe areas works, like cable laying, Electrical cable laying, J. Boxes,Lighting fixtures, flood lights, earthing, cable trays, Inspection for the installation and testing of Power Distribution Board, motor’s High and Medium voltage Switch gears ( ducter, IR, Hi-pot testing of its bus bar, Circuit Breaker (rack in- rack out, ducter, hi-pot testing). Inspection for installation and Testing of PA/GA System, CCTV System, installation of Junction Box, Cable laying for Power and Control cable, Fibre Optical Cables, Glanding & termination, FO Cable laying testing ( OTDR Test ), Instrument calibration and installation ( PT, PSV, MOV, FT, Gas Detectors, Pressure Gauge’s, Scada Etc.) instrument cables, instrument earthing ( Instrument and Clean earth ) etc., Participate in Punch list walk downs of completed electrical, Instrumentation and telecommunication systems and follow through to ensure punch items are closed and signed off. ETC

4) Eni - Italy (IRAQ – BASRA- ZUBAIR OIL FIELD)

CLIENT : ZFOD – IRAQ-BASRA ZUBAIR OIL FIELD (Pipe line project)

DURATION: APRIL 2013 – MARCH 2014.

Designation: Q.C Electrical and Instrument inspector

Project Title: PIPE LINE PROJECT

My job role was to monitor & Inspect the Electrical, Instrumentation( EX- certified equipment’s In hazardous and safe zone, Telecom, & Cathodic protection FO CABLING its testing, Closing of RFI, raising punch list, NCR, etc. of the contractor.

Electrical Works : Job involves inspection in Hazardous and non-Hazardous area’s for M.V, L.v cable laying testing and termination, trench inspection, inspection for Shelter substations, Earthing ( I.s, non I.S etc. ),motor installation and its testing, Ex- Junction boxes and its certification,Ex motors, Ex- fixtures etc. Grid earthing, raising punch list, Ncr and give correct remedy to closing ncr Etc. and relevant works.

Instrument Works : Job involves in inspection of Instrument cable laying and testing for I.S and Non I.S cables and testing,termination, witness of instrument calibration and its installation along with cabling and termination for PT, FT, PI, MOV, Shutdown valve, etc., Inspection of Instrument J.Box for certification and installation, Loop checks, impulse, airline tube tests,Etc. and relevant works.

Telecom: Inspection of Fibre optic cable laying and testing like OTDR, splicing of joints, and termination ETC. And relevant works.

Cathodic protection : Inspection of Pin brazing and it testing, installation of Test post,Equipotential test point ( ETP ), CP anode bed,Shunt insulating joint, PJB, NJB, and CP transformer .etc. and Relevant works.

5) SHELL (IRAQ – BASRA- MAJNOON OIL FIELD)

DURATION: JAN 2013 – MARCH 2013.

CLIENT : SOC – IRAQ-BASRA MAJNOON OIL FIELD (Pipeline / DEGASSING PROJECT )

Designation: Q.C Electrical and Instrument inspector

Project : Degassing Stations.

Job responsibilities to review project docs. Specifications. ITP’s, DGS, Monitor inspection of contractors work for over all E & I and Cathodic protection for EX Certified in Hazardous ( Zone 0,1,2 ) and safe areas works like cable laying, pin brazing, cald-weld on pipes, bond box for C.P, Test post for C.P, Xmer installation, RTU, Electrical cable laying, J.Boxs,Lighting fixtures, flood lights, earthing, cable trays, Inspection for the installation and testing of Power Distribution Board, High and Medium voltage Switch gears (ducter, IR, Hi-pot testing of its bus bar, Circuit Breaker (rack in- rack out, ducter, hi-pot testing). Inspection for installation and Testing of PA/GA System, CCTV System, installation of Junction Box, Cable laying for Power and Control cable, Fiber Optical Cables, Glanding & termination,Fo Cable laying testing ( OTDR Test ),Inspection of Instrument calibration and installation ( PT, PSV, MOV, FT, Gas Detectors, Pressure Gauge’s,TIC, PIC, XSDV, MOV Scada Etc.) instrument cables, instrument earthing,etc, Participate in Punch list walk downs of completed electrical, Instrumentation and telecommunication systems and follow through to ensure punch items are closed and signed off, raising opening and closing of NCR,ETC & relevant works.

6) SIRATE OIL COMPANY - LIBYA (LYBIAN GOVT COMPANY)

DURATION: MAY 2010 – February 2011.

Designation: Q.C Electrical and Instrument inspector

Project Title: LPG PIPE LINE PROJECT

CLIENT : SIRATE OIL COMPANY

Job responsibilities to review project docs. Specifications. ITP’s, DGS, Monitor inspection of contractors work for over all E & I and Cathodic protection for EX Hazardous ( Zone 0,1,2 ) and safe areas works like material, cable laying, pin brazing, cald weld on pipes, bond box for C.P, Test post for C.P, Xmer installation, RTU, Electrical cable laying, J.Boxs,Lighting fixtures, flood lights, earthing, cable trays, Inspection for the installation and testing of Power Distribution Board, High and Medium voltage Switch gears (ducter, IR, Hi-pot testing of its bus bar, Circuit Breaker (rack in- rack out, ducter, hi-pot testing). Inspection for installation and Testing of PA/GA System, CCTV System, installation of Junction Box, Cable laying for Power and Control cable, Fibre Optical Cables, Glanding & termination,Fo Cable laying testing ( OTDR Test ),Inspection of Instrument calibration and installation ( PT, PSV, MOV, FT, Gas Detectors, Pressure Gauge’s,TIC, PIC, XSDV, MOV Scada Etc.) instrument cables, instrument earthing,etc, Participate in Punch list walk downs of completed electrical, Instrumentation and telecommunication systems and follow through to ensure punch items are closed and signed off, raising opening and closing of NCR,ETC & relevant works.

7) Single Buoy Moorings - ABU DABHI

DURATION: OCT 2009 - April 2010.

Designation: Q.C Electrical and Instrument inspector

Project Title: DELBA III TDS 2500 PROJECT (DRILLING RIG)

Client : DELBA

My job involves Periodic Inspection of equipment and plant to be installed for topsides operation.

Inspection on platform in Hazardous (zone-0, 1, 2) & Safe areas included detailed inspection.

Inspection of installation of Cathodic protection anode and cathode electrodes and its cabling and testing, installed for topside project vessels.

Certified equipment on the platform on all systems i.e. Fire and Gas, Instruments, Telecom, landing Termination for I.S (insintrically safe circuits & Non I.S), tray, ladder rack its supports installation and Small power and all the drive systems Instrument termination Cabinets.

Telemetry cabinets, SCADA system installation its cabling, DCS cabinet installation its cabling, L.V & H.V switch gears like PCC, MCC, EDB, LDB etc. / Turbine generators of “ROLLSROYCE”, 33/11KV Transformers, Glycol regeneration package, water and gas injection compressors, Instruments installation & its cabling, Bacon light,navigation lighting, termination like transmitters, Nucleonic level transmitter, control valves, pressure Transmitters, solenoid valves etc. Raising punch lists for all faults found which are not as per standards specs of the project and then carrying out the appropriate remedial works. Worked out jobs as per inspection test methods. Read and refer Hazardous area classification, Instrumentation location plan P&ID drawing, hook up drawing. Involved in Instrument testing and report generation.

Monitor the subcontractor during testing activities to ensure compliance with the agreed test procedure, Reporting unsafe practices, and procedures to Qc Manager.

8) Maersk OIL QATAR: HAJIRA SURAT

DURATION: FEB 2009 - AUG 2009.

Designation: Q.C Electrical and Instrument inspector

Project Title: TOP SIDE PROJECT FOR HA & IA OIL PLATFORMS

Duties Involved:

Review and approval of Contractor submitted project quality procedures (PQP) and Inspection Test plans (ITP).

Issue of NCR (Non Conformance Report) and verifying the corrective actions in conformance with client standards and specification prior to clearing the NCR or site Instructions.

Perform Site Acceptance Test (S.A.T), onshore installations supervisions, Inspection, conducting walk through by individual systems and generating Punch Lists as per Project Specifications.

Establishing the Quality control procedures among various contractors and conducting the scheduled audits to verify the requirements.

Involved in Installation, Onshore testing and commissioning of 33.3, 11 Kv switchgear and 3.3 Kv switchgear, Oil filled and Dry type transformer, Lift gas heater panel, NER Panels, LV bus ducts, UPS distribution panel, Lighting panels and DB’s, UPS control panel (Gutor), Battery bank, Sand cleaning package, hypo chlorination package, Coarse filters, well head control panel and associated system, HVAC system, Nitrogen generator system, Instrument Air Compressor and dryer and chemical injection skids etc.

Functional test of F&G detectors, Fire dampers, shut off damper and Deluge valves, Testing and charge up of Normal and Emergency Lighting system, PA/GA speaker system, Telecommunication system, Navigational aid system, Bird desperation system, Aviation warning system and F&G system.

Installation of HV and MV cables, Glanding and termination, Cable jointing and Hi power testing.

Testing involved for CT, PT, CBCT, MCCB, Thermal over load relays, Earth leakage relays, Breaker test, schematic test, Protection relays, bus bar torque test, ductor test and high voltage test. Etc.

Installation and testing of Fusible loop system, Deluge water system, CCTV system etc.

Installation and pre commissioning of field motors, pumps and Motor Operated valves etc.

Inspection and verification of receipt of Materials and equipment’s in Yard, cross checking the records which are prepared by main contractor.

FAT (factory Acceptance Test) For Rosemount RS3 DCS system in factory. Siemens SCADA system etc.

9) Vellosi Certification Qatar:

DURATION: OCTOBER 2008 - 30th JANUARY 2009.

Designation: (TPI) Q.C Electrical and Instrument inspector.

Project Title: PUMP STATION (UMM BAB – DUKHAN)

Client : QATAR PETROLEUM

10) Technip -- ITALY

DURATION: March 2008 – 30th September 2008

Designation: Q.C Electrical Inspector

Project Title: OLEFINS II ETHYLENE PLANT PROJECT

Client : EQUATE (KUWAIT)

11) SAIPEM - (Snamprogetti SPA- Italy)

DURATION : June 2007 – February 2008

Designation : Q.C Electrical & Instrument Inspector

Project Title : 3rd NGL train Project

Client : GASCO

Check for the Quality of the Material in conformance with the specification requirements and BOM. (Material Receiving Inspection- Instruments, Cables, SS Tubes, Junction Boxes, Marshalling Panels, System Cabinets-DCS, ESD, F&G, MOV, XSDV, FIC, TIC, FR ETC.).

SAT (Site Acceptance Test) of various systems (Rose mount, Bailey system & Honeywell TDC 3000)

Check for the correct Installation of Instruments, Cables, Tubing, JBs, Panels, earthing, cable tray, MCT Engineering and Operator workstations as per the approved design drawings and WPP (work plan procedure).

Preparation & Clearing of Punch list with client representative.

Inspection for Plant earthing systems, Lighting works, cathodic protection systems etc.

Inspection for Switchgears, Motors, Transformers, Relay panels etc.

Review of Instrument Location Drawings, P&ID, PFD (Process Flow Diagram), Cause & Effect, Instrument Loop Diagram, & Hook up Drawings.

Witness instrument calibration on field and lab, leak test,etc

Maintaining the records as per standard QA Record procedure.

Telecom OSP and ISP duct bank inspections. FOC cable laying and testing, Inspection for conduit installation in buildings, Telecom instruments installation verifications etc.

Periodic Inspection of certified equipment’s to be installed as per required, zones.

Periodic inspection of installation routes and cable support systems prior to cable run.

Periodic inspection of installed tubing, hosing, cabling, glanding, termination

Periodic inspection of cabinet / station / instrument / connection and termination, glanding,

Periodic inspection of Earthings like IS earth, clean earth, Dirty earth, earth boss and earthing bar.

Checking of installation practices and quality of installation, alignment, level and orientation

Pre-run checking and punch-listing of equipment, system and component shortfalls

Monitor the subcontractor during testing activities to ensure compliance with the agreed

Testing procedures.

Witness meggering of HV, MV, LV cables Hi Pot test, SAT, insulation resist test, pre comm. of MCC, PCC, Xmers etc.

Participation during Internal Quality Audits, Co-ordinate with Pre-commissioning and commissioning activities including Loop test of all the DCS, ESD and F&G Loops.

10) OGEC – SHELL WEST AFRICA –GABON (Shutdown)

DURATION : March 2006 – Nov 2006

Designation : Q.C Electrical & Instrument Inspector

Project Title : GATHERING SATION

CLIENT : SHELL (GABON)

11) BOTAS ( A govt undertaking company TURKEY )

Duration : JUNE. 2005 TO 31st Feb 2006

Designation : Q.C Electrical & Instrument Inspector

Project Title : Cross country pipeline (Pump station,PT-04)

CLIENT : British Petroleum. (BTC)

12) AMEC (ATA) (Location: Azerbaijan, Baku)

Duration : Sept. 2004 TO May 2005

Designation : Q.C Electrical Inspector

Project Title : CA & CWP Platform (Topside project)

CLIENT : British Petroleum

13) CONSOLITATED CONSTRUCTION CO. WLL ( SAUDI ARABIA )

Duration : FEB. 2003 TO JULY 2003 (BADGE NO – 81458)

Designation : Q.C Electrical Inspector

Project Title : QGP1 (QATIF GAS PROJECT)

CLIENT : ARAMCO

CONSULTANT: SNAMPROGETTI

14) BROADWAY ELECTRICAL & MAINTAINENCE CONSULTANT. ( Mumbai, India )

Designation : Electrical Engineer

Duration : 2000-2002 (2Years)

JOBS DONE ON CONRACT BASIS:

Hotel Grand Hayat- 7 star hotel (Mumbai, Andheri)

15) AL YUSR TOWNSEND & BOTTOM CO (AYTB) IN SAUDI ARABIA

Duration : 1999 TO 2000

Designation : Q.C Electrical Inspector & Instrument Inspector

Project Title : Cracking furnace

CLIENT : PETROKEMYA

CONSULTANT: TECHNIP

16) M/s. NATIONAL ELECTRIC ENGG. CO. : ( INDIA )

Duration : 1993 – 1999

Designation : Electrical Engineer / Site INSPECTOR.

CLIENTS : ONGC, DOLFHIN OFFSHORE, ENGINEERS INDIA LTD, MAZAGON DOCKS LTD, LARSON & TUBRO,SIGMA PHARMACETICALS, COURTAULDS PACKAGING, LIBERTY OIL MILLS, RESERVE BANK OF INDIA, PARLE BOTTLING’S, Villas, High rise bldgs, 5/7 star hotels etc ETC.

Company Profile: An Electrical Contracting Firm having “AA” class license. It undertakes

Turnkey projects like Industrial, Manufacturing of MCC’s, PCC’s, 33kv Main breaker Panels, Telemetry Panels, On-shore/Offshore works (Elect. & Inst.)Commercial and Multi-story buildings. It also undertakes Consultancy Services.

REFERENCE PERSONS

Avinash Lele senior instrument engineer – chiyoda corp, Japan – Iraq ac41xr@r.postjobfree.com ; ac41xr@r.postjobfree.com

Chiyoda Japan Iraq Rumaila : Murata Hiroshi Site Manager ac41xr@r.postjobfree.com

( Eni Italy _ IRAQ Basra- ZUBAIR ) Project Manager Augusto Correirer - ac41xr@r.postjobfree.com

( SHELL - IRAQ Basra – MAJNOON ) QA/QC MANAGER - david.walker @shell.com )

( Sirate Oil Company Libyan Govt Company )Senior Project Engineer John Ford - ac41xr@r.postjobfree.com

( Sirate Oil Company Libyan Govt Company ) Robin Glen Senior Electrical and Instrumentation Engineer ac41xr@r.postjobfree.com .

Mr. Derek Hall, QA/QC Manager, Technip Italy S.P.A, Olefin II Kuwait Ethylene Project

E-Mail: ac41xr@r.postjobfree.com, Mobile No. +965-*******.

Mr. Martin embleton [ac41xr@r.postjobfree.com] MAERSK OIL QATAR SR QC ENGINEER.

Mr. Giuseppe Figlioli, Administration Manager, Technip Italy S.P.A, Olefin II Kuwait Ethylene Project, E-Mail: ac41xr@r.postjobfree.com, Mobile No. +965-*******

IN GENERAL ELECTRICAL AND INSTRUEMENT JOB RESPONSIBILITIES PERFORMED :

DETAILS OF WORK EXCECUTED IN ELECTRICAL FIELD OF CONSTRUCTION IN OIL AND GAS, PETROCHEMICAL PLANTS, GATHERING STATIONS, CROSS COUNTRY PIPE LINES, CRACKING FURNANCE AND OFFSHORE / ONSHORE TOP SIDE PROJECTS AND PHARMACEUTICAL PLANTS, HOTELS, VILLAS, BUNGLOWS.

Monitoring contractor’s installation work at site as per standards, ITPS, project specs. Inspection in Hazardous (zone-0, 1, 2) & Safe areas included detailed inspection of all EEX Certified equipment. Inspection of certified equipment’s for plants project work involved .Review field quality control procedure, making punch list, reports for inspection work involved as per their procedure & specification for inspection of material’s, inspection of installation & testing of electrical ltg. fixtures, Navigation light (Air craft warning light ), flood ltg fixtures, Cut out Type fixtures, Concealed fixtures, Highway fixtures etc, motors, glanding, cable meggering, earthing,conduit installation check, wire pulling check, terminations,support installation check for fixture’s, conduits, panel, d.board, j. box installation inspection Wiring & erection of Lighting fixtures & Receptacles, Inspection of installation of Cathodic protection anode and cathode electrodes and its cabling and testing installed for vessels U/G & A/G pipe lines, vessels etc., heat tracing tape,Cable trays, J.Box, Cabling for panels, Analyzers, pumps and motors, Electrical Panels for Utilities, HVAC, Diesel Generator, Lighting and Receptacles, Lightning arrestors, i.s and non i.s earthing,Fire Alarm & Fire Suppression Sprinkler Systems as per Drawings and Specifications of the contract etc.

Periodic Inspection of certified equipments to be installed as per required, zones.

Periodic inspection of installation routes and cable support systems prior to cable run.

Periodic inspection of installed tubing, hosing, cabling, glanding, termination

Periodic inspection of cabinet / station / instrument / connection and termination, glanding,

Periodic inspection of Earthings like IS earth, Clean earth, Dirty earth, earth boss and earthing bar.

Checking of installation practices and quality of installation, alignment, level and orientation

Pre-run checking and punch-listing of equipment, system and component shortfalls

Monitor the subcontractor during testing activities to ensure compliance with the agreed

Testing procedures.

Witness meggering of HV, MV,LV cables Hi Pot test,SAT,insulation resist test, pre comm. of MCC, PCC, Xmers etc.

Witness of Substation equip installation & testing for 33kv, 132kv like PCC, Breaker panel, Capacitor panel, UPS panel etc, cable H.V cable jointing,etc

Witness meggering, no load test, winding test, vibration, bearing temp, and speed.

Circuit testing preparation and witness pre-commencement power / signal checks

Perform inspection of all equipment during equipment pre-commissioning / commissioning

Prepare and review test documentation, submit results to Certification Engineers

Making of punch list and showing corrective measures to the contractors.

Close out the changes made through NCR’s Site Instructions & Engineering queries appropriately.

Making punch list and giving corrective actions to be performed.

DETAILS OF WORK EXCECUTED IN ELECTRICAL FIELD FOR TOPSIDE PROJECT.

My job involves Periodic Inspection of equipment and plant to be installed for topsides operation.

Inspection on platform in Hazardous (zone-0, 1, 2) & Safe areas included detailed inspection.

Inspection of installation of cathodic protection anode and cathode electrodes and its cabling and testing, installed for topside project vessels.

Certified equipment on the platform on all systems i.e. Fire and Gas, Instruments, Telecom, landing Termination for I.S (insintrically safe circuits & Non I.S), tray, ladder rack its supports installation and Small power and all the drive systems Instrument termination Cabinets.

Telemetry cabinets, SCADA system installation its cabling, DCS cabinet installation its cabling, L.V & H.V switch gears like PCC, MCC, EDB, LDB etc. / Turbine generators of “ROLLSROYCE”, 33/11KV Transformers, Glycol regeneration package, water and gas injection compressors, Instruments installation & its cabling, Bacon light,navigation lighting, termination like transmitters, Nucleonic level transmitter, control valves, pressure Transmitters, solenoid valves etc. Raising punch lists for all faults found which are not as per standards specs of the project and then carrying out the appropriate remedial works. Worked out jobs as per inspection test methods. Read and refer Hazardous area classification, Instrumentation location plan P&ID drawing, hook up drawing. Involved in Instrument testing and report generation.

Monitor the subcontractor during testing activities to ensure compliance with the agreed test procedure, Reporting unsafe practices, and procedures to Qc Manager.

DETAILS OF WORK EXCECUTED IN INSTRUMENTATION FIELD OF CONSTRUCTION IN OIL AND GAS, PETROCHEMICAL PLANTS, GATHERING STATIONS, CROSS COUNTRY PIPE LINES, CRACKING FURNANCE AND TOP SIDE PROJECTS ( onshore / offshore ) HOTELS, VILLAS, BUNGLOWS..

My job includes monitoring contractors installation work at site as per standards, ITPS, project specs, Inspection in Hazardous(zone-0,1,2) & Safe areas included detailed inspection of all EEX Certified equipment Inspection of certified equipment’s for plants project work, Review field quality control procedure, making punch list, reports for inspection work involved as per their procedure & specification for inspection of material, instruments, inspection of installation & testing meggering testing of power, single cable ( Concealed type in conduits, underground, above ground,, I.S earthing witness laying of instrument cable under/above ground, its glanding, installation of cable tray, FJB, junction box, telemetry interface cabinets, witness calibration and installation of instrument liker shut down valves, Pressure safety valves, flow transmitters, recorders, fusible plugs, nucleonic meters, gauges, orifice plates,, ESD/FSD system.

Familiarization with the job specification and review all documentation associated with Instrumentation including Inspection & Test Plans (ITP), Procedures, Method Statements, Vendor Documentation and Maintenance and Operations Manuals relative to the topsides modules.

Periodic Inspection of equipment and plant to be installed for topsides operation and SAT..

Periodic inspection of installation routes and cable support systems prior to cable run.

Periodic inspection of installed tubing, hosing, cabling, glanding, termination

Periodic inspection of cabinet / station / instrument / connection and termination, glanding, earthing and neatness, penetration sealing and instrument / tubing / cable identification

Checking of installation practices and quality of installation, alignment, level and orientation

Pre-run checking and punch-listing of equipment, system and component shortfalls

Monitor the subcontractor during testing activities to ensure compliance with the agreed testing procedures.

Inspection of installation of Cathodic protection anode and cathode electrodes and its cabling and testing installed for vessels U/G & A/G pipe lines, vessels etc

Witness pressure / leak / integrity testing of instrumentation tubing prior to testing

Circuit testing preparation and witness pre-commencement power / signal checks

Perform inspection of all equipment during equipment pre-commissioning / commissioning

Prepare and review test documentation, submit results to Certification Engineers

Close out the management changes made through NCR’s Site Instructions & Engineering queries appropriately .



Contact this candidate