Post Job Free

Resume

Sign in

NDT/QC Inspector

Location:
San Antonio, TX, 78265
Posted:
February 15, 2013

Contact this candidate

Resume:

Lora L. Cantu

P.O. Box ***** San Antonio, TX. ***65

210-***-****

abodm9@r.postjobfree.com

Employment History

*-**-** /**-**-12 Spherion@Alcoa -Howmet Corporation, Wichita Falls,TX.

Penetrant Level II Inspector

Training: Certificate for 20 hours level II Penetrant class.

Training: Process & Inspecting aircraft components.

Flourescent Penetrant Inspection ASTM 1417/NAS 410

Water Washable Penetrant Type 1 method A & D, sensitivity level 3 & 4,

Form A developer.

Such customers include Solar, Pratt & Whitney, GE, Fiat, Rolls Royce, Pratt

Canada, Snecma, Honeywell.

Indications found are dross, inclusions, shrink, linears, plus metal, cold

shuts, and cracks.

2-9-11/2-24-12 Aerotek Aviation@ Chromalloy Dallas, Farmers Branch TX.

FPI Level II Inspector

Training: Penetrant OJT 1856 hours/ QCP-110 & NAS 410 Certificate

Training: Process & Inspecting aircraft components

Flourescent Penetrant inspection of jet engine parts for detection of open

to the surface discontinuities

in metallic/ non metallic, non porous materials and guideline of ASTM 1417

are being met. Daily checks performed on penetrant line Type 1 method D,

sensitivity level 4, Form A developer prior to any inspections. Parts

inspection on jet engine blades, vane segments, compressor blades, IPC

blade tip,

HPC Variable Vane, BPC blade tip. Customers include Pratt & Whitney, Rolls

Royce, KC-10, GE, IAE, CFMI.

Input data information in computer at this FAA Repair Station EN2R800K.

12-30-10/1-10-11 PQNDT@PCC Structurals, Franklin, New Hampshire

PT Level II Inspector

Training: NAS 410 Certificate

The ability to interpret specifications on castings which are processed

through Water Washable Penetrant method A and Form A developer. To be able

to certify the conformance of the castings

per customers requirements while maintain productivity. Daily system checks

at the beginning of

the shift prior to any inspections.

10-10/12-10 NIC@ Pratt & Whitney (Maine/Connecticut)

PT Level II Technician

Training: Non Destructive Evaluation Certificate and Cast Turbine Airfoil

OJT 248 hours includes

Environment Health & Safety Training Level 2 & 3.

Black light inspections on parts processed thru Flourescent Penetrant

Method A & D. Performed an acceptable system capability test at the

beginning of the shift prior to any inspections. Inspections are done by

part number which have specific standards & codes for that operation. Parts

includes cast

turbine airfoils, vane assy, jet engine blades which have been cast,

machined, welded, and coated.

Input data information in the Solumnia computer system.

08-08/06-10 National Oilwell Varco- Houston,Texas

Quality Control Receiving Inspector/ Quality Control Document Specialist

Training: Penetrant Class Level I & II for 12 hours, Magnetic Particle

Class Level I & II for 20 hours

Conduct Visual and Dimensional inspections for product compliance. Worked

with drawings, verify

quantity of parts received from vendor, material certs, hardness of

material, drawing revision. Wrote non-conformance reports. Utilized digital

calipers, ID Mic, OD Mic, No-go-gages, plug gage, radius gage.

Input data information into the Glovia computer system to clear parts to

stock in warehouse.

Assisted the Document Control Group for missing quality control

documents, such as Material Test Certs, Hydro Test Charts, Weld Maps, NDT

documents, and Data Books. Heavy computer research and

responsible for handling, scanning quality documents for our customers

data books. Established a new

relationship with vendors and middle management.

01-08/06-08 PQNDT@ Metal Tek International- Waukesha, Wisconsin

PT Level II Technician

Training: Penetrant Level II OJT 660 hours,Magnetic Particle Level II OJT

150 hours NAS 410

Training: Detergent & Steam cleaning, Safety procedures, PPE, Respirator

training, Operating equipment such as the hoist for loading and unloading

parts.

Performed a spray to waste electrostatic penetrant line. Performed method A

water washable spray, Flourescent Penetrant dye and red visble dye. Some

our parts include casting, manufactured parts,

manifold tubes, petro chemical tubes. Some our customers are Exxon Oil

Equistar, Midrex, Texas Eastman, CF Industries, GE, Rolls Royce, Boeing,

Chevron Phillips, Petro-Chem, Great Point Energy, etc.

Applicable techniques & specifications, codes, interpretation of

indications. Liquid Penetrant

procedures of ASME Section V and Section VIII Division I.

10-07/12-07 NIC@ Pratt & Whitney (Maine/Connecticut)

PT Level II Technician

Training: Certificate Cast Turbine Airfoil Level II OJT 201 hours

Training : Certificate NDT Record, Environment Health & Safety Training

Level II

Black light inspections on parts processed thru Flourescent Penetrant

method A & D. Performed an

acceptable system capability test at the beginning of the shift prior to

any inspections. Inspections

done by part number which standards & codes for that operation. Parts

include cast turbine airfoil,

vane assy, jet engine blades which have been cast, machined, welded, and

coated. Input data

information in the Solumnia computer system.

07-07/10-07 Dynatech Turbine Services San Antonio, Texas

FPI Level II Technician

Training: Certificate Visual Inspection Level II, FPI Level II NAS 410

Flourescent Penetrant Inspection type 1 method A & method D, developer

form A.

Open tank system checked daily with appropriate test prior to conduct any

penetrant

inspections. Processed and inspected parts such as compressor fan, turbine

blades, disks,

spacers, static structures, stationary airfoils.

02-99/04-06 The Boeing Company San Antonio,Texas

Quality Control Process Analysis & Test Spec 1 (2-99/4-04)

Depaint Corrosion Mechanic (2-05/4-06)

Training: Certificate Penetrant class level 1 & 2, Magnetic Particle class

level 1 & 2

Training: Boeing NDT Record (PT level 2, MT level 1 ) MT Level 1 OJT 65

hours

Training: Respirator, Fod, Tool Control, Ethics, PPE, 5S

Training: Material Etching, Confined Space Entry, ISO 9000 class

Responsible for providing Fluorescent penetrant & Magnetic particle

inspection.

Flourescent Penetrant -type 1 method A water washable/ method C portable

removable

Magnetic Particle- Wet Continous method which includes head & coil shots,

demagnetization.

As required not limited to KC-10, KC-135, and C-17 military aircraft.

Provide back shop support

as well as hangar operations procedures. Work with drawings, T.O. 33-B-1-1

& ASTM 1417

process specifications, procedures.

09-94/02-99 EC Technologies San Antonio,Texas

Quality Control Inspector/NDI Inspector Level II

Training: Certificate Quality Inspector, Penetrant classroom 8 hours,

Flourescent Penetrant Certificate,

grit blasting, material etching, coating blades.

Responsible for performing incoming and final inspections of aircraft

components, jet engine blades

and vanes to be repaired per MFG guidelines, verify paperwork/certs.

Conduct Flourescent Penetrant

Inspection type I method A & method D. Performed daily system checks with

appropriate tests prior

to conduct any penetrant inspections per ASTM 1417.

Education

Southwest Texas State University, San Marcos, Texas- Basic Coursework

Austin Community College, Austin,Texas- Basic Coursework

Sheet Metal Training School- Swearingen Aviation Corporation

San Antonio, Texas

TWIC Card-Transportation Worker Identification Credential

Airmen Certification Record #A4422874



Contact this candidate