Resume:

Reynaldo M. Balondo Tel. No: 1-951-***-**** / 951-***-****

***** ***** *** *****, ***. E39, E-mail Address: abhi5k@r.postjobfree.com

Temecula, CA, 92592.

Summary of Achievements and Qualifications:

Six (6) years work experience in the Operations & Maintenance of Power Substation.

Three(3)years work experience in Electrical Assembly/Wirings/Testing &Troubleshooting

Confident with MS Office 2007, Excel, Word, AutoCad 2008/2009 and Microstation.

Professional Experience

Electrical Panel Shop Technician November 2, 2009-Dec. 17,2010

Convergint Technologies, Calgary, AB, Canada

• Developed and implemented high standard panel shop, which include modification of

designs, panel box lay-out, material selection, directing control panel and switchgear.

• Panel assembly, wiring/soldering and testing according to drawings and materials.

Inspected of all finished panels for certification by CSA staff and made documentation.

• Tested/Repaired and troubleshoot various Security and Building Automation Control

Panels. Prepared reports for all the parts used and make an order parts if necessary.

• Maintained panel shop inventory and assisted with other various projects in the field.

Sales Associate (Part Time) April 10, 2009-May 6, 2010

Home Depot Tool Rental, Calgary, AB, Canada

• Performed cashiering/tagging works, opening, closing contracts & reported daily sales.

• Checked/repaired/tested various tools such as : Power Rake, Generator, Compressor,

Auger, Tiller, SOD Cutter, Aerator, Etc and make a replacement of parts if necessary

• Performed cleaning and arranged properly the stocks in the store before and after the

store open and close, make it sure that all stocks are available, if not, make an order.

Electrical Assembler(Panel Assembly/Technician) Oct. 30, 2007 – Feb. 5, 2009

Stewart & Stevenson,Calgary, AB, Canada

• Performed wiring/soldering and testing for the electrical installation of control panel as

specified by the oil and gas industry customers’ specifications and schematic diagrams.

• Attached components such as: breakers, relays, contactors, ground bars, insulators,

regulator cabinets, power supply controllers, meters, plugging devices, and fuse blocks

• Conducted/tested/repaired troubleshooting of all electrical and electronics equipment.

• Reviewed layout diagram for electrical and electronics installations according to specs.

• Installed/checked/tested of all electrical equipment using various tools such as hand and

power tools, multi-tester, megger, etc. Make a replacement of components if necessary.

• Wirings/testing/troubleshooting of different electrical equipment voltages such as : 120V,

208V, 240V, 277V, 480V, etc and conducted wirings/testing of various type of machines.

• Conducted/tested and meggered the wire resistance of different voltages to make it sure

the ohmmeter reading are within the limit and make a reports of the output readings.

• Conducted/tested/installed and terminated cables of 12V & 24V Battery DC Supply.

Accomplishments :

Accomplished and delivered more than fifty units of oil field equipment exported to different

country like China, Argentina, Russia, Texas, Etc.

Electrical Technician June 28, 2007 – Oct. 29, 2007

Sure Fire Industries,Calgary, AB Customers : Trican,Calfrac,Shlumberger

• Installed battery, equalizer, various gauges (voltmeter, ammeter, temperature & pressure),

circuit breakers, multifunction function display, converter, sensors, etc.

• Drilled and tapped holes in specified locations for mounting control units, using hand tools

and drill press in accordance with layout. Performed wiring/soldering installation and

conducted trouble shooting of defective electrical and Electronics equipment.

Reynaldo M. Balondo Tel. No.1-951-*******/951-***-****

Electrical Engineer April, 2001 – June, 2007

National Transmission Corporation(230KV,138KV, 69KV and 350KVDC) Cebu, Philippines

• Operated/monitored/recorded control room switches and equipment to effect efficient

transmission and synchronization of power to customers.

• Prepared and submitted reports to substation superintendent regarding interruption and

spot reports, indicating feeders/customers affected, duration, load involved, distance, time

and / or equipment in the substation.

• Prepared electrical wirings diagram using AUTOCAD such as : Distance Relay, Over

Current Relay, Over/Under Frequency Relay, etc

• Responsible for the maintenance, troubleshooting, repairing, installation and electrical

testing of the substation equipment such as : station batteries, chargers/rectifiers, auxiliary

switchboard, annunciator, relays/protections, meters, controls, switchboard components,

main power transformer, station service transformer, shunt reactor, capacitor bank,

groundings, PLC, control cables, switchgear, gas circuit breakers, oil circuit breakers,

insulators, lightning arresters, power structures, line hardware, communication

equipment, housekeeping and air conditioning system, etc.

• Installed and energized the following substation protection equipment : distance relays,

over current relays, over/under voltage relays, under/over frequency relays, etc

• Conducted/tested the quarterly/annual preventive maintenance activities of the following

substation protection equipment : distance relays, over current relays, over/under voltage

relays, under/over frequency relays, etc and make an adjustment of relays settings if

necessary, replace defective protection relays if necessary.

• Checked/Maintained the following electrical test instruments such as : Doble F6150,

Omicron 156 & 256, Sverker 650 & 750, Frequency Tester, Fluke Meters, Etc.

Accomplishments :

Commissioned & Energized two 150MVA transformers connected in parallel @ Compostela S/S

Commissioned & Energized 15KVAR capacitor bank @ Leizo Station.

Commissioned & Energized 69KV Veco-Banilad Feeder Distance Relay Protection.

Commissioned & Energized 230KV Tabango-Talisay Line submarine cable.

Installed & Energized thirty units under/over frequency relay.

Education :

University of the Visayas, Philippines

B.S. in Electrical Engineering (Diploma) October, 1997

Trainings/Continuing Education/Professional Development:

Electrical Design Certificate, SAIT, Calgary, AB, Canada April, 2010

Professional Associations :

The Association of Science and Engineering Technology, Professional Certified Engineering

Alberta, Canada (ASET) Technician(Electrical)