Post Job Free
Sign in

Electrical Engineer Project

Location:
Islamabad, Islamabad Capital Territory, Pakistan
Salary:
12000 QAR
Posted:
December 24, 2017

Contact this candidate

Resume:

ABID NADEEM ABDUL MAJEED

Cell# +923********* (PAK) +964********** (IRAQ)

Email: abid,********@*****.***, ****.*********@*****.***

E&I ENGINEER CONSTRUCTION, QA/QC & COMMISSIONING

PROFESSIONAL OBJECTIVE:

To get a career oriented job in a professional environment that offers utilization of my technical skills and provides learning opportunities to keep pace with advanced technologies.

EXPERIENCE SUMMARY

Having 20 Years’ professional experience in Supervision, Quality Control, Construction, Pre-Commissioning and Commissioning that exposed in

-Oil Field’s (ARAMCO, QP, SOC, JOE, LUKOIL)

-Gas Field’s (NGL Yanbu KSA, NGL-1&3 Mesaieed Qatar)

-Pipe Line’s (48”, 42”, 36”, 24” Pipelines Projects)

-Petrochemical Plant’s (Ammonia 1 & 2 Plant in QAFCO Mesaieed Qatar)

-Power Plant’s (Diesel Generators, Gas Turbines, Steam Turbines, Heat Recovery & Steam Generation (HRSG) Combine Recycle and Power Generation)

-Substation’s (380/110/13.8KV, 110/13.8KV, 33/3.3/0.415KV and 11/0.415KV)

-QC Inspection (ARAMCO, QP, QAFCO, JOE SOC, LUKOIL, BAZIAN)

EDUCATION:

B-Tech (Electrical, GPA 3.5) From Preston Institute of Management, Science and Technology Lahore, Pakistan 1997.

DETAIL OF WORK EXPERIENCE

Present:

1.Organization: BV (Bureau Veritas) (9-Aug 2017 – till date)

Function: THIRD PARTY INSPECTOR E&I

Project: Erbil International Hotel Erbil Iraq

Projects Handled: Modern Surveying Erbil Iraq

Main Client: Erbil International Hotel Erbil Iraq

Location: Erbil Iraq

Responsibilities:

Installation, surveillance, Inspections, and testing for following systems,

Inspection of installation and testing of Fire alarm system.

Inspection of installation and testing of Sprinkler system.

Inspection of installation and testing of earthing system.

Inspection of installation and testing of Lightning protection system.

Inspection of installation and testing of X-Ray machine and metal detector.

Inspection of installation and testing of Generator and LV Distribution panels.

2.Organization: BV (Bureau Veritas) (8-July 2017 – 23-July 2017)

Function: THIRD PARTY INSPECTOR E&I

Project: Bazian Oil Refinery Sulaimaniyah Iraq

Projects Handled: Modern Surveying Erbil Iraq

Main Client: Bazian Oil Refinery Sulaimaniyah Iraq

Location: Sulaimaniyah Iraq

Responsibilities:

Installation, surveillance, Inspections, and testing for following systems,

Inspection of installation of cable trays and cables laying and termination, DB’s, tank level transmitters and temperature transmitters.

Witnessed Site Acceptance Test (SAT) and calibration of tank Level transmitters, Temperature transmitters and verified all signals in DCS.

3.Organization: SGS –Supervise Gözetme Etüd Kontrol Serv. A.Ş. (March. 2016 – June 2017)

Function: THIRD PARTY INSPECTOR E&I

Project: 42” 106 KM PIPELINE PROJECT (CPF TO TTF)

Projects Handled: TECHNO ENGINEERING

Main Client: LUKOIL & SOC

Location: West Qurna-2 to Tuba Tank Form Basra Iraq

4.Organization: BV (Bureau Veritas) (Feb 2015 – Feb.. 2016)

Function: THIRD PARTY INSPECTOR E&I

Project: West Qurna Field, 2nd Phase Project (Mishrif Central Processing Facilities (CPF)

And EPC Well Pads & Oil Gathering System of West Qurna Field, 2nd Phase

Project (Early Oil Phase).

Projects Handled: SAMSUNG ENGINEERING

Main Client: LUKOIL & SOC

Location: West Qurna-2 Basra Iraq

Responsibilities:

Installation, surveillance, Inspections, and testing for following systems,

Reviewed the ITPs, Project specification, Drawings, Data sheets and Vendor manuals and identifying system/sub-system limits as per related standards.

•Review project contract documents and monitoring construction activities to ensure compliance.

Monitored and evaluated electrical tests such as ground-fault, ground resistance, insulation resistance, polarity, continuity, capacity, load and other electrical field tests as required.

Field check installation and location of electrical equipment, electrical duct, conduit, cable, panels and other components of the electrical system being installed.

Monitored all electrical installations to assure circuitry phasing, equipment, and grounding adhere to construction documents and applicable codes requirements.

Conducted Material Inspection as per approved material submittal

Verified equipment settings, alignment and testing requirements.

Ensured Contractors' compliance with contract specifications and approved shop drawings.

Provided general inspection on all Contractor and Sub-Contractor work to assure a safe and workman-like operation.

Monitored and report contractor progress and all activities

Reviewed and monitored variations to the work to mitigate time and cost impacts for any required changes

Liaised with the Senior Discipline Engineer and other Engineers and Managers to provide support and guidance as required

Monitored safety aspects when dealing with the installations

Maintained registers of all submittals and testing

Maintained full site records, including daily site diaries in an approved format, and formal daily progress photography.

Maintained full site records, including daily site diaries, contractor’s manpower and equipment daily resources in an approved format, and formal daily progress photography.

Materials receiving inspection in ware house/ store according to project specification such as F&G system PRV, PCV, ESD, Line block valves, Vender packages and all kind of transmitter, Switchgears, motors, transformers, panels, DTN (Data Transmission Network), TETRA Radio, Micro wave, LDS (Leak detection system), CCTV, Radar System, ACS (Access control system), (as per P. O. Packing list, test certificate, compliance certificate etc.).

Inspection the installation of cable trays, conduits, cables laying, cables Glanding & terminations, cable jointing, Lighting and small power distribution, Earthing and Lightning protection, 33KV Overhead Lines, Dis-connectors, Breakers, and 33KV, 415V Switchgears, 33/0.415KV 2.5 MVA transformers testing and pre-commissioning and commissioning.

Inspection the installation and calibration of all kinds of instrument according to check lists and Method statement as per project specification. Calibration of Electronic Instruments like Differential Pressure, Level, Temperature Flow Transmitter, Control Valves, Controllers, Routinely calibrated & configured smart series Instruments with HART Communicator.

Inspection and Witnessed Site Acceptance Test (SAT) for Process control equipment (SCADA/PLC, Panels, Instruments TT, PT, FT, PDT, TSV, DHE, DFI, DMC, DAF, DFB, etc.).

Supervised the installation, testing, pre-commissioning and commissioning of DTN (Data Transmission Network), TETRA Radio, Micro wave, LDS (Leak detection system), CCTV, Radar System, ACS (Access control system).

5.Organization: BV (Bureau Veritas) (March. 2014 to Jan.2015)

Function: PMC Field Representative E&I

Project: Crude Oil Export Facility Reconstruction Project (Onshore & Offshore Sea line) of

South Oil Company Al Faw, Basra-IRAQ

Projects Handled: Leighton Offshore Australia

Main Client: JOE (Japan Oil Engineering Company) & SOC

Location: Al Faw Basra Iraq

Responsibilities:

Installation, surveillance, Inspections, and testing for following systems,

Project Management Consultant E&I to Ensure the Implementation of Quality Management System according to requirements of ISO 9001:2008 at each phase of project. Elaborated and organized the Electrical & Instrumentation specifications, codes and standards for Crude Oil Export Facility Reconstruction Project (The Project aims to develop the offshore loading facilities to enable further export capability among main terminals of onshore Fao Oil Storage Terminal (FOT), offshore Al Basra Oil Terminal (BOT) and offshore Khor Al Amaya Terminal (KAAT) and Single Point Mooring (SPM-4). 33/11/0.4KV Substation (HV, LV Switchgears, Transformers, SCADA and PLC Panels, UPS and Battery Banks, Fire Alarm and Gas Detection System, Subsea Composite Cable (33KV+FOC) HV, LV, Control and Instrument Cables laying, Glanding, Meggering, Hi-Pot Tests and Termination, Earthing and Lightning Protection system, Indoor and Outdoor Road Lights, Cathodic Protection for 48” Pipelines, Valve Station-1 at Offshore AlBasrah Oil Terminal, Valve Station-2 at Khor Al Amaya Terminal Plate forms and SPM-4 (Single Point Mooring).

Administered assigned subcontracts to ensure contract remains up to date in areas such as drawings, specifications, cost and schedule.

6.Organization: Black Cat Engineering & Construction Doha, Qatar (Sep. 2013 – Feb.2014)

Function: QA/QC Inspector (E & I)/Supervisor - Approved from Qatar Petroleum

Project: EPIC for Installation of Continuous Emission Monitoring System on Selected

Combustion Sources in NGL-1&3 Mesaieed & Dukhan Gas Plants-Qatar.

GC-11114300

Projects Handled: Black Cat Engineering & Construction Doha, Qatar.

Main Client: Qatar Petroleum

Location: Mesaieed Qatar

7.Organization: Black Cat Engineering & Construction Doha, Qatar (Oct. 2012 – July 2013)

Function: QA/QC Inspector (E & I)/Supervisor - Approved from Qatar Petroleum

Project: EPIC for Ammonia Recovery & Flare System in Ammonia 1 & 2 Plant in QAFCO

Mesaieed Qatar. Contract No:11-1668

Projects Handled: Black Cat Engineering & Construction Doha, Qatar.

Main Client: QAFCO

Location: Mesaieed Qatar

8.Organization: Black Cat Engineering & Construction Doha, Qatar (Sep. 2011 – Sep. 2012)

Function: QA/QC Inspector (E & I) - Approved from Qatar Petroleum

Project: EPIC of Produced Water Treatment and Injection in Old Oil Wells at Dukhan Oil

Field Phase-II GC –10100600

Projects Handled: Black Cat Engineering & Construction Doha, Qatar.

Main Client: Qatar Petroleum

Location: Dukhan Qatar

9.Organization: Black Cat Engineering & Construction Doha, Qatar (July 2010 – August. 2011)

Function: QA/QC Inspector (E & I) - Approved from Qatar Petroleum

Project: EPIC of Sweet Fuel Gas Supply to Dukhan Consumers. Dukhan Qatar

GC – 09102200

Projects Handled: Black Cat Engineering & Construction Doha, Qatar.

Main Client: Qatar Petroleum

Location: Dukhan Qatar

Responsibilities:

Installation, surveillance, Inspections, and testing for following systems,

Maintained a daily presence on-site assisting the Contractor by coordinating works to ensure the Electrical Works are carried out in accordance with the project specifications and requirements. Inspect all the activities on site in accordance to the required standards and protocols related to the Electrical Works and assigned by the Electrical Engineer.

Followed the tasks assigned for inspection from the Electrical Engineer.

Attend inspections via Work Inspection Requests and provide accurate inspection comments.

Provided inspection comments and submit to Electrical Engineer for verification.

Assured inspections are carried out as per schedule and procedure.

Reported to Electrical Engineer any non-conformance observed during inspections.

Advice on any Electrical Work problems, issues and deficiencies identified to the Electrical Engineer in a timely manner.

Maintained Daily Works Records in an agreed format. Submit the Daily Work Records to Electrical Engineer on a Daily basis.

Assist Senior Structural and Structural Engineers in the preparation of the monthly Project STATUS Report.

Performed Snagging Procedure in accordance to Electrical Engineer instruction;

Provided to Electrical Engineer the STATUS of snagging and re-snagging of the Electrical Works as per site condition.

Provided status to Electrical Engineer regarding completion of outstanding Electrical Works by the Contractor when required.

Supervised all aspects of inspection disciplines and give work direction to all inspection and personnel in the assigned groups or in the remotely located units.

Ensured adequately trained and certified personnel are available to meet the workload. Assured that all WORK is completed according to all applicable codes and standards, and keep current of the latest developments in inspection standards, codes, practices, procedures, methods and inspection equipment.

Reviewed/evaluated CONTRACTOR’s quality assurance/quality control systems, as necessary, and ensure Inspection Records (hard copy and electronic databases) are compiled and maintained

Make frequent visits to construction sites to resolve inspection related problems, or appraise adequacy of inspection services provided.

Performed root cause analysis, assessments, and recommend short and/or long-term remedies provided technical support to Purchasing and Project Management in resolving problems concerning inspection methods and procedures for completing WORK within the scope and intent of applicable codes and standards.

Installation of 33KV, 3.3KV, 0.415KV Switchgears, 33/3.3KV and 3.3/0.415KV Transformers as per manufacturer instructions (MI), project specifications and method statements.

Witnessed Site Acceptance Test (SAT) for all Electrical equipments (33, 3.3, 0.415KV Switchgears, 33/3.3KV and 3.3/0.415 Transformers, UPS, SCS, MCC, Lighting and Small power DBs, testing of bus bar joint contact resistance and torque test, IR test, Hi Pot test for bus bar and incoming/outgoing cables, CT & PT tests, Circuit breaker test, Integrity of earthing Space heater functional check, Transformer protection scheme (Alarm/Trip) checked and verified with respect to upstream and downstream feeder, All protection relays are tested and protection setting parameters are initialized as per AFC document, Cable termination torque values are verified as recommended by the vendor, Phase sequence checked and verified prior to energization, Checked the overall arrangements and assembly of panel - Cable termination, Panel cleaning and panel cover box up, Motors Solo run and Performance tests) at KNDS, JMDS, FNDS, FMDS Dukhan area.

Distribution Boards, Control Panels, Variable Speed Drives, Soft Starter, Uninterruptible Power Supply Systems, Underground Utilities, Street Lighting, Cable Raceways, Lighting and Small Power, Earth Protection Systems, Lightning Protection Systems.

Fire Alarm & Gas detection System, Telecommunications Networks, SCADA System, Control Systems and Security Systems.

Installation and calibration of all kinds of instrument according to Datasheets, check lists, Specification & Method statements. Calibration of Electronic Instruments like Differential Pressure, Level, Temperature Flow Transmitter, Control Valves, Controllers, Routinely calibrated & configured smart series Instruments with HART Communicator.

Witnessed Site Acceptance Test (SAT) for Process control equipment (SCADA/PLC, Panels and Instruments).

Executed the specific inspections on all incoming E&I materials and equipments.

Issued NCRs on identification of nonconformities and Monitor the effectiveness of Corrective actions.

Inspection of installation, testing, pre-commissioning and commissioning of cathodic protection for pipelines.

10.Organization: Al Suwaidi Industrial Services Company Jubail KSA (Sep.2008 – June.2010)

Function: QA/QC Inspector E&I - Approved from Saudi ARAMCO SAP# 70008775

Project: EPIC of Fuel Loading Racks in Bulk Plant Yanbu Saudi Arabia

Projects Handled: Al Suwaidi Industrial Services Company Jubail KSA

Main Client: ARAMCO Saudi Arabia

Location: Yanbu Saudi Arabia

11.Organization: Al Suwaidi Industrial Services Company Jubail KSA (Oct. 2006 – August. 2008)

Function: E&I SUPERINTENDENT

Project: EPIC of Replaced All Fire & Gas Detection System in Yanbu Oil Refinery KSA.

Projects Handled: Al Suwaidi Industrial Services Company Jubail KSA

Main Client: ARAMCO Saudi Arabia

Location: Yanbu Saudi Arabia

12.Organization: Al Suwaidi Industrial Services Company Jubail KSA (August 2004 – Sep. 2006)

Function: E&I SUPERINTENDENT

Project: EPIC of Ethane Gas & Butane Liquid Feed Surge System in Natural Gas Liquid

Plant Yanbu Saudi Arabia

Projects Handled: Al Suwaidi Industrial Services Company Jubail KSA

Main Client: ARAMCO Saudi Arabia

Location: Yanbu Saudi Arabia

Responsibilities:

Installation, Inspections, surveillance and testing for following systems,

Installation of 33KV, 0.415KV Switchgears, 33/0.415KV 1.2MVA Transformers as per manufacturer instructions (MI), project specifications and method statements.

Power Transformers, 33/0.415KV 1.2MVA,Testing, Oil Sampling, Tan Delta Test, Winding Resistance Test, Bus Duct’s, Circuit Breaker SF6, Vacuum Circuit Breaker, Contact Resistance Test, Trip Timing Test Switchgear’s, VTs, CTs, Protection Relays, Protection CTs, Metering CTs, Testing, Saturation Test, Stability Test, Primary Injection & Secondary Injection Testing, Emergency Diesel Generators,, Power & Control system, HV, MV, LV Cables, IR Test, Hi Pot Test, Termination Torque Test as per Data Sheet, Low voltage switchgear, Motor Control Centres, Automatic Harmonic Filter, Power Factor Corrections.

Distribution Boards, Control Panels, Variable Speed Drives, Soft Starter, Uninterruptible Power Supply Systems, Underground Utilities, Street Lighting, Cable Raceways, Lighting and Small Power.

Fire Alarm System, Telecommunications Networks, Earth Protection Systems, Lightning Protection Systems, Control Systems and Security Systems.

DCS, ESD, SCADA, PLC, Fire & Gas: Sprinkler system, Fire Fighting, VESDA, Loop Check of all instrument, Functional checks for ESD & Control valves, Graphic verifications from LOC & MOC. P&ID & Instrument Hook up’s, Air Piping, Pressure, Flow and Temperature Elements, Impulse line tubing testing, Analyzers, PT100, RTD’s, RTU’s, Control Valves and Fiber Optics.

Installation and calibration of all kinds of instrument according to Datasheets, check lists, Specification & Method statements. Calibration of Electronic Instruments like Differential Pressure, Level, Temperature Flow Transmitter, Control Valves, Controllers, Routinely calibrated & configured smart series Instruments with HART Communicator.

Telecommunication, Public Address, Door Access, Data & Voice, CCTV and SMATV.

Partial stroke test and stroke test for valves (ESD, Control & On-Off).

Pressure and load testing of pneumatic, hydraulic and process tubing. ESDV’s, MOV’s, PCV’s, ROV’s and HIPPS system functional tests.

13.Organization: Al Fanar Construction Company, Riyadh, Saudi Arabia (July 2003 – July 2004)

Function: SENIOR SUPERVISOR ELECTRICAL

Project: EPIC of Construction of 110/13.8 KV Alnagha GIS Substation, Madina KSA

Projects Handled: Al Fanar Construction Company, Riyadh, Saudi Arabia

Main Client: SCECO Saudi Arabia

Location: Madina Munawara Saudi Arabia

14. Organization: Al Fanar Construction Company, Riyadh, Saudi Arabia (March 2002 – June 2003)

Function: SENIOR SUPERVISOR ELECTRICAL

Project: EPIC of Construction of 110/13.8 KV Mushrefa GIS Substation Jeddah KSA

Projects Handled: Al Fanar Construction Company, Riyadh, Saudi Arabia

Main Client: SCECO Saudi Arabia

Location: Jeddah Saudi Arabia

15. Organization: Al Fanar Construction Company, Riyadh, Saudi Arabia (Jan-2001 – Feb.2002)

Function: SENIOR SUPERVISOR ELECTRICAL

Project: EPIC of Construction of 110/13.8 KV Mina II GIS Substation Makkah KSA

Projects Handled: Al Fanar Construction Company, Riyadh, Saudi Arabia

Main Client: SCECO Saudi Arabia

Location: Makkah Saudi Arabia

16. Organization: Al Fanar Construction Company, Riyadh, Saudi Arabia (May 1999 – Dec.2000)

Function: SENIOR SUPERVISOR ELECTRICAL

Project: Construction of 380/110/13.8 KV Wadi Jaleel outdoor Substation Makkah KSA

Projects Handled: Al Fanar Construction Company, Riyadh, Saudi Arabia

Main Client: SCECO Saudi Arabia

Location: Makkah Saudi Arabia

Responsibilities:

Supervision of Installation and testing for following systems,

Installation, Erection of 380/110/13.8 KV outdoor Substation, 110/13.8 KV GIS indoor substation (ABB, ALSTOM, AEG, HITACHI) SF6 Circuit breaker, Dis-connector Switches, Earth Switches, CT, VT, Lightning & Surge arrestors, control, relay, SCADA & PLC panels. UPS, fire alarm System & sprinkler system, HVAC & control system, indoor, outdoor lighting, electrical control of live line insulators washing system for outdoor substation.

Witnessed the testing of CT, VT, (ratio, polarity, insulation, magnetization, resistance) CBs, (timing, Contact resistance, dew point, and pole discrepancy). Protective relays tested (O/C & E/F, REF, DIFF, AUX, RELAYS) and bus bar tests.

Inspection of Transmission & Distribution cables laid and jointing (110 KV & 13.8 KV Cables).

17. Organization: Westinghouse Electric Corporation (USA), Pakistan (Oct.1997 – April.1999)

Function: Assistant Electrical Engineer

Project: Construction of Fauji Kabirwala Power Plant 157 MW Combine Cycle Power

Plant Khaniwal, Pakistan.

Projects Handled: Westinghouse Electric Corporation (USA), Pakistan

Main Client: Fauji Foundation

Location: Kabirwala Khaniwal Punjab Pakistan

Responsibilities:

Supervision of Installation and testing for following systems,

Supervised the installation of Steam & Gas Turbines, generators, boilers, main Centreline Equipments and associated electrical auxiliary systems, Protection equipments, Control Relays, instrument panels, pneumatic system, FM200 fire protection system, cables termination of control and power Cables in panels. Motors & transformers, UPS & DC distribution System.

Tested and commissioned of Steam & Gas Turbines, generators, boiler equipments, main Centreline Equipments and associated electrical auxiliary systems, Protection equipments, Control Relays, instrument panels, pneumatic system, FM200 fire protection system, UPS & DC distribution System, cables Continuity, Meggering & DC Hi- pot test of HV, MV cables.

JOB RESPOSIBILITIES:

The experience hatches all the advance systems such as,

ELECTRICAL POWER & CONTROL SYSTEM:

Power Transformers: 380/110KV, 110/13.8KV, 33/11.5 KV 33/3.3KV & 11/0.415KV, 500MVA, 40MVA, 2.5MVA, 1.2MVA and 800 KVA Transformer Terns Ratio, (TTR) Testing, Oil Sampling, Tan Delta Test, PI Index & Winding Resistance Test, Magnetic balance test, protection device functional test such as winding & oil temperature alarm, trip, main tank buchholz alarm, trip, PRD trip, Oil breakdown value test.

Circuit Breakers MV & LV: SF 6, Vacuum Circuit Breaker & Air CBs Testing, Contact Resistance Test, Trip Timing Test & IR Testing of ACB, over load relay test.

Switchgear Installation & Testing: Installation and testing of 110KV GIS, 33KV GIS, 13.8KV GIS, 11KV, 3.3KV and 415V switchgears as per manufacturer instructions (MI), Stability & Scheme verification testing of Switchgear’s HV, MV & LV. Current Transformers & voltage transformers testing with CT Analyzer (VTs, CTs). Protection Relays, Protection CTs, Metering CTs, Testing, Primary Injection & Secondary Injection Testing, Local Control Station, Earthing System, Lightening Protection System, Small Power & Lighting System, Cubical contact resistance test, Phashing check between busbar side & cable side with MCCB closed, Earth leakage protection test {CBCT), Auxiliary contact function test, Phase over current test, Under voltage test, Current imbalance test

Motors Testing: Winding Resistance, PI Index Test, Solo Run Test & performance testing, LCS, DCS, Emergency stop Functional check of Motors.

UPS & Invertors: Installation of UPS Panels, Battery Isolators and Battery Banks. UPS Functional & performance test under load condition, Battery charging & discharging test. 24VDC, 48VDC, 110VDC, 240VAC UPS & Battery Charger System.

Electrical Power, Control Cables: HV, MV, LV Cables Laying & IR Testing, Hi Pot Testing, Torque Testing, cable jointing & Contact Resistance Testing as per Data Sheet.

HVAC SYSTEM: Installation of HVAC units, dampers and control systems. Testing of all systems as per project specifications.

Lux measurement test of lighting for process and non-process area.

Plant earthing system and Lightning protection system Installation & Testing.

QUALITY CONTROL:

I thoroughly understand the entire QA/QC function and capable of handling Electrical & Instrumentation activities. Fully familiar with all Standards (IEC, IEEE, API, NEMA, NEC, BS and ISO standards)

Ensure that material and equipment are correctly received, stored, preserved and handled.

Ensure the preparation of the QA/QC discipline dossier for final handover to the Client, verify the correct implementation and application of the database/spreadsheet for Quality inspection and test report tracking and registration.

Ensure proper Non Conformity detection and recording, as well as relevant corrective actions implementation.

Verifying the material certification, product certification, manufacture data book and other quality records to ensure that the document meets the specified requirements.

Prepare surveillance reports about any deficiencies in site and send to all concerned Engineers for rectification and if no action taken transfer this to OSDR / NCR after discussion with QA/QC Manager.

Ensure that an effective and efficient Quality/HSE Management System is established, implemented and maintained in the Construction Field to achieve these objectives.

Make sure that all ITP, QCP, QCF, MS, QC Procedure and other relevant projects documents are followed through during inspection and compliance with project specifications, IFC/AFC drawing and follow the International Standards and Inspections being carried out as per planned schedule.

Review Contractor’s submittals Inspection test plan (ITP), Quality Control Plan, Quality Control Forms, Method Statement relevant QC documents and ensure that all Inspections being carried out as per approved documents.

HSE: I have handsome SAFETY awareness against personal safety as well as plant safety, Housekeeping, uses of Personal Protective Equipment (PPE), Confined Spaces and Area Classification. I have attended HSE Training courses like Working at Heights, H2S Awareness Training and HSE Management Training. Involved in preparing Job Safety Analysis and Risk Assessment.

Codes & Standards: I am well familiar with International codes & Standards like ISA, IEC, IEEE, API, NEMA, NEC, BS and ISO standards. Familiar with the following Saudi Aramco Standards (SAES, SAMSS, SAEP, SAER, GI STANDARD).

Area Classification: I have good knowledge and working experience in respect of Hazardous Area Classification, Ingress Protection (IP) rating and Temperature ratings, gases groups according to International Standards like ISA, BS, IEC, NEMA etc.

PTW: I have good knowledge and working experience according to PTW instructions. Sound knowledge of Cold, Hot & Spark Potential PTW’s.

CATHODIC PROTECTION SYSTEM:

Impressed Current (ICCP) and Sacrificial type Cathodic Protection systems, Installation of MMO Piggy back anode, TR rectifier Unit installation & its testing, MG Anode for temporary CP, Big Fink, CMTP, CTP, PCR, AJB, NJB, STP, CPTR, EBB, Zinc ribbon anode, Grounding cell, Surge Diverters, Pin Brazing and Termite welding etc.

Pipe to soil potential testing (PSP) surveys.

Supervision of deep well anode installation using CS and PVC casing.

Supervised of CIP survey (Close Interval Potential) and DCVG (DC voltage gradient) survey for 48” & 24” gas pipeline.

Involved in Swing Potential test, Natural Potential survey for gas pipeline.

INSTRUMENT, CONTROL SYSTEM & TELECOMMUNICATION SYSTEM:

General Instruments: Conversant with Pneumatic, and Electronic Instruments like Differential Pressure, Level, Temperature Flow Vacuum Transmitter, Control Valves, Controllers, Pressure, Temperature, and Flow & Level Switches. Turbine flow meter. Routinely calibrated & configured smart series Instruments with HART Communicator and SFC also good knowledge about the workshop calibration Instruments.

Fire & Gas Instruments: Experienced in Installation & Operation of High Sensitivity Smoke Detection System of Kidde Fire Protection. Testing of F&G System including detectors GDT’s FDI’s HD, SD, HSSD system, FACP, Energen and MCL alarming system according to cause & effect matrix. Acquired experience of operation and maintenance of F&G Instruments like IR/UV Flame Detector, Line of Sight (open path) Gas Detector, Point Gas Detectors, Manual Call Points, Smoke/Heat Detectors, Beacons and Sounders and Building Fire & Security etc.

Control System: Have a good command to work on PLC, DCS; F&G System (Safe Guard ABB) based instrumentation. Conducted loop Checking, Cause & Effect Checking, Modified loops and resolved operational problems of PLC (Siemens, Allen Bradley, GE Fanuc and DCS (Fisher Rosemount, Honeywell TDC 3000).

Foundation Field bus: Experienced in Foundation Field bus System of Yakogawa (CS 3000) and FF Instruments. Familiar with basic fundamentals of Foundation Field bus System (Installation, Cabling, Calibration, Loop testing etc.).

Instrument Cables: Instrument cables Laying, Glanding & termination, IR Testing.

Fibre optic: Good Knowledge of fibre Optic Cable Laying, Splicing & Testing, End to End Testing of both type (single mode & multi-mode FOC). Witness of Fiber optic OTDR test @ 1550nm & 1310 nm (Optical time domain reflector) and Splicing with fusion arc splicer.

Vibration Monitoring System: Worked on Vibration Monitoring System of Bentley Nevada 3500 series. Installed Vibration Probes, checked probe health and Probe Characteristics.

Analysers: Installed, operated and maintained Analysers like Hydrocarbon, Moisture, Oxygen, Conductivity, and pH/ORP Analysers and Gas Chromatographs.

Calibration of Equipments: Calibration and testing of Instruments prior to installation. Utilized hydraulic Pressure Calibrator (Ametek JOFRA, Druck, and Giussani), Pneumatic Pressure Calibrator (Ametek JOFRA, Druck), MLC (JOFRA, Honeywell, Fluke, and Eurotron), Temperature Calibrator (JOFRA), Manometer, Dead Weight Tester (G.H. Budenberg, Ametek JOFRA), and HART Communicator (ABB, Honeywell, Rosemount, Fuji, and Yokogawa) Flue Gas Tester, Proximity Switch Tester, RTD Calibrator for routine



Contact this candidate