Career Objective

With an experience in the field of Project Handling,Testing and Commissioning& Maitainence of power system products. I look forward for an opportunity to display my skills in the field of Commissioning, Maintenance and Execution of projects related to power systems.

Educational Qualification :

Degree in Electrical Engineering with specialisation in Electronics

Anna university chennai(T.N) (68%) (Full time 2005-2009).

HSc., in Govt Higher Secondary School, Anumandi.

86%(2005)

SSLC in Govt Higher Secondary School, Anumandai.

83%(2003)

Professional Experience

Overall 8.3 years experience as Protection Testing and Electrical Equipment Testing and Commissioning Engineer in Substations & Powerplants at all voltage(Upto 400Kv) levels.

3.6years experience in Gulf Country.

8 month experience in Singapore .

Nature of Works

Testing and commissioning of all Electrical equipment in power System.

Inspection of control and relay panel, preparation of Test Report and power plant and process plant.

Testing and commissioning of control & relay panel for all motor feeder,

Testing and commissioning of power control centre and motor control centre.

Testing of Protective Relays for various needs. Experience with relays.

Over current and earth fault relays

Knowledge of Transformer protection, Transformer Differential Protection, Bus Bar protection, Motor protection, and synchronizing scheme.

Testing of CT, P.T. CVT, Circuit breaker, switch gear and Power Transformer

Trouble shooting of all Electrical circuits, control and protection circuits

Co-ordination with client in As Built Scheme drawing submission, test report submission.

As build cable schedule submission and all site activity to satisfy the customer.

Summary of Professional Experience

Present Employer

1.Working as Protection and Commissioning Engineer in M/s NECE National Excellence for Construction & Energy,Saudi arabia from May 2016 to till date.

Previous Employer

1.Working as Sr,Commissioning Engineer in M/s Carlo gavazzi arabia co ltd, Al jubail,Saudi from Feb 2014 to April 2016 .

1.Worked as Sr.Commissioning Engineer in M/s Voltech Engineers Pvt.Ltd from August 2011 to Dec 2013

2.Worked as Testing Engineer in M/s ABB LTD singapore, singapore from August 2010 to may 2011.

3.Worked as Testing Engineer in M/s Danalakshmi Enterprieses Chennai, india from june 2009 to june 2010.

Job profile: Pre-Commissioning, Commissioning & Maintenance

CAREER HIGHLIGHTS:

Having good exposure in Pre-commissioning & Commissioning, Operation and Trouble shooting of following Electrical Equipment

Commissioning & Maitenance from 415 swgr to 400 KV switchyard

All electrical equipment testing and commisioning like CT,PT,Transformers,HT panels,LT panels and control &Relay panels

Motor control center

Control &Protection panel,Tranformer &H.T.Motor

G.C.B(SF6), V.C.B, A.C.B

Transformer (150KVA-315MVA) with Differential protection and REF protection

Capacitor Bank Testing.

Experience with ALSTOM MICOM Relays

Alstom Relays, P141,142,143.

Alstom Relays Distance protection P543,P546.P443

Alstom Relay differential protection P643.

Alstom relay Breaker failure and auto reclose P841.

Using S1Agile software

Experience with ABB RELAYS

Feeder & Transformer Protection Relays REF 542 plus,REF 610, REF 545, REF 630, RET 630, REF 615 Using PCM software.

Motor Protection relay ( REM 610, REM 615).

Breaker failure protection relay REQ650.REB650,

Distance relay RED 670.

Using PCM 600 2.7 VER SOFTWARE .

Experience with GE Relays

GE Relays C70, Capacitor feeder protection.

GE Relay D60, Distance Relay.

GE Relay F650 feeder protection

Using Ener Visita software.

Experience with TAPCON AND ZIV Relays

6RTV ZIV Relay

Using ZIVER COM,ZIVER CID software

Using MR Suit.

OVERSEAS EXPERIENCE: (Period: May 2016 to July 2017)

Khobar integration facality, khobar,Saudi Arabia.

Testing of all protection and Relay control panels and all kind of relays 380kv/132kv/110kv/13.8kv at ALSTOM FACTORY,Saudi Arabia.

OVERSEAS EXPERIENCE: (Period: Feb-2014 to June-2014)

Projects Executing in jubail,Saudi Arabia.

Commissioning of all Electrical Eqiupments in 34.5/4.16KV at Saudi Aramco Total Rifinary Oil project, SATROP, Jubail, Saudi Arabia.

Nature of the job : Testing & commissioning of 34.5/4.16kV,25MVA Transformers, 4.16/0.480kV transformers,HT motors, LT motors, INCLUDING SWITCHGEAR PANELS.

Report to Lead commissioning Engineer for Pre Comm and Commissioning of all electrical systems associated with SATROP Plant.

Supporting with multi-national vendors & Subcontractors.

Testing and Commissioning of ABB 4.16KV and 415V Switchgear in powerskids.

Responsible for HV Motors Differtential stability & sensitivity checks.

Responsible for solo & load run testing of HV & LV motors.

OVERSEAS EXPERIENCE: (Period: July-2014 to Dec-2014)

Projects Executed in Jubail, Saudi Arabia.

Commissioning of all power Eqiupments in 34.5KV,4.16KV,25MVA Transfomer,0.480KV Substation, Sadara gas supply project,SABIC, Saudi Arabia Gas Industries Corparation, Jubail,Saudi Arabia.

Nature of the job : Testing & commissioning of 34.5/4.16kV Transformers, 4.16/0.480KvTransformers,HT motors, LT motors, INCLUDING SWITCHGEAR PANELS.

Report to Lead commissioning Engineer for Pre Comm and Commissioning of all electrical systems associated with Sabic Gas Plant.

Supporting with multi-national vendors & Subcontractors.

Testing and Commissioning of Hyundai 34.5KV & 4.16 Switchgear, ABB 0.480KV, Switchgear.

Commissioning & Testing of 34.5/4.16KV, 4.16/0.480KV, 34.5/0.480 transformers, RTCC and AVR panel.

Responsible for solo and load run testing of HV & LV motor and comperssor’s upto 34 MW and integrate it with DCS.

Responsible for doing REF, Stability test, End to End checking, Bus Bar Diff, Transformer Diff, Line Diff, Motor Protection, ATS, MTS function and synchronizing check for switchgear.

Commissioning and startup of Gutor Schneider Electric UPS of 110VDC, 240VAC and 415VAC.

OVERSEAS EXPERIENCE: (Period: Jan-2015 to April 2016)

Projects Executed in Jubail,Saudi Arabia.

Commissioning of all power Eqiupments in 34.5KV,4.16KV,25MVA Transfomer,0.480KV Substation, Saudi Aramco and Dow Chemical project,SADARA, Saudi Aramco, Jubail,Saudi Arabia.

Nature of the job : Testing & commissioning of 34.5/4.16kV,25MVA Transformers, 4.16/0.480KvTransformers,HT motors, LT motors, INCLUDING SWITCHGEAR PANELS.

Report to Lead commissioning Engineer for Pre Comm and Commissioning of all electrical systems associated with Sabic Gas Plant.

Supporting with multi-national vendors & Subcontractors.

Testing and Commissioning of Hyundai 34.5KV & 4.16 Switchgear, ABB 0.480KV, Switchgear.

Commissioning & Testing of 34.5/4.16KV, 4.16/0.480KV, 34.5/0.480 transformers, RTCC and AVR panel.

Responsible for solo and load run testing of HV & LV motor and comperssor’s upto 34 MW and integrate it with DCS.

Responsible for doing REF, Stability test, End to End checking, Bus Bar Diff, Transformer Diff, Line Diff, Motor Protection, ATS, MTS function and synchronizing check for switchgear.

Commissioning and startup of Gutor Schneider Electric UPS of 110VDC, 240VAC and 415VAC.

Activies Carried out with SADARA Engineers.

Measurement of TRAFO. IR value.

2Kv test on core & clamp structure.

Measurement of Ratio & Vector group test.

Measurement of Magnetizing current.

Measurement of Winding resistance.

Measurement of Short circuit impedance.

Measurement of Tan delta and Capacitance of Windings.

Measurement of Tan delta and Capacitance of Bushings.

Calibration of Temp. Indicators.

Hot spot Gradient check of Winding Temperature indicators.

Ratio check of CTs for winding temperature indicators.

On load Tap changer- Operation checks.

Tap position indication check.

Insulation resistance check of devices.

Protective device wiring/operation check.

Fan Motor check.

Operation check of cooling equipments.

Checks on AVR .

Tap changer & cooler alarms / indications check & Tap Changer Parallel operation checks.

Frequency response analysier.

PROJECTS HANDLED IN INDIA

1) Name of the Project : 400/220/6.6 KV S/S & 6.6 KV SWGR

Customer : PGCIL,TALEGAON, PUNE

Client : ABB LTD

Nature of the job : Testing and commissioning of 315 MVA

Transformer &6.6 KV/0.433 KV

SWGR INCLUDING TRANSFORMER

2) Name of the Project : 11/6.6/0.433 KV

SWGR INCLUDING TRANSFORMER

Customer : LNG PETRONET,COCHIN,KERALA.

Client : ABB LTD

Nature of the job : Testing and commissioning of Switchgears and 6 transformers (6*2MVA) .

3) Name of the Project : 6.6/0.433 KV SUBSTATION,

Customer : SAIL,ROURKELA,ODISSA.

Client : VOLTAS LTD

Nature of the job : Testing and commissioning of

Switchgear and 3 transformers

(2*2MVA,1MVA)

and 2 numbers of 11/0.433 KV transformers,

INCLUDING SWGR PANELS.

4) Name of the Project : 132/11/0.433 KV SS

3*10MW BIO MASS

Customer : MVNL,WARDHA, MAHARASTRA.

Client : GET LTD

Nature of the job : Testing and commissioning of 11/0.433 KV

SWGR and 12MVA TRANSFORMER.

5) Name of the Project : 6.6/0.433KV SWITCHGEAR

Customer : HINDALCO LTD,HIRAKUT,ODISSA.

Client : ABB LTD

Nature of the job : Testing and commissioning of Switch gear

including 12 MVA Transformer.

6) Name of the Project : 6.6/0.433KV SWITCHGEAR

Customer : CINDA ENGINEERING LTD

Client : ABB LTD

Nature of the job : Testing and commissioning of 6.6/0.433 KV

SWGR and 3MVA Transformers.

SKILLS SUMMARY

Excellent communication skills - Contacting various user groups, discussing project requirements, Finalising project plans, Development, discussing test plans with QA teams.

Familiarity with industry standard modelling techniques

knowledge in many Windows products likes MS-Word, Power Point, Excel etc

PERSONAL DETAILS

Name : Manonidhi.P

Date Of Birth : 08th Dec 1987

Marital Status : Single

Nationality : Indian

Address : 99,Kovil street,

Anumandai kuppam,

Tindivanam taluk,

Villupuram,

Tamil nadu.

India-604303.

Passport Number : H4935285

Date of issue : 28/01/2009

Date of Expiry : 27/01/2019