Bob Landini Project Commissioning/Validation/QA Manager

Multi discipline manager of construction projects /contract administration/supervision. Experience specializing in the development, implementation, and execution of construction schedules/projects for aggressive Fast Track projects. Experience in: process equipment & systems, clean water, steam, Pharmacieutcal gasses, high purity piping/Air/HVAC systems modular process equipment Building Automation Systems (BAS) and Process Automation. Commisioning of process equipment, cooling towers, chillers, and qualified and non qualified utilities. Performed vendor surveillance, Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) activities for process equipment Managed commissioning, start up and validation efforts for clients on High Purity/Aseptic equipment, piping and HVAC systems, including commissioning/start-up and trouble shooting of systems. Have administered contracts for instalation of high purity piping, power piping, process piping and process equipment and have managed commissioning and qualification contracts. Experience in Fossil and Nuclear power facilities, petrochem facilities and pharmacieutical facilities.

Currently employed by Parsons Infrastructure & Technology, July 2007 to present

Department of Energy Savanna River Salt Waste Processing Facility

Technical Representative overseeing fabrication of large and small ASME vessels for the nuclear waste processing facility being fabricated in York, PA and at the Navy Shipyards in Philadelphia, PA. Engineering coordinator and onsite QA surviellances for fabrication to NQA-1 and ASME Section VIII.

MedImmune FMC facility, Frederic MD.

Process piping coordinator on a 600 million dollar new biotech facility. Administered high purity piping contractor on installation of ~65,000 LF of high purity piping and process equipment. Main client interface on quality issues on all validated systems and commissioned systems. Supervised contractor flushing, testing and passivation. Managed commissioning and qualification activities on high purity process systems

Previous Experience:

Washington Group International, Inc.

Pfizer Convinia Transfer Project, Kalamazoo, MI 3/2006 to Aug 2007

Commissioning and Qualification (C & Q) Manager as Pfizer representative for animal health antibiotic sterile formulation and aseptic filling product transfer project. Transferred freeze dryer, filler, capper and Clean Steam Generator with new Autoclave, Cabinet Washer and HVAC equipment using new Commissioning & Qualification (C & Q) process based on ISPE Base Line Guides process. Performed Gap Analysis evaluation on transferred equipment for compliance with current commissioning and qualification requirements. Commissioned and qualified new qualified Water For Injection (WFI), clean steam and Pharmaceutical grade gasses (Air & N2).

Amgen Waste Water Project, Juncos Puerto Rico 9/2005 to 3/2006

Mechanical Coordinator/Superintendant for the construction of a waste water treatment plant mechanical completion team. Perform system flushes/commissioning and expedite testing and closure of punch list items.

Pfizer Gelfoam Upgrade Project, Kalamazoo, MI 7/2004 to 9/2005

Project Validation Manager for class III medical device upgrade project providing functional and administrative management of all project validation activities. Included 2 new sterilization ovens and new qualified HVAC/Utilities. Re-qualified existing/relocated/modified process equipment. Commissioned and qualified new purified water piping Pharm gasses (Air & N2). Managed, developed and implemented commissioning/validation test procedures to ensure compliance with appropriate regulatory, validation, company standards and best industry practices. Developed a new commissioning plan in accordance with ISPE Base Line Guides for client.

Suitt Construction Co., Manassas, VA 1/2004 to 6/2004

Eli Lilly Insulin Facility, Manassas, VA (Project cancelled)

Project QA Manager for a grass roots 600 million dollar insulin manufacturing facility. Responsible for overall project construction quality plan and coordination of commissioning activities as construction manager. Developed site specific Quality Plan for project and set up quality and commissioning program for management of Contractors quality control programs. Perform project review of all specifications and drawings prior to award of contracts and purchase orders for incorporation of quality/commissioning requirements. Coordinated all discipline review comments back to design engineers and client

Lockwood Greene Engineers /J. A. Jones Construction Co., 1989 - 2004

Lockwood Greene Engineers /J. A. Jones Construction Co., Charlotte, NC

Merck & Co., Danville, PA., Project Validation Manager, $80M Pharmaceutical Expansion" Project Validation Manager for a new antibiotic bulk chemical manufacturing facility, new quality control laboratories, and a new/up-graded Plant Wide DI Water System. Extensive high purity piping installation and qualification. Supervised writing and implementing IQ/OQ Protocols. Developed/managed tracking system for TOPs & ETOPs

Merck & Co., Rahway, NJ, Factory 31, Cox 2 Phase 1 & 2, Factory 12 Refurbishment, Brine Chiller " Project QA/Validation Manager for the expansion of a 50-year old operating bulk chemical manufacturing facility. Responsibilities included implementation of the projects quality program, developing and implementing validation protocols for project equipment and qualified process and utility high purity piping. Supervised Installation Qualification (IQ) implementation. Developed/managed tracking system for TOPs & ETOPs

Merck & Co., Flint River Facility (Albany, GA) " Project QA/Validation Manager for Construction Manager performing expansion of existing bulk pharmaceutical manufacturing facility. Responsible for the establishment and implementation of the project quality/validation/commissioning program. Duties also included developing and implementing validation/commissioning protocols for client equipment and supervising implementation of Installation Qualification (IQ) Protocols for the installation of new equipment and process piping systems. Performed training of contractor orbital welding and inspection personnel for high purity piping systems. Participated in Lessons Learned programs on all Merck projects

Southern Electric International, Sealston, VA, Birchwood Power Plant

Project QA Manager for 240 MW Pulverized Coal Cogeneration Facility with a CE/ABB boiler and General Electric steam turbine

Schering Plough, Kenilworth, NJ, Manufacturing Upgrade Project

Project QA Manager, Commissioning and Qualification Manager for Construction Manager on expansion of existing pharmaceutical manufacturing facility. Responsible for the establishment and implementation of the project quality/commissioning and validation program. Implemented IQ/OQ Protocols for the installation of new equipment, purified water USP system, clean in place (CIP) system, quality control laboratories, process control system (PLC), and HEPA filter systems. Performed vendor surveillance, FAT, and SAT activities for this project

B.P. Oil Alliance Refinery, Belle Chasse, LA, Merox Project Refinery Expansion " the first B.P. project in North America to implement the new B.P. Refinery Practices and B.P. Guidelines for Site Construction.

Cogentrix Cogeneration, Richmond, VA,

Project QA Manager for a 220 MW Coal Fired Cogeneration Facility. Eight CE/ABB stoker fired boilers with four GE turbine generators also providing process steam to DuPont, installed in accordance with Duke Fluor/Daniel Design. This project was the first stoker-fired plant to meet and exceed

EBASCO Services, Comanche Peak Nuclear Station (Twin 1150 MW PWR) 1981-1989

Quality Assurance Lead, ANSI N45.2 Level II inspector on electrical raceway, welding, civil, structural. Performed electrical raceway inspections in accordance with S910 engineering guide, requiring calculation of loads, spans, separation spacing and weights to approve electrical raceway installations. Trained inspectors providing OJT. Level II in UT.

Bechtel Nuclear Fuels Organization, Hanford Washington, FFTF/FMEF 1978-1981

Site Quality Assurance Manager at DOE experimental Fast Flux Test Facility project managing mechanical and electrical inspection program.

Testing Engineers Inc. Oakland, CA, 1976-1978

Registered Construction Inspector state of California. Project inspector on several projects in Bay area managing civil, structural, NDE and soils inspections. Largest project Embarcadero Center, San Francisco. AWS CWI, Level II concrete, soils NDE (MT, PT, UT)

AMSCO Corp, Chicago Heights, Ill 1971-1976

Metallurgical Quality Assurance Technician. Performed QA testing of all specialty welding products. Level II in RT, MT, UT, PT methods. Performed welding and analytical testing (hardness, usability, spectrographic). Analyzed and responded to customer complaints.

Education:

Florida Institute of Technology

On Line Computer Technology Microsoft Office series

Prairie State University

Chicago Heights, Ill

Mechanical Technology

Contra Costa College

San Pablo, CA

NDE/PT/MT/UT/ET/RT methods

Certifications:

American Welding Society Certified Welding Inspector (CWI), not current

ASNT Level III in MT, RT & PT test methods,not current

ANSI N45.2 Level II Mechanical & Electrical Inspector,not current

Registered Construction inspector in state of Califonia, not current

Training:

OSHA 30 hour, ISPE - C & Q Guidelines and Practices