Post Job Free
Sign in

Quality Control Medical

Location:
Valladolid, Western Visayas, 6103, Philippines
Posted:
March 13, 2013

Contact this candidate

Resume:

REX A.GATILOGO,JR.,RMT,MT(ASCPi)

Tabao Proper, Valladolid,

Negros Occidental, Philippines, 6103

Mobile number: +639*********

+639*********

E-mail address: ***********@*****.***

OBJECTIVE: To practice my profession as Medical Technologist in a dynamic

working environment where my knowledge, potential and experiences will be valued

and recognized, my talents and skills honed and explored.

AREAS OF EXPERTISE:

Medical Technologist- Generalist

PROFESSIONAL QUALIFICATIONS:

EDUCATION:

BSMT School: University of Negros Occidental -Recoletos

#51 Lizares Avenue, Bacolod City,

Negros Occidental, Philippines, 6100

Contact number: +633*-******* and +633*-*******

Year Graduated: March 19, 2003

PROFESSIONAL LICENSE:

Type of License: Clinical Laboratory Technologist

In The State Of New York

Country of Issuance: United States of America

Date of Issued: September 17, 2012

Expiration Date: August 31, 2015

Type of License: American Society of Clinical Pathology (ASCPi)

International Medical Technologist

Country of Issuance: United States of America

Date of Issued: March 27, 2008

Expiration Date: No expiration Date

Type of License: Registered Medical Technologist

Country of Issuance: Philippines

Date of Issued: October 16, 2003

Expiration Date: February 7, 2014

TRAININGS AND SEMINARS ATTENDED:

• “The Philippine Society for Microbiology and Infectious Diseases-Western

Visayas Chapter (PSMID).“8th MID-YEAR CONVENTION ON INFECTIOUS DISEASE

CHALLENGE AMIDST GLOBAL CRISIS”

• “Laboratory Management and Updates in the Practice of Clinical Laboratory

Science” and “Quality Control in Microbiology Laboratory”

• “Revisiting our Legal Responsibilities in the Practice of Medical

Technology: AO-2007-0001 and AO 2007-0027”

• “HUMAN PAPILLOMA VIRUS: ESSENTIAL FOR LABORATORY PROFESSIONALS”

• “PHLEBOTOMY ISSUE AT THE POINT OF CARE”

• “COAGULATION TESTS AND RELATED DISORDERS”

• “HEPATITIS B- THE PHILIPPINE SCENARIO IN 2007”

• “BIRD FLU: A LABORATORIAN’S PERSPECTIVE”

• THE PHILIPPINE ASSOCIATION OF MEDICAL TECHNOLOGISTS, INC. (PAMET) 11th PAMET

NATIONAL MID- YEAR CONVENTION:

“FREEING THE MIND: BREAKING BARRIERS OF CHANGE FOR A GLOBALLY COMPETITIVE

MEDICAL TECHNOLOGY PRACTICE”.

• “SYSMEX PRE-CONVENTION SEMINAR”

• “FOOD AND WATERBORNE PARASITOSIS IN THE PHILIPPINES”

• “THE SIGNIFICANCE OF LABORATORY TEST IN THE MANAGEMENT OF INFECTIOUS

DISEASES

EMPLOYMENT HISTORY:

EMPLOTER 1: TopHealth Medical Clinics, Inc.

G/F South Wing, SM City Bacolod, Rizal Street,

Reclamation Area, Bacolod City,

Negros Occidental, Philippines, 6100

Contact Number: +633*-***-****

Unit/Area: Laboratory Department

Date of Employment: August 19,2011 to September 15,2012

EMPLOYER 2: Bacolod Our Lady of Mercy Specialty Hospital

Eroreco, Mandalagan, Bacolod City,

Negros Occidental, Philippines, 6100

Contact number: +633*-***-****

Total Bed Capacity: 200

Unit/Area: Laboratory Department

Date of Employment: March 16,2004 to January 10,2011

Job Description:

Responsible for collecting blood samples for analysis and observe proper labeling

for each designated test and procedures before submitting the specimen to the

respective section of the laboratory.

Primarily handled the collected specimen properly. And independently resolve

technical specimen issues in the preparation for analysis and specimen storage.

Performs and release accurate results in each clinical laboratory testing in

accordance with established written standard operating procedures accurately and

in timely manner.

Able to operate fully automated machines at the same time maintaining, checking

and ensuring the stability of the machines in order to operate within its optimum

performance before placing it into service.

Performs basic instrumentation and equipment troubleshooting.

Encoding and recording of every laboratory test performed including conducting

monthly census in the number of test done from different sections of the

laboratory.

Performs inventory and checking of supplies, reagents, equipment, chemical

stability and specimen storage in order to ensure the validity of test results and

makes request when necessary.

Maintains the safety guidelines within the different section area of the

laboratory including sanitary measures to the working area, proper disposal of

biohazard substances and proper machine handling.

Participates external quality assurance scheme.

Assigned as a rotating Medical Technologist to different sections of the

laboratory such as Bacteriology Hematology, Clinical Chemistry, Clinical

Microscopy and Parasitology, Blood Bank, Serology and Immunology and

Histopathology-except for cutting of tissue blocks.

BACTERIOLOGY:

• Responsible for receiving all specimens for routine culture, for staining and

other procedures with its proper label and identification.

• Do aerobic culture and inoculate the following specimens on the appropriate media

such as Blood, Urine, Stool, Pus and other body fluids (Pleural, Peritoneal,

Cerebrospinal Fluid (CSF), Synovial fluid )Vaginal and Urethral swabs, Throat

swabs and Wound discharges.

• Isolation and Identification of bacteria from cultures specimen by biochemical

testing.

• Do antibiotic susceptibility tests.

• Responsible for the preparations and availability of various broth and agar

culture media.

• Responsible for the maintenance of live control strains of the commonest clinical

pathogens for Bacteriologic Quality Control Programs.

• Performs microscopic identifications of microorganisms through Gram staining, Acid

Fast Bacilli staining, KOH, and India Ink.

• Observing proper safety guidelines and proper disposal of used media and specimen.

Machines Handled and Operated:

• BACTEC 50

• APIZOE (Activated Product Index)20E and 10S

• INCUBATOR:PRECISION THELCO(Model2) and DIGISYSTEM

HEMATOLOGY:

• Registers sample with patient’s information and appropriate laboratory

identification number after determining the samples submitted are appropriate for

the tests required.

• Perform complete blood count and platelet count with accuracy and reliability.

• Examines blood film and read the required parameters and identifying abnormal

cells.

• Perform the following coagulation tests: Prothrombin time(PT),Activated Partial

Thromboplastin Time(APTT), Clot retraction tests, Clotting time and Bleeding time,

Lee and White coagulation tests, Lupus Anticoagulant test screen.

• Perform the routine and other procedure with accuracy and reliability such as

Hemoglobin, Hematocrit, Red cell count(RBC), Leukocyte count(WBC), Platelet count,

Malarial smear preparation, Peripheral blood morphology, Erythrocyte sedimentation

rate(ESR).

• Analyze and Evaluate quality control samples.

• Able to operate and maintain a fully automated cell counting for complete blood

counts.

Machines Handled and Operated:

• ABX Pentra 60 Mindray BC3000

• Micros 60 Hematology Analyzer ERMA Particle Counter PCE210

• Coulter model Act8 Coulter counter model T660

• Cell-DYN 170 ABX Micros

• MICROSCOPE: OLYMPUS CX31 AND OLYMPUS CX21

CLINICAL CHEMISTRY:

• Receiving and proper labeling of specimen and preparing it for specific tests and

procedures.

• Performs quality control before running each test.

• Responsible for storing samples and reagents according to storage temperature.

• Performs routine chemistry tests such as (RBS)Random Blood Sugar, (FBS) Fasting

Blood Sugar, 2HPPBS(2 hours postprandial blood sugar, OGCT(oral glucose challenge

tests), OGTT(oral glucose tolerance tests), HBA1C(Glycosylated hemoglobin).

• Lipid Profile: Triglycerides, Cholesterol, HDL(high density lipoproteins, LDL (low

density lipoproteins),and VLDL(very low density lipoproteins).

• Kidney Function Test: Creatinine, Blood Urea Nitrogen (BUN) and Blood Uric Acid.

• Electrolytes: Sodium, Potassium, Phosphorous, calcium, Magnesium, and Chloride.

• Liver Function Tests: SGOT(AST), SGPT(AST), Bilirubin(Total, Direct and

Indirect),ALP(alkaline Phosphatase),Total Protein, Albumin, Globulin.

• Pancreatic Enzymes: Amylase and Lipase.

• Special Test: T3 (Triiodothyronine), T4(Thyroxine), TSH( Thyroid Stimulating

Hormone), FT3( Free Triiodothyronine),FT4(Free thyroxine), PSA (Prostate Specific

Antigen, CEA (Carcino Embryonic Antigen), AFP(Alpha fetoprotein).

• Performs Troponin I and Troponin T.

• Do random and 24 hour specimen collection for: Urine Creatinine Clearance, Urine

Protein and Urine Electrolytes.

Machines Handled and Operated:

• Vitalab SELECTRATE Microlab 200(Merck)

• Microlab 100(Merck) Stardust FC

• RAL Clima MC 15 Easylte Analyzer (Na+,K+,Cl-)

• KODAK Eacktachem DT60 Analyzer Cobas MIRA

• Ecktachem Vidas Immunochemistry Analyzer( BioMerieux)

• Centrifuge: Smithkline Beecham (Van Guard V6500)

CLINICAL MICROSCOPY AND PARASITOLOGY:

• Performs routine urinalysis and routine stool examination procedures.

• Performs special tests in urine samples like: Bence Jones Protein, Pregnancy

test(serum and urine, Urine Ketones, Urine Micral Test.

• Performs red cell morphology in urine samples as per physician request.

• Performs concentration method in stool specimen and occult blood.

• Do Seminal Fluid Analysis.

• Do Chemical test, Macroscopic and Microscopic examination on Cerebrospinal fluid

(CSF) and other body fluids such as Synovial Fluid, Pericardial Fluid, Peritoneal

Fluid, and Pleural fluid.

• Do 24 hour HCG titer

Machines Handled and Operated: MICROSCOPE: OLYMPUS CX2

BLOOD BANK, SEROLOGY AND IMMUNOLOGY:

• Performs the following tests and pprocedures like:

- Blood Typing and Rhesus (ABO and RH) tests (Forward and Reverse)

- Direct and Indirect Coomb’s tests.

• Performs compatibility testing (Major and Minor Crossmatching).

• Performs autocontrol when there is three successive blood units incompatibility

during compatibility testing.

• Experienced in blood donation collection and screening on blood donors for:

Hemoglobin, Hematocrit, VDRL/RPR, HIV1/2, HCV, HIV, HBsAg, Blood typing, vital

signs, and routine standard questioning for blood donors.

• Performs therapeutic phlebotomy from Polycythemic/Erythremic patients as requested

by attending physician.

• Prepare blood components such as Packed Red Blood Cells (PRBC) and fresh Whole

Blood.

• Performs serological tests and procedures like: C-Reactive protein, ASOT(Anti-

Streptolysin O titer), Widal’s test, Typhidot determination and Rheumatoid factor.

• Performs Hormone assay namely: TSH(Thyroid Stimulating Hormones),

T3(Triiodothronine),T4(Thyroxine), Ft4(Free Thyroxine),FT3(Free Triiodothyronine).

• Performs tumor marker assay such as PSA(Prostate Specific Antigen), CEA(Carcino

Embryonic Antigen) and AFP(Alpha fetoprotein).

Machines Handled and Operated:

• ELECSYS 2010

• MINIVIDAS

• INCUBATOR:MEMERT H20(LO-0578)

• Centrifuge: Analytical Centrifuge

HISTOPATHOLOGY:

• Register specimens with patient’s information. Always observes proper labeling and

identify the patient versus specimen then log it in logbook.

• Receives and fixes specimens for cell block and cytology.

• Responsible for the submitted tissue if it is properly preserve in a fixative

reagent like in 10 percent formalin.

• Assists the Pathologist during gross examination of specimen.

• Processes tissues and prepared slides for microscopic study of Pathologists.

• Do routine H and E staining of tissues and cervico-vaginal smear for microscopic

studies.

• Responsible for keeping working area organized, clean and efficient and storing

slides and tissue blocks orderly in their respective cabinet for future purposes.

PERSONAL INFORMATION:

Date of Birth: February 7, 1982

Birth Place : Bacolod City, Negros occidental,

Philippines

Gender : Male

Marital Status: Single

Citizenship : Filipino

Languages/Dialects spoken: Hiligaynon, Tagalog and English

Contact Person: Delia A. Gatilogo

Address : Tabao Proper, Valladolid

Negros Occidental, Philippines, 6103

Contact number: +639*********

REFERENCES:

Dr. Walter L. Villanueva, MD, DPSP

Pathologist, Laboratory Department

Bacolod Our Lady of Mercy Specialty Hospital

Eroreco, Brgy. Mandalagan, Bacolodo City,

Negros Occidental Philippines,6100

Hospital contact Number: +633*-***-**** Local 120 and 127

Clinical Laboratory number: +633*-***-****

Robert John S. Lamis, RMT, MA, MT (ASCPi)

College Professor, Medical Technology Department,

College of Arts and Sciences

University of Negros Occidental-Recoletos

#51 Lizares Avenue, Bacolod City,

Negros Occidental, Philippines,6100

Contact Number: +633*-***-**** Local:172

Mary Jo V. Aliento, RN

Clinic Supervisor

Tophealth Medical Clinics, Inc.

SM City Bacolod, Bacolod City

Negros Occidental, Philippines,6100

Contact Number: +633*-***-****



Contact this candidate