Post Job Free
Sign in

Engineer Technician

Location:
Bangalore, KA, 560100, India
Salary:
35000
Posted:
March 26, 2013

Contact this candidate

Resume:

CURRICULUM VITAE

JAYENDRA.S.B

S/O BOREGOWDA

SHAMBUNAHALLI,

MELKOTE (H), PANDAVAPURA (T),

MANDYA (D).

MOBILE:+919*********

CAREER OBJECTIVE:

To attain a challenging and responsible position. Where I can contribute to

the best of my skill and efforts for the growth of the company as well as myself.

EDUCATION SUMMARY:

SL no Course Institute Result

1 S.S.L.C Jakanahalli govt High school 50%

2 2 puc Govt puc collage pandavapura 53%

COMPUTER KNOWLEDGE:

Basic and Internet browsing. Hard ware net working .trouble shooting .system os&softwer

installation &maintaincs .virus scanning.very good knowledge of .excel .ms office. Ms word

photo shope.

W

ORKING EXPERIENCE

1.NAME OF the Company .NR SWITCH N RADIO SERVICES Banglore

from.03.02.2008 to 03.05.2008.Trainee 3Months

from. 10.05.2008 to still

Designation : telecommunication.Technician. rigger

Indoor Work

• BTS Installation as per layout plan.

• Battery Bank installation, interconnection & cabling of BTS.

• Rectifier Rack/ SMPS installation.

• PCM routing and kroning, alarm cable routine.

• ECB, IGB, EMP installation & earthing.

• FEP cutting, finishing, sealing, jumper routine, connectorisation and termination.

• Indoor cable tray installation.

Labeling of all the cables and jumpers as per customer standard.

Outdoor Work

Horizontal cable tray fitting, pendulum support installation and grouting.

• Antenna fixtures installation.

• Antenna installation & alignment.

• Feeder routine, Earthing, weather proofing & labeling

All work is to be carried out as per drawing.

The following activities has to be carried out for one Hop I. e. at two different sites to make

one link-

• Microwave Rack installation

• Minilink installation & Commissioning of FIU/RRI/EITI

• Antenna installation & IF Cable routine

• DC connection to minilink through DCDB / MCB

• Earthing of Rack, IF as per site engineer instruction

Alignment of Microwave to achieve required level

I working in Nr switch n radio services

1.Nokia seimens Bts installation as working in Karnataka, tatadocomo equipment.

2.Bts installation as working in karanataka.huwaei .projects. .bsnl.2g&3g. aircel.2g&3g

3.VSWR testing bird&Anritsu.site master using Power Calibration using bird site analyzer & power

tester.

4.Motorola bts &Nortel bts .swap site installation in karanataka

5. M/W installation and alignment for 0.6MW,1.2MW,1.8MW. Knowledge of BTS, MW &

GSM,antenna alignment etc

6. Checking of feeder cables, high Jumpers, Antenna, Antenna Tilt (Mech & Electrical), Antenna

Height, TMA or CDU

7.Change Antenna Heights, azimuth and Tilt as per Instruction given by RF Engineer.

8. Installation of feeder cable, High Jumpers, antenna, TMA, CDU.

9. Change of antenna Height and location.

10. Cable Tracing from antenna end to BTS end.

11. Checking the swapping of cables.

12.. Making of RF Connector and Jumper.

13. VSWR Measurement

14. Would perform Line-Of-Sight (LOS) Surveys, Microwave Radio Link Optimization,

Microwave Radio Installation & Commissioning and other related activities.

15.Must be able to climb towers and work under pressure.

16. Should be able to Commission Microwave Links.

17. Should be able to Configure & Trouble-shoot Licensed and Unlicensed Frequency Radios.

18. Must be proficient in the use of Compass, GPS, Range Finder etc.

19. Hardware Installation, Microwave Radio Installation, Microwave link Optimization, Surveys.

20. Should be able to install, commission and rectify aviation lamps.

21. Should be able to install, commission and rectify lightning arrester continuity & earthing.

22. Should be able to carry out minor civil works like pole fixing on roof top sites for

GSM/microwave antennas.

23. Hands on experience in installation of internal/external cable ladders and cable routing.

24. Should be able to install and commission roxtec.

25. Should have the knowledge on security measures to be carried out during tower climbing.

26. Should be able to install/remove/re fix antenna mounting poles (gsm/mw).

27. Preparing the BT 3002 cable from DDF to M/W equipment with T 43 Plug at DDF end and

BNC Male Connector at M/W equipment.

28.Pix Alarm wiring to be done with termination of alarm points on the krone DDF.

29. Termination & Testing of all external alarms on the Krone DDF

30.Call & Sector swapping testing using Net Monitor Software by cell phone.

31. BTS/BSC/MSC Installation and commissioning, RF Survey/RF Planning. Service

technician, Drive Test, Switch .technician

RBS INSTALLATION

2G / 3G Ericsson experience, ideally

RBS2954, RBS2964, RBS2111

RBS6601E, RBS6601, RBS6202

Mini-link / Microwave

Installation and Commissioning

PERSONAL DETAILS

Name - JAYENDRA.S.B

Father name - BOREGOWDA

Nationality – Indian

Gender –Male.

Marital status – Single.

Date of birth – 03.04.1988

Language known Kannada.English .Tamil. Hindi.Telugu

E-mail ID – **********@*****.***

Contact No. –+919*********

Address . local - JAYENDRA.S.B

NO.163.H S R LAYOUT 4 TH SECTOR

NEAR BDA COMPLEX

BANGALORE

MOBILE:+919*********

DECLARATION

I have by declared that the details furnished above are true to best of my knowledge.

Pl ace: (SIGNATURE)

Date



Contact this candidate