Post Job Free

Resume

Sign in

Project Customer

Location:
Mumbai, MH, India
Salary:
1000000 P.A.
Posted:
October 13, 2017

Contact this candidate

Resume:

Chandra Narayan

Add: ***, Gandhi Nagar, Unnao

Pin Code: 209801 (Uttar Pradesh)

Contact No: +919*********, +919*********

Email: ac2qnr@r.postjobfree.com

Email: ac2qnr@r.postjobfree.com, ac2qnr@r.postjobfree.com

Skype Id: chandra.narayan4

Objective: To work with cultural environment and to get the desired responsibilities in the organization, where all my formal education and technical skill will always exploit.

Engineer - Exp. 9.2 Years / Looking challenging opportunities in the field of IEC61850/IEC 60870-5-103/101/104 /Modbus Protocol/BacNet Protocol/Tele Communication (GPRS/GSM SCADA System)/Utility/BMS/PMS/Facility Management System (FMS)/Power Distribution & Transmission Field. Basic knowledge of OPC Server /SQL Server/Virtual Server networking and different type of router.

Total Experience: 9.2 YEARS.

1. Current Org. Employed by: Aakriti Engineers (From 5 Dec,2016 to still)

Current Designation: Sr. Site Engineer (Electrical)

Current Job Location: Dadar (Mumbai) Handling RBI Project (BMS/ELCTRICAL/SCADA/CCTV)

Curent CTC : 7.0 Lacs INR P.A. Approx (Included With Fooding & T.A.)

Expected CTC: 10 Lacs to 11 Lacs P.A.

Pass Port No.: H4321924 (Valid Up To 20.4.2019)

• Notice Period: 10-15 days.

SKILLS:

• Automation in HMI, DAS,SIEMENS PLC (S7 300, S7 400, S71200 PLC CONTROLLER) USING SIMATIC MANAGER & TIA Portal Software, ALLEN BRADLEY using ROCKWELL Rs Logix 500 PLC CONTROLLER.

• HMI SCADA RTU Panel Testing, Installation, commissioning & Training.

• Inspection, Erection & commissioning, General Maintenance for HT & LT Drives, HT & LT Panels, LT & HT Breakers, Motor & Substation Automation.

• IEC-61850/60870-5-103 /101/104 Protocols by Using Kalki Gateway Software “Easy Connect”. Model SYNS2000S6R1 for IEC-101 protocol and SYNCS2R1OEM module for IEC 104 Protocol.

• Various Relay ie. Siemens Relay (7UT61, 7SJ803 &7SA610), MiCOM, SAIL Relay integrated with SCADA Software based on IEC 61850 and IEC103 protocol.

• To establish the communications troubleshooting and networking as per the project requirement for Drives, PLCs, SCADA & various industrial devices. (Hardware & Software using Modbus-RTU, Modbus- TCP, Profibus, Profinet, RS232/RS485 Protocols).

• Interfacing Energy Meter L&T ER300P/Secure (Elite) with SCADA V3 S/W (Ashida Electronics Pvt Ltd) using Modbus Protocol.

• Interfacing GSM MODEM (Vision Tech GD-82) with SCADAV3 S/W (Ashida Electronics Pvt Ltd).

• Familiar to SDH, PDH, STM-1(Synchronous Transport Module 155mbps), STM-4(622mbps), STM- 16(2.5Gbps), STM-64(10Gbps).

• Familiar to MiCOM Agile V1.0.0 S1 (Alstom) Relay Software.

• Familiar with explosion proof electrical equipment used in Hazardous area.

• Familiar to EX equipment (Motors, push buttons, Junction boxes & lighting fixtures) and confirm suitability as per Hazardous area classification.

• Familiar with TMW Software (Used for Different Protocol in SCADA Automation).

• Interfacing GPRS SCADA SYSTEM GSM Modem (Vision Tech GD-82) With SCADA V3 S/W using Tunneling Protocol GTP.

• Familiar with SLDC (Load Dispatch Center).

• Project Planning, Execution & attend Technical Seminars.

• Power Operation and control system,Industrial Panel testing.

• Cable Scheduling as required for Project work.

• Basic knowledge of OPC-DA Server /SQL Server/Virtual Server networking and different type of router (ADSL 2+ Router GLB-802C Series D-Link router).

1.AAKRITI ENGINEER (A Company of Construction Work): RBI PROJECT: DADAR (WEST)

RESPONSIBILITY:

Project documentation work.

Installation, testing & commissioning of LT Electrical Panel, CT/PT/MCCB, MCB, DG, SMDB,DB & all ELV major equipment’s like Fire Alarm Panel, PA rack, CCTV / Security servers, Switches, Router, BMS servers, Audio Video Equipment.

Layouts (Equipment layout, Grounding layouts, Lighting layouts, Conduit layouts for power/control/lighting cables).

I/O lists, Instrument data sheets.

Conduit and Conductor schedules.

Set project timeline.

Monitor project deliverables

Update relevant stakeholders or team members on the project progress.

Comply with all applicable standards, policies, and procedures, including safety procedures and the maintenance of a clean work area.

•Material Testing Procedure (MTP) preparation.

•Assure that electric areas and equipment’s are risk free of accidents.

•Lead the team & achieves the goal of organization with customer satisfaction also take care for BOM creation for the project

•Prepare, coordinate & implement the electric maintenance schedule for all equipment and maintain the maintenance results in the filling system.

•Review the electric spare parts requisitions that been raised by engineering teams. Confirm and approve the required parts.

•Co-ordination & to manage Main contractor and sub-contractor representative for timely completion of project with desired quality with norms.

2. SIEMENS LTD (Kalwa)

Previous Organization Employed by: SIEMENSE LTD, KALWA. Thane (MAHARASHTRA). INDUSTRIAL AUTOMATION (SIMATIC MANAGER VER: SP 2.3) Using Symatic S7 400 PLC controller.

Period: 18 November, 20013 up to 17 Nov 2016.

Previous Designation: (INTEGRAL PLANT MAINTENANCE ENGINEER) SCADA OPERATION & Control/Power Management System/Facility Management System(FMS) /BMS.

Previous Job Location: Chatrapati Shivaji International Airport T2 Terminal Andheri (East), Mumbai INDIA

RESPONSIBILITY:

Project documentation work & MIS preparation.

Power Distribution, control operation & monitoring CB status and Load analysis at Chatrapati Shivaji International Airport T2 terminal, Mumbai 33/11kV HT/LT {total 9 HT substation (11kV) and 7 LT substation (415V)}. All substation remotely operated through SCADA PLC AUTOMATION & 6 DG (Each rating: 3MVA) also remotely monitored through SIEMENS PLC SCADA System). Also maintenance of HT/LT panel,ACB & VCB as per time schedule.

Operation and Maintenance, Monitoring Temperature of AHU System & installation work (MEP1 UP to MEP13).

Monitor energy consumption and design methods for conservation and optimization of energy.

Responsible to ensure that proper logbooks are maintained for the various equipment’s. Also ensure that the preventive maintenance schedules are meticulously followed.

Support all engineering project functions such as detailed design review and approval for new M&E installations and auditing of deliverables throughout the course of implementation to ensure quality of workmanship, and adherence to specification.

Implementation / management of maintenance contracts pertaining to Building Services & Critical Systems installations.

Discuss heating-cooling system with users to improve the effectiveness of Air conditioning.

Make periodic checks of completed repair and maintenance work to ensure that the established standards have been met

To lead team in maintenance, troubleshooting of instrumentation and control systems and its components in utilities and refrigeration plants as SCADA, HMI, PLC Controllers, SCADA RTU Panel VFD, Sensors, Energy Management System and implement corrective actions to ensure its reliable operation.

To lead Refrigeration and Utilities Teams in the implementation of TPM/WCM, activities like preparation and presentation of Kaizen, Autonomous Maintenance, Improvement Projects, etc.

To ensure that field devices, instrumentation systems, communication networks and interfaces are working properly does, modifications, if need be, to improve its operational reliability and performance.

Comply with all applicable standards, policies, and procedures, including safety procedures and the maintenance of a clean work area.

Installation of different type of sensor Co2 Sensor/Humidity Sensor (HE-67N2-ON00P Johnson Control)/CFM Sensor/SA Damper Actuator (Belimo SM24-SR 24 AC/DC) Temperature Sensor/CFM SENSOR/Thermostat.

Planning for energy saving of AHU by manual scheduling made off the AHU or decreases frequency of VFD or by decreasing SASP by DDC panel.

DDC Panel Installation & Testing.

Shift Management, Prepare Shift Roaster monthly.

Carry out daily Tool Box Talks meeting with technicians.

VAV/FCU/CAHU/AHU/OHU, Temp monitoring and control operation & by using Johnson Controls {NCE-2567 Controller, IOM-1711, IOM-4711 (BacNet RS-485 MS/TP 3-wire FC Bus)} S/W and Honeywell S/W. Johnson Controls IOM controller operates on RS-485 BacNet Master Slave/Token Passing bus and Integrated in to web based Metasys System. (Processor H8Sx166R Renesas 32-bit Micro Controller,1MB flash memory,512MB RAM).

Lead the team & achieves the goal of organization with customer satisfaction also take care for BOM creation for the project

Prepare, coordinate & implement the electric maintenance schedule for all equipment and maintain the maintenance results in the filling system.

LCMS observation /control/ monitoring Light Time Scheduling based on BacNet Protocol by using Envision Manager Software (Phillips).

VFD (Danfoss Make) VLT HVAC Drive FC102, 1.1 to 90kW uploading and downloading data to LCP (Local Control Panel) maintenance, Testing & installation.

Review the electric spare parts requisitions that been raised by production and engineering teams. Confirm and approve the required parts.

Supervise, direct and support all personnel in Electric Section/Lighting Section for closet light On/Off.

Prepare Bi-Monthly report of maintenance activities, break down and electric consumption.

Assure that electric areas and equipment’s are risk free of accidents.

Co-ordination with other MEP services such as HVAC, Plumbing, Firefighting, ELV system etc & other trades like civil, interiors, facade etc.

Co-ordination & to manage Main contractor and sub-contractor representative for timely completion of project with desired quality with norms.

PHILIPS Dynalite Relay controller DDRC1220FR-20 (12 Channel) 100 to 240V 50/60 Hz,0.25A control operation and maintenance for LCMS system & DALI Controller DBC516-FR using for Chandler Light control operation based on BacNet Protocol.

3Previous Employee: ASHIDA ELECTRONICS PVT LTD Thane.Maharashtra (India) (A Company of Control Panel,RTU Panel, Relay Protection & SCADA Automation).

Period: 28 July 2008 up to 15 Nov 2013.

Previous Designation: (Sr. Project Engineer.) SCADA RTU Panel, SCADA Software Installation (SCADA V3), CRP Installation and Commissioning Engineer, Maintenance Engineer.

Previous Job Location: PAN INDIA as per Project & client requirement.

RESPONSIBILITY:

•Project documentation work.

•HMI,DAS, SCADA RTU Panel, Control Relay Panel Testing, Installation, commissioning, Maintenance Troubleshooting of problems and resolving issues.

•SAS Configuration for Protection Relay (241S Self power relay, Self Power Relay 241C, ADR 211E, ADR 219B, APFO/2 etc.), Feeder Control (Close/Trip), Isolator (Open/Close).

•SCADA V3 S/W Installation (Com Explorer, Port Management Suite Port Configuration for Moxa

DE-211 & Nport 5150).

•AFRTU (Ashida Feeder Remote Terminal Unit using FCCM/5B-FDR Controlling operation and FCCM/3B- for Status (Communication card) Based on GPRS Tech.under observation and utilize for ABB RMU.

•Cable Scheduling as required for Project work.

•To establish the communications and networking as per the project requirement for Drives, PLCs, SCADA & various industrial devices. (Hardware & Software using Modbus-RTU, Modbus- TCP, Profibus, Profinet, RS232/RS485 Protocols).

•Interfacing Energy Meter L&T ER300P/Secure (Elite) with SCADA V3 S/W (Ashida Electronics) using Modbus Protocol.

•Prepare Factory Assessment Test (FAT) report.

•Project Planning & Execution, Site Inspection.

•Liasoning with the client as per requirement.

•Co-ordination & to manage Main contractor and sub-contractor representative for timely completion of project with desired quality with norms.

•Installation of upgraded SCADA System (Noida Power Company Limited, Greater Noida 33/11kV S/S, NIT Hamirpur 66/11kV S/S, Ardhapur 132kV S/S) as per requirement on site.

•Recently handling project: Noida Power Company Ltd (Greater Noida, U.P.) SCADA based on IEC104 protocol, Jain Irrigation Ltd.

Jain Irrigation Ltd. (Jalgaon) 8.5 MW Photovoltaic Generating Power Plant (DAS, IEC 104 Protocol based SCADA). ACCIL (Khopoli) (IEC 61850 based SCADA), ThyssenKrupp (Nasik) (IEC 103,101 Protocol based SCADA System, Namco (Khopoli)(For HMI IEC 101 and IEC 61850 for Alostom Relay).

•Project Details:

Noida Power Company Limited. (Greater Noida U.P.)33/11 kV S/S (Jan 2013 to July 2013)

•Project: Project: SCADA Automation of 12 Substation (33/11kV) NOIDA POWER COMPANY LIMITED.

•Customer: Ashida Electronics’ Pvt.Ltd.

•Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment with existing systems by Using IEC 104 Protocol. SCADA SYSTEM Installation & commissioning.

Lokmagal Sugar 132kV S/S Solapur (9 April 2012 to October 2013.

•Project: Lokmangal Sugar Ltd Substation, Solapur

•Customer: Lokmangal Sugar Ltd. (SOLAPUR)

•Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment with existing systems. Using IEC61850 to IEC 101 Protocol. SCADA SYSTEM Installation & commissioning SEIMENS Relay communication based on 61850 protocols

•220kV ISMT KURLA SUBSTATION, HIGENGHAT (WARDHA) April 2011 to 2 Sept 2011.

•Project: ISMT Ltd. from 220KV/132KV Hinganghat Substation, Dist. Wardha.

•Customer: ISMT LIMITED 40 MW Coal based captive Thermal Power Plant.

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA

•Equipment with existing systems. Using IEC61850 to IEC 101 Protocol. SCADA SYSTEM Installation & commissioning.

SCADA Trainer (Mumbai). Jan 2010.

•Project: Western Railway Mumbai.

•Customer: Western Railway Mumbai.

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawing and Interfacing SCADA Equipment’s with existing. systems

Punjab Tractor Limited. (August, 2009-2010).

•Project: Punjab Tractor Limited.

•Customer: Punjab Tractor

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA

•Equipment’s with existing systems.

H.P. (NALAGARH Project), 66kV Substation Cadabury India Limited, Ankur Drugs & Kangra

Steel(GSM SCADA) Sept 2009 to April 2010

•Project: Cadabury India Limited/ Ankur Drugs & Kangra Steel

•Customer: Cadabury,Ankur Drugs & Kangra Steel Undertaking Supply from (H.P.S.E.B)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA (GSM

•Technology based) equipment’s with existing systems. We are using Two GSM Modem (Vision Tech GD-82 series) interfacing with our Feeder Control Communication Module (FCCM). Communication Based on Data Channel number of provided SIM.

H.P. (BADDI Project), 66kV Substation (Jan 2010 to Oct 2010)

•Winsome Textile, Radient Steel & Gilbert Ispat (GPRS SCADA)

•Project: Winsome Textile

•Customer: Winsome Textile (H.P.S.E.B)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA (GPRS

•Technology based) equipment’s with existing systems. We are using Modem (Vision Tech GD-82 series) interfacing with our Station Controller ADR 200 Series. Communication Based on Static IP Address Connectivity with Internet TCP Proxy Server.

•Project: Radient Steel

•Customer: Radient Steel (H.P.S.E.B)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA (GPRS Technology based) equipments with existing systems. We are using One GSM Modem (Vision Tech GD-82 series) interfacing with our Station Controller ADR 200 Series. Communication Based on Static IP Address Connectivity with Internet TCP Proxy Server. ADSL 2+ Router (GLB-802C Series) D-Link router.

•Project: Gilvert Ispat

•Customer: Gilvert Ispat (H.P.S.E.B)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA (GPRS

•Technology based) equipment’s with existing systems. We are using One GSM Modem (Vision Tech GD-82 series) interfacing with one Station Controller ADR 200 Series. Communication Based on Static IP Address Connectivity with Internet TCP Proxy Server. ADSL 2+ Router (GLB-802C Series) D-Link router.

Western Railway: SCADA (25kV) Borivali to Virar,May 2009 to August 2009

•Project: Western Railway Mumbai.

•Customer: Western Railway Mumbai.

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment’s with existing systems. In this we are using two Modem (Team Link 2001S) SCADA which based on FSK (600db/1200db) half Duplex Technology and Station Controller (ADR200A).In this project We are using SPORT protocol (Special Protection for Railway Traction IEC 101) and interfacing with S/W (Ashida Electronics) Survey/ SCADA RTU Panel mounting (TSS/SSP/SP) 25kV S/S Western Railway SCADA RTU Panel Installation and commissioning .

Western Railway: Borivali to Church Gate SCADA (Aug 2009 to Dec 2009)

•Project: Western Railway Mumbai.

•Customer: Western Railway Mumbai.

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment’s with existing systems. In this we are using two Modem (Team Link 2001S) SCADA which based on FSK (600db/1200db) Half Duplex Technology and Station Controller (ADR200A).In this project, We are using SPORT protocol (Special Protection for Railway Traction IEC 101) and interfacing with S/W (Ashida Electronics). Survey SCADA RTU Panel mounting (TSS/SSP/SP) 25kV S/S Western Railway SCADA RTU Panel Installation and commissioning

•. Nuclear Fuel Complex, Hyderabad (Jan 2008 to Nov 2009)

•Project: Nuclear Fuel Complex

•Customer: Nuclear Fuel Complex (NFC)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment’s with existing systems. In this project, we have communicated SPAJ 140C Relay (For O/C Earth Fault Protection ABB) interfacing SPA-ZC-21/SPAZC-22 ABB make optical fiber converter and Kalki Converter for protocol (IEC-60870-5-103) using SCADA V3 S/W (Ashida Electronic

Jamde & Valve S/S 220/33kV S/S, Dhule (Maharashtra) Nov 2007 to Nov 2008

•Project: Valve (220/33kV) S/S

•Customer: MSEB (Dhule)

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment’s with existing systems. Communication of Argus Relay using (IEC-60870-5-103) Protocol. For Energy Meter Secure (Elite) using Modbus Protocol. For feeder controlling operation we are using ASCADA Protocol.

•Project: Jamde (220/33kV) S/S (Nov 2007 to Nov 2008)

•Customer: M.S.E.B. (Dhule) Maharashtra.

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA Equipment’s with existing systems. Communication of Argus Relay using (IEC-60870-5-103) Protocol. For Energy Meter Secure (Elite) using Modbus protocol.For feeder controlling operation we are using ASCADA Protocol.

Vadodara SCADA Trainer (Gujarat) Dec,2007 to Oct, 2008

•Project: Western Railway Vadodara.

•Customer: Western Railway

•Client: Ashida Electronics Pvt. Ltd.

Responsibilities: Understanding Customer Drawings and Interfacing SCADA

Equipment’s with existing systems.

Technical Skills:

Substation Automation: Substation Automation System (SAS): using IEC 61850 Protocol

At 33/11kV Substations & 220/33kV Substation Using SCADA V3 S/W Developed by Ashida Electronics.

Working Experience in 220kV S/S, 33/11kV S/S, 66kV S/S, 132kV S/S & familier with HT/LT panels.

Power System & Switchgear: Familiar with Transmission and Distribution of Power. Decent knowledge of Power Transformer, Current Transformer, Potential Transformer, Circuit breaker, Isolators and Protective Relays (Electromechanical, static & Numerical relay) of L& T,Areva, Siemens,ABB,Ashida,Biecco Lawrie. Etc.

Communication: Decent knowledge of Optical Fiber(SM/MM) system, Fiber

Management System, Fiber Splicing, OTDR, Frequency

Orientation Team Link & Antenna & Antenna Planning

2001S Modem Based on FSK half-duplex Technology.

Familiar with SLDC (Load Dispatch Center), GPRS/GSM

Technology based SCADA System.

Computer Networking: Knowledge of OSI Layer, TCP/IP, Local Area Networking (LAN).

Standard Interface Devices like RS232, RS485, RJ45 etc. and Ethernet. Familiar with Protocols IEC 61850 /IEC 60870-5-103, IEC 101/IEC 104 & Modbus. Familiar to SQL Server /OPC-DA SERVER.

SPORT Protocol (Special Protection for Railway Traction)

IEC-101 Protocol.

Operating System: MS DOS, Windows7/10/ XP/NT/2000/98

Other Packages: MS Office, C++ language, Visual Basic & HTML,

Hyper terminal.

Project Undertaking: Uninterrupted Power Supply On line.

Training: PLC INDUSTRIAL AUTOMATION training of all types of PLC Logic Controllers taken from Precon Automation Training Institute (ISO 9001:2008 Certified Company) from 16-06-2014 to 11-08-2014.

Educational Qualifications:

Bachelor of Technology (B. TECH): Electrical Engineering from Maharana Pratap Engineering College, Kanpur affiliated to Uttar Pradesh Technical University / UPTU in 2007.

Personal Performa:

Father's Name: Shri, Chandra Shekher

Date of Birth: Dec 1, 1981

Nationality: Indian

Language Known: English, Hindi, Marathi, Gujrati, Punjabi, Rajasthani

Hobbies: Observing wild life & nature, listening to music, Playing

Cricket, Reading Technical books.

Declaration:

I certify that the above information is correct and true to the best of my knowledge and belief. Further declare that I have never been arrested / prosecuted and convicted by criminal court or involved any other case registered by the police.

Date:OCT,2017

Place: Navi Mumbai, (Maharashtra) (CHANDRA NARAYAN)



Contact this candidate