KALYAN CHAKRAVARTHI. G.A
Position applying for: Sr. QA & QC Surveyor (Mechanical, Painting, Welding & NDT)
CSWIP 3.1, BGAS Gr: 2 (TWI), Lead Auditor ISO 9001-2015 (IRCA) & ASNT NDT Level-II
H.No: 6-9, Near Chowdi,
Saroornagar, Hyderabad 500 035
Mobile: +91-901*******
Email: ac1xwr@r.postjobfree.com
Professional Summary
A Dynamic Professional with nearly 15+ Years’ Experience in the field Of Inspections,
Manufacturing, Heavy Structure, Various Structural Welding Inspection’s & Ship Buildings Raw Material.
Well versed with Welding, Destructive and Non-Destructive, Mechanical Inspections. Establish and Review of procedure like TDR, TQ, NDT, QAP’s, ITP’s, ATP's, SOW, WMS, PWHT, WPS & PQR.
Proficiency in managing quality related activities involving Erection, in-process inspection and Final inspection.
Conversant with International codes & Standards and Clients Specifications.
An effective communicator combined with flexible and detail oriented attitude with the ability to interact effectively with people at all levels.
EDUCATIONAL QUALIFICATION
Diploma in Mechanical Engineering in the Year of 1999 from Vasavi Polytechnic College, Banaganapalle, (State Board of Tech. Education & Training, A.P.) with aggregated percentage of 61.0
PROFESSIONAL ENHANCEMENTS (CERTIFICATIONS & TRAININGS)
Welding Inspector, CSWIP 3.1, Certificate No: 109723, TWI, UK.
Date of expiry : 30 June 2021
Painting Inspector, BAGAS- Gr. 2, Certificate No: 256236, TWI, UK.
Date of expiry : 17 Nov 2021
Lead Auditor ISO 9001-2015 (IRCA) from M/s Bureau Veritas Certification India.
ASNT Level II in
Ultrasonic Testing (UT)
Magnetic Particle Testing (MPT)
Liquid Penetrant Testing (LPT)
Radiography Testing (RT).
FUNCTION STRENGTHS
WELDING PROCESS : MMA, GMAW (MIG/MAG), GTAW, SAW, SMAW
TESTING : Mechanical, Hydro, Pneumatic, NDT.
DOCUMENTATION : Establish and Review of procedure NDT,QAP’s,
ITP’s, ATP's, SOW, WMS, PWHT, WPS & PQR
Name of Organisation
Position held
Duration
(Month & Year)
M/s Bureau Veritas India Pvt Ltd
Mahaveerlok, Himayatnagar, Hyderabad
Mechanical Surveyor
09 May 2011 to 09 May 2016
M/s Defence Research Development laboratory Kanchanbagh, Hyderabad
Contract Engineer
06 Jan 2011 to 30 April 2011
M/s Industrial Inspection Services, Mumbai (Worked under Defence Machinery & Design Establishment, Hyderabad)
QA/QC Inspector
2nd April, 2007 – 31 Dec 2010
M/s Defence Research Development laboratory Kanchanbagh, Hyderabad
Contract Engineer
Jan, 2002 – March, 2007
NATURE OF EXPERIENCE
Presently working as a freelancer QA/QC inspector with aplus velosi India.p
Worked as a Freelancer with IR Class for Greenko Projects for inspection of Galvanized Structures at various vendor locations
Visual and Dimensional Inspection carried out for Solar Mounting Module structures at various vendor locations.
Witnessed for DFT, Knife Test, Hammer Test, Copper Sulphate Test and Mass of Zinc Coating on Hot Dipped Galvanized Structures.
M/s Bureau Veritas India Pvt Ltd, Hyderabad
Responsibilities:
Deputed to M/s Reliance Industries Jamnagar for inspection of chemical cleaning of Carbon Steel and Stainless Steel for Process and Oxygen Services.
Reviewed Test Reports of Chemicals, Validation reports of Instruments used for inspection
Verification of incoming Spools/Pipes as per request note
Checked Bath preparation parameter and validation of test coupon
Monitoring of each bath parameters as per Client Specification
Visual inspection with white, UV light and endoscopy inspection were carried out for offered CS & SS pipes / spools
Wipe test carried out on SS Pipes/ Spools for checking traces of oil under UV lamp.
Inspection of Economizer Coils with supporting tubes, Air Box, Evaporator coils with supporting tubes, Panels, Headers etc., carried out at M/s ThyssenKrupp Industries India Private limited as per approved QAP, Drawings, Client Specification :
Reviewed Raw Material Test Certificates and co relation of Heat/Cast numbers and marking on materials with Test Certificates
Visual & Dimensional inspection of tubes, First off Trial Bend (FOT), Weld fit up, alignment of coils on lay out.
Reviewed Radiographic films of Economizer and Evaporator coils
Hydrostatic test of Economizer and Evaporator coils.
Checked for surface preparation and DFT of Economizer and Evaporator coils.
Visually checked for orientation, straightness and Weld finish
Inspection carried out at M/s ITS Pipetech, Cherlapally for HDPE Pipe fittings for Visual, Dimensional and Hydro Pressure test for welded joint for Vatech Wabag for Reliance J3 project.
Tankruck Inspection carried out at HPCL Depots of various areas
Deputed to M/s Orient Cements, Chittapur, Gulbarga for inspection of Structural items
Involved in the inspection of Girders for L&T Metro Hyderabad, at Uppal Depot.
Witnessed Ultrasonic Testing for High Pressure Pipe lines of M/s Adani 5 X 600MW Power Project, Tiroda, Maharastra
Deputed to M/s Adani 2 X 660MW Thermal Power Project, Kawai, Rajastan where field inspection of River intake water pipeline which is around 25kms from power plant.
Reviewed Radiographic films of Pipe line of Turbine Generator area, Intake water pipe line, Cooling tower pipeline, Welder qualification etc.,
Visual & Weld visual inspection carried out at Turbine Generator area, Coal Handling & Ash Handling Units, Stackers, Air Precipitators etc.,
Conducted Welder qualification tests for different positions
Inspection carried out for Heat Exchangers, Surface Condensers, Feed gas mist eliminators, as per approved QAP.
Visual and Dimensional inspection of Tubing, Casing, Coupling of Tubing & Casing, Drill pipes, Witnessed Hardness, Magnetic Particle Inspection of DS 55 Pin, NC-50 Boxes.
Measurement of Coating thickness (Epoxi) for approximately 15,000 Meters of Drill Pipes and Visual Inspection of ID using light method for surface coating, and cleanliness at Oil Country Tubular Ltd (OCTL)
Involved in inspection of Structural Steel, Air Ducts and Duct supports for 3X660MW Power Project (Koradi Thermal Power project) and 2X660MW Power Project (Jaypee Nigire Thermal Power Project)
Involved in inspection of PEB structure for Bangalore Metro Rail at M/s Kirby Build Sys.
Involved in inspection of Low Pressure and High Pressure Heat Exchangers and Surface Condensers for M/s Siemens at GE Godavari
Involved in inspection of Air pre heaters, Dearators and Feed Gas Mist Eliminators, Oil Coolers Etc.,
Carried out inspection of Sleeve and Hub assembly, Foundation Bolts, Rubber(Elastomeric) bearings, DI Suice Valves etc
Performed Galvanized support structures for isolated phase bus duct inspection for M/s. Areva T&D India.
Involved in inspections of transmission & Telecommunication towers at various vendor places.
Performed inspections for Metal Tube Rota meter, Dished Ends, Simplex Filter, etc.,
Witnessed Mechanical testing at different NABL accreditation labs.
PREVIOUS EXPERIENCE
Defence Research & Development Lab, Kanchanbagh, Hyderabad.
Worked as a Contract NDT Engineer in DRDL for a Missile Project Agni for carrying out Radiography, Ultrasonic Testing, Die Penetrant Testing and Magnetic Particle Testing, Ultrasonic Thickness Measurement of Tubes and Visual Inspection.
Industrial Inspection Services (Defence Machinery & Design Establishment)
Preparation of Quality Assurance Plans (QAP)
As a resident QA/QC inspector at Mishra Dhatu Nigam Ltd Hyderabad, assuring the testing of materials as per approved QAP, and performing Visual and dimensional inspection of materials such as Forgings, Castings, Stainless steel and Titanium Tubes, Special grade Weld Consumables (Electrodes, Wires, Flux).
Assuring the testing of material as per approved QAP, and performing Visual and Dimensional inspection, of Non-Ferrous Castings, Forgings and Weld consumables at Non-ferrous Technology Development center, Hyderabad.
Assuring the testing of material as per approved QAP, and performing Visual and Dimensional inspection of Copper and Copper alloys tubes at Kanak Pipe Industries, Mumbai.
Radiography Film Interpretation and report generation of Steel Castings, Nickel Aluminum Bronze (NAB) Castings, Titanium Castings, Aluminium and Magnesium castings and weldments.
Verification and approving the Radiography Testing Procedure and RT shooting sketch.
Assuring the material qualified and checking whether all tests are conducted as per the approved QAP and preparation of Inspection Clearance Note to various consignee.
COMPUTER SKILLS
Operating Systems : Windows, DOS
Office Packages : MS-Office (Word, Excel, PowerPoint)
PASSPORT DETAILS
Passport Number: Z4028151 Date of Issue: 01/02/2017
Location: Hyderabad Date of Expiry: 31/01/2027
REFERENCES:
1)G Gopala Krishna, Deputy General Manager Quality
M/s Greenko Energy Projects Private Limited
Mobile Number: 986-***-****
2)M. Venkat Reddy, Scientist ‘E’,
Head NDED, Defense Research & Development Lab.,
Kanchanbagh, Hyderabad
Mob: 944******* (O): 040-********
PERSONAL DETAILS
Fathers Name : G.A. Prabhu
Date of Birth / Sex : 24/05/1979 / Male
Permanent Address : H.No: 6-9, Near Chowdi,
Saroornagar, Hyderabad 500 035
Marriage Status : Married
Languages Known : Telugu, Hindi & English
Declaration
I hereby declare that all the above information provided by me is authentic to the best my knowledge and request you to be kind enough to give me an opportunity to serve your esteemed organization.
Palce: Hyderabad (G.A. Kalyan Chakravarthi)
Date: