Post Job Free
Sign in

Power Plant Engineer

Location:
Visakhapatnam, AP, 530016, India
Posted:
April 05, 2013

Contact this candidate

Resume:

CURRICULUM VITAE

OF

VIKRAM.KOKA

Email: abq0j9@r.postjobfree.com

Mob: 91-901*******

Nationality: INDIAN

Date of Birth: 05 Jan 1983

Designation: Q.C. INSPECTOR

Total Work Experience: 5 Years

PROFESSIONAL PROFILE:

SUMMARY OF EXPERIENCE:

> Having 5 years of experience in field of Structurals, Piping, Storage

Tanks, Static Equipment & Castings.

Education Qualification : B.Tech in Mechanical Engineering

Technical Qualification : NDT LEVEL II (PT, MPT, RT, UT)

Computer Skills : AUTO CAD & MS

Office

Details of experience:

Organization : LLOYDS REGISTER ASIA ( UNDER

CONTRACT BASIS)

Designation : Q.C.INSPECTOR (THIRD PARTY).

Duration : DEC 2011 till date

> Vendor Inspections Performed:

Client : BHARAT HEAVY

ELECTRICALS LIMITED (BHEL)

Projects involved

. NTPC Tapra Power Plant

. Elena Power-Nasik

. Elena Power -Amaravathi

. Tishreen Power Plant -Syria

. SPL Surana Power-II

. MatriShri Usha Jaiswal Mega Power Plant

. Haldia Power Plant

. Maruti Suzuki 70MW Power Plant

. ONGC OPAL DAHEJ-II

Description: Fabrication of Deaerator Storage Tanks, Deaerator Heaters,

High pressure heaters, Low pressure heaters for Thermal Power Plants.

Activities performed:

. Material identification as per QAP and review of Material Test

Certificates.

. Longitudinal/circumferential weld joint fit-up examination as per

relevant drawings and checking orientation of seam on shell

course and joint alignment.

. Witnessing welder qualification tests.

. Review of W.P.S & P.Q.R

. Witnessing back chipping / gauzing with penetrant test to ensure

defect free welds.

. Witnessing nozzle fit-up examination to check elevation, tilit,

projection as per relevant code, drawings & QAP.

. Heads forming inspection as per relevant drawing, code and QAP.

. Ensuring welding is carried out as per relevant weld detail drawing

and WPS.

. Ensuring weld sizes as per relevant weld details in the drawing.

. Witnessing mechanical tests in laboratories as per supplementary

requirements.

. Reviewing NDT reports, pressure test reports, surface

cleaning/painting reports.

. Reviewing Post Weld Heat treatment / normalizing charts as per QAP,

Drawings and code.

. Final dimensional inspection of pressure vessels as per relevant

latest revised drawings and witnessing final NDE tests (Penetrant

Test, Magnetic particle test, RT, UT).

. Review of Radiographic Films evaluation and interpretation.

. Preparing final inspection release note after complete fabrication

before dispatch.

Client : BOC INDIA LTD,

KOLKATA

Projects involved : MRPL Phase-III Poly

Propylene complex (MRPL)

HPCL,

Visakhapatnam

Meramandali,

Orissa

Description : 50 KL Liquid Nitrogen

Storage Tank

75 KL Liquid

Nitrogen Storage Tank

30 KL Liquid

Nitrogen Storage Tank

Activities Performed :

. Material identification as per QAP and review of Material Test

Certificates.

. Longitudinal/circumferential weld joint fit-up examination as per

relevant drawings and checking orientation of seam on shell

course and joint alignment.

. Witnessing welder qualification tests.

. Review of W.P.S & P.Q.R

. Witnessing back chipping / gauzing with penetrant test to ensure

defect free welds.

. Witnessing nozzle fit-up examination to check elevation, tilit,

projection as per relevant code, drawings & QAP.

. Heads forming inspection as per relevant drawing, code and QAP.

. Ensuring welding is carried out as per relevant weld detail drawing

and WPS.

. Ensuring weld sizes as per relevant weld details in the drawing.

. Witnessing mechanical tests in laboratories as per supplementary

requirements.

. Reviewing NDT reports,, pressure test reports, surface

cleaning/painting reports.

. Reviewing Post Weld Heat treatment / normalizing charts as per QAP,

Drawings and code.

. Final dimensional inspection of pressure vessels as per relevant

latest revised drawings and witnessing final NDE tests (Penetrant

Test, Magnetic particle test, RT, UT).

. Review of Radiographic Films evaluation and interpretation.

. Issuing Inspection release note.

Client: Coromandel International Limited, Visakhapatnam

Project: Ammonia Pipe Line Decommissioning and Recommissioning

Code of fabrication: ASME B31.3

Activities performed:

. Material Identification with their test certificates for compliance

with relevant specification and drawing requirement.

. Ensuring that relevant WPS, PQR, WPQ are in accordance with

stipulated code requirements.

. Witnessing D.P.T on surface area of all inch valves weld joints

during renewal and blinding.

. Witnessing D.P.T examination on entire surface area of anchor

support plate to pipe fillet weld joints.

. Witnessing D.P.T. on entire surface area for 3 inch line

replacement portion weld joints.

. Reviewing R.T. films for the butt joints.

. Witnessing Pneumatic test for both the 3inch lines.

CASTING EXPERIENCE:

Client: Indian Oil Corporation Ltd, Panipat,

Thermax Ltd, Pune,

Relaince Industries Ltd.

Supplier: Hastalloy India Ltd, Anakapalle, Visakhapatnam.

Projects involved: IOCL Panipat Refinery Plant 9060,

PG0513 GGSR, Bhatinda,

PTA-5, PTA-6 & PVCVCM DBN Project, Dahej.

Description: Inspected Refinery castings such as Ladder side members,

Intermediate

Tube sheets support brackets, cast pin and pink

keepers.

Activities performed:

Scope of inspection as per QAP

Identifying test bars with surveyor hard punch

Reviewing Chemical composition of the material for compliance against the

material specification.

Witnessing mechanical testing and reviewing results

Carrying out visual and dimensional inspection

Witnessing DPT for the offered quantity

Reviewing radiographs

Witnessing Positive metal Identification (PMI) for castings

Organization : SREE THANDAVA LAKSHMI ENGG.

WORKS

Designation : QA/QC ENGINEER

Duration : Nov 2009 to Dec 2011

> Worked as QA/QC Engineer for Static Equipment and Structural

. fit up, weld visual

. Qualification of welders

. Coordinating with welders & fitters time to time.

. Preparing Material flow chart as per drawing.

. Offering job to third party inspectors.

. Witnessing NDT tests and coordinating with NDT consultants.

. Ensuring all radiography is performed for butt joints as per

drawing.

. Preparing all documents such as log sheets, stage inspection

reports, Final dimensional reports material flow charts, N.DT

consolidated reports etc.

. To check all material certificates are endorsed with material flow

charts or not.

. Finally contacting Third party inspector for issuance of

Inspection release note.

Organization : SRUJANA ENGINEERING WORKS,

VISAKHAPATNAM

Designation : SITE ENGINEER

Duration : MAY 2008 to OCT 2009

Worked as QA/QC Engineer for Static Equipment and Structural

. fit up, weld visual

. Qualification of welders

. Coordinating with welders & fitters time to time.

. Preparing Material flow chart as per drawing.

. Offering job to third party inspectors.

. Witnessing NDT tests and coordinating with NDT consultants.

. Ensuring all radiography is performed for butt joints as per drawing.

. Preparing all documents such as log sheets, stage inspection reports,

Final dimensional reports material flow charts, N.DT consolidated reports

etc.

. To check all material certificates are endorsed with material flow

charts or not.

. Finally contacting Third party inspector for issuance of Inspection

release note.

Personal Information:

Name : VIKRAM KOKA

Father's Name : K.N.K.KUMAR

Gender : Male

Marital Status : Single

Languages Known : English, Hindi, Telugu & Tamil.

Date of Birth : 05-01-1983

Pass port number : E 6756990 Valid upto Nov 2013

Permanent Address : S/o. K.N.K.Kumar,

Drno.45-49-14/2,

Flatno.502, Siddhi enclave,

Abidnagar,

Visakhapatnam-530016

Andhra Pradesh, India

DECLARATION

I swear that the details furnished above are true to the best of my

knowledge and i will discharge my duties to the entire satisfaction to my

superiors and to the organization.

(Vikram.K)



Contact this candidate