Post Job Free

Resume

Sign in

Quality Assurance Manager

Location:
Montegut, LA, 70377
Posted:
November 20, 2010

Contact this candidate

Resume:

Cleo Callais

Cell- 985-***-****

*** ******* **

Home- 985-***-****

Montegut La 70377

Cleophas "Cleo" A. Callais Jr.

Career Experience

**/**** - ******* ********* *********

Lockport, La

Quality Inspector

Perform quality assurance inspections on US Coast

Guard vessels. Performing visual inspections, air

testing & hydro testing on superstructers & piping.

10/2008 - 10/2010 Paloma Energy

Consultants Houston, TX

Project Inspector

Ensure that all construction activities are

performed in accordance with the Contract

Documents, specifications, and latest applicable

codes. Document material traceability, plans,

coordinates, and executes offshore installations,

hookups, and abandonment's. Keep detailed job

costs and provides detailed daily reports to the

client.

Performed Level II & Level III inspections on

several platforms & caissons in gulf for ERT &

McMoRan.

Spent time doing Worksite Clearance Verification at

HI A 327 for Arena Offshore, completed all pulls on

grid, went back out to location with dive boat to

recover snagged net off bottom,

Performed Level II inspections at WC 324 C, VR 331

A,

Worked on hydrotest of 2" riser, installed riser at

EI 158 #14 using a smart flange

Fabricated and hydro tested tie in spool for VR 340

A

Worked on survey vessel recording data of pipeline

in the HI 332 area

Worked on laybarge to install dual pipelines (6" &

2") from SS 186 C to SS 189 A also installed riser

clamps on platform, installed risers, tie in spools

& closing spools.

Installed 30" x 10" hot tap for Arena at SMI 192

using sat divers, installed tap, 2 hour test on

seal performed, installed 10" SSTI, jetted down to

grade & covered with 3 in 1 bags

Installed davit arm on platform at GI 82 to assist

in the installation of a halo clamp at that same

location

Did P & A on pipeline at PL 12 & VR 64 -1

Worked on jacket repairs at EC 346A, grouted jacket

legs & 2 X-braces, installed clamps to hold grout

in place till set.

Installed 15 anode pods on platform at ST 63A

Cleophas "Cleo" A. Callais jr.

Project Inspector

Page 2

Installed single retrobuoy anode at SS 223B, dual

retrobuoy anodes at SS 224 B, & another set of dual

retrobuoys at SMI 130 C

Installed dual pipeline risers (6" & 2") at VR 195

A platform, installed clamps, risers, closing spool

& tie in spools for both risers, hydro tested lines

8 hours, de-watered lines and left lines with 5 psi

of nitrogen

Repaired subsea conductor guide framing at SS 225B,

pulled guide up to clamps & pulled bottom clamps up

against bottom of CGF. Changes all hardware on all

clamps.

Removing 8" pipeline riser damaged by hurricane at

EI 349 B, removing oil out of lines into cut box,

remove all above water riser pipe, move pig

launcher down to +10 elevation.

Worked at Pelto 20 removing 6 caisson platforms

using explosives & mechanical cutting.

Ran cleaning pigs in riser from EI 349 B to do

pipeline abandonment on line. Ran pigs, cut riser

pipe at base of platform, removed 25' section of

pipeline at SSTI, plugged both open ends of pipe.

Completed pipeline abandonment then relocated to

platform at EI 349 B to perform un-manning

platform. Cleaned out all drains, placed sumps in

by-pass, removed generators & helicopter fuel

tanks, cleaned out living quarters & locked up

platform for removal in spring.

Repaired and replaced braces at -53 fsw, installed

welding habitat at level and removed dented brace

and installed new brace with weld sleeve. Made 1

dry weld in habitat and 4 wet welds throughout

platform.

Performed site clearance at Pelto 20 to complete

caisson removal procedures performed earlier at

same location.

Built 180' 3- pile platform for Newfield

Exploration Company at Gulf Island Fab in Houma,

Package consisted of Structure, Piles & riser

Performed subsea inspections (Level II & Level III)

at Ship Shoal 223A & Vr 182 JB. Performed swim by

inspections and level III on 4 selected nodes of

both platforms

Installed sleeve on dented caisson at West Cameron

290 A, Installed Sleeve at +10' elevation, removed

bent grating on deck and replaced channels &

grating

Performed Subsea inspections at HI 557-A & MI 604 A

for ERT. Performed swim by inspections and Level

III inspections on selected nodes, one indication

was found and performed MT inspection on indication

Spooling flowlines, fuel gas lines, compressor

piping & departing pipeline piping spools for

Dynamic Offshore Resources. Lines being installed

at EI 7 & 10

Installed 17,000' of pipeline for Newfield at WD 72

, preformed 6 pipeline crossings, ran cleaning &

sizing pigs through pipeline

Installed Boatlanding clamp with divers & stabbed

boatlanding onto platform at GI 78 A, Pumped grout

into clamps on bracing

Replaced U-bolts on riser with caps at PL 25 #2.

Removed broken u-bolts & installed caps, did video

inspection of work performed

Completed pipeline crossings & tie in of pipeline

to riser @ WD 72 B & tie in at SSVA at WD 65

Cleophas "Cleo" A. Callais jr.

Project Inspector

Page 3

July 2008 - Oct 2008 Pinnacle

Project Services

Construction Coordinator

On various projects in the Gulf performed SSTI

inspections and removal, Level IV inspections,

installed pipelines and risers on platforms.

Experience in fabrication, piping, and painting.

6/2007 - 7/2008 Partek Laboratories

Responsible for monitoring welding procedures in

shop and offsite. Tested welders to AWS, ASME, &

API codes.

5/2003 - 6/2007 Offshore Specialty

Fabricators

Quality Control Manager

Maintain material certs, welder certs, dimensional

control on all decks and jackets built, responsible

for completion of job data books, responsible for

testing of well control panels, generator systems,

hydrostatic testing of manifolds & piping systems.

Environmental Manager

Worked with DEQ & Environmental consultants to get

all required permits written and implemented.

Assist the safety department. NDE Level II Liquid

Penetrant Inspector, Maritime Confined Space Safety

Practices.

10/1997 - 5/2003 Bollinger Shipyards,

LLC

Safety Director

Worked as medic, handled all aspects of safety

program. Trained all employees

on OSHA required safety program, Chairman of Safety

Committee, contributed in the writing and

implementation of Bollinger Safety Handbook, and

completed all OSHA monthly, semi-annual and annual

repo

Quality Coordinator

Ensure the implementation of the ISO 9001 system at

the Larose yard.

Maintained all reports and procedures as required.

Certified Internal Auditor for ISO system.

Environmental Coordinator

Maintained all environmental records and reporting

for Larose facility, Supervisor for Environmental

Emergency Response Team.

Human Resources Rep

Interviewed new hires, conducted all safety,

environmental, and quality orientations for new

employees.

Welding Inspector

Tested new welding & fitting applicants prior to

hiring.

10/1985 - 10/1997 Gulf Island

Fabricators

Structural & Pipe Welder

6gr & 6g certified, SMAW, GTAW, FCAW, and GMAW.

10/1984 - 10/1985 Hope Contractors

Structural & Pipe Welder, Welding Supervisor

Training & certifications

2008 Offshore Water Survival (H.U.E.T.)

Scott, LA

11 years CWI - Certified Welding Inspector

1992 NREMT - National Registered Emergency Medical

Technician

ISO 9000 Upgrade 2000 Transition Training

ISO 9000 Internal Auditor

Respirator Training Instructor

Shipyard Safety Train the Trainer

LSU FETI HazMat Awareness Level - 4 hours

LSU FETI HazMat Operations Level - 24 hours

Former Hazwoper Instructor

Dale Carnegie Course

NFA Incident Command System

Certified Firefighter I

Certified Firefighter II

Certified Firefighter Instructor I

Education

1975 South Terrebonne High School

Bourg, LA



Contact this candidate