Lora L. Cantu
P.O. Box ***** San Antonio, TX. ***65
abodm9@r.postjobfree.com
Employment History
*-**-** /**-**-12 Spherion@Alcoa -Howmet Corporation, Wichita Falls,TX.
Penetrant Level II Inspector
Training: Certificate for 20 hours level II Penetrant class.
Training: Process & Inspecting aircraft components.
Flourescent Penetrant Inspection ASTM 1417/NAS 410
Water Washable Penetrant Type 1 method A & D, sensitivity level 3 & 4,
Form A developer.
Such customers include Solar, Pratt & Whitney, GE, Fiat, Rolls Royce, Pratt
Canada, Snecma, Honeywell.
Indications found are dross, inclusions, shrink, linears, plus metal, cold
shuts, and cracks.
2-9-11/2-24-12 Aerotek Aviation@ Chromalloy Dallas, Farmers Branch TX.
FPI Level II Inspector
Training: Penetrant OJT 1856 hours/ QCP-110 & NAS 410 Certificate
Training: Process & Inspecting aircraft components
Flourescent Penetrant inspection of jet engine parts for detection of open
to the surface discontinuities
in metallic/ non metallic, non porous materials and guideline of ASTM 1417
are being met. Daily checks performed on penetrant line Type 1 method D,
sensitivity level 4, Form A developer prior to any inspections. Parts
inspection on jet engine blades, vane segments, compressor blades, IPC
blade tip,
HPC Variable Vane, BPC blade tip. Customers include Pratt & Whitney, Rolls
Royce, KC-10, GE, IAE, CFMI.
Input data information in computer at this FAA Repair Station EN2R800K.
12-30-10/1-10-11 PQNDT@PCC Structurals, Franklin, New Hampshire
PT Level II Inspector
Training: NAS 410 Certificate
The ability to interpret specifications on castings which are processed
through Water Washable Penetrant method A and Form A developer. To be able
to certify the conformance of the castings
per customers requirements while maintain productivity. Daily system checks
at the beginning of
the shift prior to any inspections.
10-10/12-10 NIC@ Pratt & Whitney (Maine/Connecticut)
PT Level II Technician
Training: Non Destructive Evaluation Certificate and Cast Turbine Airfoil
OJT 248 hours includes
Environment Health & Safety Training Level 2 & 3.
Black light inspections on parts processed thru Flourescent Penetrant
Method A & D. Performed an acceptable system capability test at the
beginning of the shift prior to any inspections. Inspections are done by
part number which have specific standards & codes for that operation. Parts
includes cast
turbine airfoils, vane assy, jet engine blades which have been cast,
machined, welded, and coated.
Input data information in the Solumnia computer system.
08-08/06-10 National Oilwell Varco- Houston,Texas
Quality Control Receiving Inspector/ Quality Control Document Specialist
Training: Penetrant Class Level I & II for 12 hours, Magnetic Particle
Class Level I & II for 20 hours
Conduct Visual and Dimensional inspections for product compliance. Worked
with drawings, verify
quantity of parts received from vendor, material certs, hardness of
material, drawing revision. Wrote non-conformance reports. Utilized digital
calipers, ID Mic, OD Mic, No-go-gages, plug gage, radius gage.
Input data information into the Glovia computer system to clear parts to
stock in warehouse.
Assisted the Document Control Group for missing quality control
documents, such as Material Test Certs, Hydro Test Charts, Weld Maps, NDT
documents, and Data Books. Heavy computer research and
responsible for handling, scanning quality documents for our customers
data books. Established a new
relationship with vendors and middle management.
01-08/06-08 PQNDT@ Metal Tek International- Waukesha, Wisconsin
PT Level II Technician
Training: Penetrant Level II OJT 660 hours,Magnetic Particle Level II OJT
150 hours NAS 410
Training: Detergent & Steam cleaning, Safety procedures, PPE, Respirator
training, Operating equipment such as the hoist for loading and unloading
parts.
Performed a spray to waste electrostatic penetrant line. Performed method A
water washable spray, Flourescent Penetrant dye and red visble dye. Some
our parts include casting, manufactured parts,
manifold tubes, petro chemical tubes. Some our customers are Exxon Oil
Equistar, Midrex, Texas Eastman, CF Industries, GE, Rolls Royce, Boeing,
Chevron Phillips, Petro-Chem, Great Point Energy, etc.
Applicable techniques & specifications, codes, interpretation of
indications. Liquid Penetrant
procedures of ASME Section V and Section VIII Division I.
10-07/12-07 NIC@ Pratt & Whitney (Maine/Connecticut)
PT Level II Technician
Training: Certificate Cast Turbine Airfoil Level II OJT 201 hours
Training : Certificate NDT Record, Environment Health & Safety Training
Level II
Black light inspections on parts processed thru Flourescent Penetrant
method A & D. Performed an
acceptable system capability test at the beginning of the shift prior to
any inspections. Inspections
done by part number which standards & codes for that operation. Parts
include cast turbine airfoil,
vane assy, jet engine blades which have been cast, machined, welded, and
coated. Input data
information in the Solumnia computer system.
07-07/10-07 Dynatech Turbine Services San Antonio, Texas
FPI Level II Technician
Training: Certificate Visual Inspection Level II, FPI Level II NAS 410
Flourescent Penetrant Inspection type 1 method A & method D, developer
form A.
Open tank system checked daily with appropriate test prior to conduct any
penetrant
inspections. Processed and inspected parts such as compressor fan, turbine
blades, disks,
spacers, static structures, stationary airfoils.
02-99/04-06 The Boeing Company San Antonio,Texas
Quality Control Process Analysis & Test Spec 1 (2-99/4-04)
Depaint Corrosion Mechanic (2-05/4-06)
Training: Certificate Penetrant class level 1 & 2, Magnetic Particle class
level 1 & 2
Training: Boeing NDT Record (PT level 2, MT level 1 ) MT Level 1 OJT 65
hours
Training: Respirator, Fod, Tool Control, Ethics, PPE, 5S
Training: Material Etching, Confined Space Entry, ISO 9000 class
Responsible for providing Fluorescent penetrant & Magnetic particle
inspection.
Flourescent Penetrant -type 1 method A water washable/ method C portable
removable
Magnetic Particle- Wet Continous method which includes head & coil shots,
demagnetization.
As required not limited to KC-10, KC-135, and C-17 military aircraft.
Provide back shop support
as well as hangar operations procedures. Work with drawings, T.O. 33-B-1-1
& ASTM 1417
process specifications, procedures.
09-94/02-99 EC Technologies San Antonio,Texas
Quality Control Inspector/NDI Inspector Level II
Training: Certificate Quality Inspector, Penetrant classroom 8 hours,
Flourescent Penetrant Certificate,
grit blasting, material etching, coating blades.
Responsible for performing incoming and final inspections of aircraft
components, jet engine blades
and vanes to be repaired per MFG guidelines, verify paperwork/certs.
Conduct Flourescent Penetrant
Inspection type I method A & method D. Performed daily system checks with
appropriate tests prior
to conduct any penetrant inspections per ASTM 1417.
Education
Southwest Texas State University, San Marcos, Texas- Basic Coursework
Austin Community College, Austin,Texas- Basic Coursework
Sheet Metal Training School- Swearingen Aviation Corporation
San Antonio, Texas
TWIC Card-Transportation Worker Identification Credential
Airmen Certification Record #A4422874