Post Job Free
Sign in

Power Plant Electrical

Location:
Plattsburgh, NY, 12901
Posted:
April 27, 2013

Contact this candidate

Resume:

**/**/**

Dear Hiring Manager:

I was interested to see your posting for a job reference number NY1013104

and would like to learn more about this opportunity.

I am a navy nuclear operator with extensive experience as a shut reactor

operator for the US Navy. I have 6 years of experience as a shutdown

reactor operator I monitored and controlled all aspects of the nuclear

power plant parameters. In this role, I was the supervisory element over

all plant operators. I also have 2+ years of experience as a GE field

service engineer. In this role, I was responsible of operations, maintaince

and corresponding with the customers of GE.

I feel that my skills as an operator, a supervisor, and customer relations

would be an asset in this role.

Thank you for your time and consideration. I hope to have the opportunity

to discuss any openings with you in person.

Sincerely

Matthew Smithey

PRESENTED BY;

Matthew F Smithey

home: 518-***-****

*********@*****.***

376 Maragret St. Apt C24

Plattsburgh NY, 12901

Summary: Displayed increasing levels of responsibility and leadership

over six years of Naval nuclear power, including supervision, planning and

performance of electrical systems preventative and corrective maintenance,

as well as safe and responsible watch standing in a nuclear power plant.

Employment: Assist PLC Programmer troubleshooter 05/01/2012 to present

. Design and build electrical circuits various operations of plant

machinary

. Assist Primary programmer in designing skada monitoring system

for plant systems

. Trouble shoot PLC Programming issues and correct them

. Trouble shoot electrical/mechanical issues that plant maintaince

team is unable to solve

. Manage, build, and repair plant Ethernet and DH+ network

. Investigate material issues and propose solutions to plant

engineer

. Correct on site I.T. issues on plant computers and network

. Write develop plant isolation procedures for lock/tagout system

. Program/troubleshoot/repair plant drives

. Test and develop new plant projects that are designed to reduce

cost, increase quality and quantity of production

Employment: Nuclear Power Plant Maintenance Supervisor/Nuclear Trained

Electricians Mate - 07/02 to 07/08

. Performed, supervised and trained junior personnel on the performance

of preventative and corrective maintenance on dc motors and

controllers, ac motors and controllers, PLC's, atmosphere control

equipment, steam driven turbines, emergency diesel generator, AC/DC

and AC/AC variable frequency motor generator sets, alarm and

indicating systems, and AC/DC high voltage rectifier sets.

. Procured and inventoried parts involved in the emergency repair of

electronic and mechanical systems.

. Researched requirements for retesting of numerous repaired

components, assuring adequate and comprehensive testing of systems

affecting reactor safety.

. Served as Electrical Division primary plant maintenance planer from

January 2006 to April 2007, successfully leading the division in all

maintenance items, test procedures, and normal daily operations

. Electrical Operator, Shutdown Reactor Operator, and Throttleman

. Safely operated, monitored and supervised operation of nuclear

propulsion plant and all supporting equipment including

instrumentation and control, electrical power generation and

distribution, steam driven turbines, and fluid and steam piping

systems. Directly responsible for reactor core integrity during

dynamic and static plant conditions while shutdown.

. Scheduled and implemented training for Electrical Division and

trained junior personnel on fundamentals of watch standing,

electrical theory, as well as in-depth system knowledge.

. Coordinated over 300 maintenance items including pre and post job

testing, data collection, and testing procedures.

. Coordinated the calibration of over 1200 pieces of equipment

including pressure and temperature gages, electrical meters,

electrical test equipment, and special calibration tools.

. Severed as ships force representative in the ship deficiency

committee

. Represented the command during board meetings with all the ship yard

representatives and discussed production issues and ways to correct

them

. Discussed production requirements and assigned work to either the

correct shop or to ship's force

Employment: Field service engineer - (10-08-to 01-11)

. Performed, and lead troubleshooting/maintaince/mod changes on

electrical and mechanical systems (hydrolytic brakes/valves, gear

boxes, Ac/DC motors/generators, operated/maintained IGBT converters,

PLC's, blade/yaw bearings and slew rings)

. Work with cranes and rigging to perform gear box and generator change

out and work with hub crane to switch out pitch drives

. Reprogrammed/trouble shoot PLC's when software or unit malfunction

. Wrote service reports and time sheets on an internet based software

program

. Performed EHS safety inspections and lead EHS meeting as the site's

lead EHS representative to ensure the teams been properly educated on

safety requirements

. Performed trend analysis using computer based software linked to a

fluke multi-meter for variations in current for operating motors

. Reprogrammed/tested/replaced control cards for an IGBT converter

Education:

Naval Nuclear Prototype,

Received hands-on training dealing with the safe operation of a nuclear

power plant as a Reactor Operator.

Naval Nuclear Power School,

Received classroom training on instrumentation and control, higher math,

heat transfer and fluid flow, physics, chemistry, radiation protection,

advanced electronic, mechanical and electrical systems and reactor

principles.

Nuclear Field Electricians Mate "A" School,

Educated on basic electrical theory, electronics fundamentals,

communication devices, digital logic, solid state devices and ac and dc

motors with a major emphasis on system troubleshooting.

1.5 MW WTG tech School

Educated on the operation of mechanical and electrical components within a

Wind turbine generator

Received hands on training on trouble shooting various mechanical and

electrical trouble shooting and maintenance procedures

Educated on all EHS requirements regarding wind turbine operations and work

practices

Salem/GE pitch School

Educated on the operation of the new style pitch system and the software

based diagnostic system

GE Frequency Converter School

Learn the theory, operations, and repair/maintaince required for an IGBT

controlled frequency convertor



Contact this candidate