Eugene Kolpakov **** Stone Valley Road
Alamo, CA 94507
Preferred Phone:510-***-****
Home: 925-***-****
E-mail: **********@*****.***
Objective:
Professional Summary:
Experience: Stationary Engineer – Journeyman position
More than 10 years’ experience as a Stationary Engineer in data centers, high-rise buildings, hotels, schools, semiconductor manufacturing facilities.
CFC (refrigerant recovery license Type Universal), High Rise Fire Safety Director, Electrical Safety, Fire pump testing certifications.
Strong "hands-on" troubleshooting skills and extensive experience in HVAC, building control ( Johnson Controls Metasys, Siemens Insight), electrical distribution, refrigeration and air conditioning, boilers, plumbing, water treatment, and life safety.
5 years’ experience as a fire alarm technician.
October 2014-current - California School for Deaf in Fremont
Stationary Engineer
• Preventive maintenance and repair of fans, pumps, AC units, heaters, boilers, kitchen equipment, plumbing.
January 2014-August 2014 - Experis at Amazon.com in Hayward
Data Center Operations Engineer-temp
Maintaining, operating and hands-on troubleshooting Data Center Critical Facilities equipment, which includes all ATS units, stand-by diesel generators and related fuel systems, 3-phase electrical systems that include switchgear, UPSs, PDUs, wet cell batteries and associated systems, CRAHU, centrifugal chillers, cooling towers/water chemical systems, air handlers and associated systems, pumps, & motors.
August 2013-December 2013 - Port of Oakland
Equipment Systems Engineer-temp
• Preventive maintenance and repair of fans, pumps, AC units
• Electrical, lighting, door and lock repair and installation
•Boiler repair and water treatment
April 2010-May 2013 - One Market Plaza in San Francisco
Stationary Engineer Local 39 – Journeyman
• Preventive maintenance, repair, and rebuilt of fans, pumps, AC units, heat pumps, steam traps, PRV valves
• Operation and scheduling Siemens Insight Apogee Energy Management System, programming VAV box controllers(ATEC)
• Replacement of toilets and urinals, Sloan flashometer rebuilt
• Water treatment of 2 high–rise buildings
• Troubleshooting and repair of fire alarm system, testing assistance, in-house testing and cleaning, batteries replacement
• Electrical, lighting, door and lock repair and installation
• Fire pumps(weekly), emergency generators, ATS testing
• Locks, doors, door openers, and door closers repair
• Induction units+VAV boxes repair, balancing, t-stats calibration
November 2008- March 2010 :Wells Fargo Data Center in Fremont
Stationary Engineer Local 39 – Journeyman (temp)
• Preventive maintenance of fans, pumps, AC units, boilers
• Projects: replacement of pneumatic FVAV/VAV controllers with DDC controllers, automatic flashometer upgrade
• Test-run of fire pumps, emergency generators, water treatment
• Electrical repair using single line diagram, conduit run, fixtures and radiant heaters installation
August 2005-October 2008:555/575 Market Center at San Francisco
Stationary Engineer Local 39 – Journeyman
• Preventive maintenance, repair, and rebuilt of fans, pumps, AC units, heat pumps, steam traps, PRV valves, cooling towers
• Operation and scheduling 2 Energy Management Systems- Johnson Controls Metasys and Siemens Insight
• Programming and reprogramming VAV box controllers(Siemens ATEC, TEC,JC UNT,JC VAV)
• Projects: installation of heating water valves for induction boxes, water flow switches, drain valves replacement on all floors, VFD installation
• Replacement of toilets and urinals, Sloan flashometer rebuilt
• Water treatment of 2 high–rise buildings
• Troubleshooting and repair of 2 fire alarm systems, testing assistance, in-house testing, batteries replacement
• Electrical, lighting, door and lock repair and installation
• Test-run of fire pumps and emergency generators
• Locks, doors, door openers, and door closers repair
• Induction boxes and VAV boxes repair and balancing
June 2004 –July 2005 :ABS @ Applied Materials, Santa Clara
Stationary Engineer Local 39 – Journeyman
• Conducted preventive maintenance, troubleshoot, repaired, and operated building equipment and systems: HVAC equipment, Building Air Supply and Distribution, 2 Energy Management Systems- Johnson Controls Metasys and GE Symplicity, DI Water, Hot Water, Clean Dry Air, Chilled Water, Industrial Waste Neutralization
February 2004 – June 2004: Hyatt Saint Claire Hotel, San Jose
Stationary Engineer Local 39 – Journeyman (temp)
• Repair and service of Guest Room Heat Pumps, A/C units, Chillers, Cooling Towers, Boilers, Air Handling Units
• Electrical, lighting, plumbing, and lock repair and installation
• Repair of Fire Alarm System
2003 –2004: Able Engineering Services, Oakland City Center
Stationary Engineer Local 39 - Journeyman (temp)
• Maintenance and repairs of HVAC systems, VAV's
• Electrical, Lighting, Plumbing, and Lock Repair
• Conducted water treatment of two high-rise buildings
• Team leader of BEMS retrofit project - replaced 600 VAV box controllers with reprogramming and troubleshooting
2000 - 2002: IntelliSec, San Leandro, CA
Senior Installation/Service Technician
• Supervised and performed Installation and repair of Fire Alarm Panels and Building Management Systems in high-rise buildings
• Provided hands-on directions and training for other technicians
1997 - 2000: Electronic Detection Systems, Inc, San Leandro, CA
Installation/Service Technician
• Serviced, repaired, and installed a variety of Fire Alarm Panels and Building Management Systems in high-rise buildings
Education:
Fire pump testing certificate-current
CFC certification (EPA Type Universal).
High Rise Fire Safety Director Certificate
Low Voltage Electrical Safety Certificate
Sprinkler Systems Inspector Certificate
Stationary Engineers Local 39 Training Center at San Francisco:
2010-VFD-seminar, PLC programming class, Heat Pumps-seminar, Hands-on Refrigeration Lab-seminar
2008- High Rise Fire Safety Director Certification Renewal class, Welding class at Stationary Engineers Local 39 Training Center
2003 – Boilers and High Rise Fire Safety Director Certification classes at Stationary Engineers Local 39 Training Center at San Francisco.
2002 – Refrigeration and Air Conditioning.
B.S., Electronics manufacturing- Minsk Radiotechnical Institute in Belarus