FORMAT FOR BIO DATA
*. Name R.R.JOSHI
*. Date Of Birth 27.07.1957
3. Nationality Indian
4. Contact Details RAGHAVENDRA R JOSHI
Address “SRINIKETANA” BEHIND POLICE QTRS.,HARLAPURA EXTN.HARIHAR-577602 ,KARNATAKA
Phone Number: 098********
Email id: *******.****@*****.***
5. Languages Know (Read, Write, Speak)
English, Hindi & Kannada
6. Educational Qualifications for all degree Indication year of Completion,
name of College/ University DME (Mechanical)
Year of Completion: 1984
College / University: Board of Technical Examination, Karnataka
Full Time / part Time: Full Time
7. Passport no. and validity period G2027467 , From 12/03/2007 to 11/03/2017
8. Affiliations to Professional Bodies ---
9. Certification ASNT/ ISNT etc. ASNT Level II in RT,UT, MT and PT
10. Present Employment Status
FROM 2008 TO TILL DATE WORKING IN “ Germanischer Lloyd
Industrial Services India pvt ltd.”
• FROM DECEMBER 2010 TO TILL DATE WORKING AS TPI FOR GAIL INDIA LTD.’S 1000km 30/36 INCH PIPE LINE (CONSTRUCTION) PROJECT WHICH PASSING THROUGH MAHARASTRA/KARNATAKA STATE ,INDIA
• CONTRACTOR: M/S PUNJ LLOYD LTD.
• PROJECT MANAGEMENT CONSULTANT:M/S ENGINEERS INDIA LTD
11. Professional Experience: Experience related to Pipe Coating / pipe Manufacturing / pipeline Construction to be indicated under each head in line with the job requirement.
Please refer enclosure for details.
12. Computer & Software’s Proficiency Proficiency in MS Office
13. Any other information: TOTAL EXPEREINCE : 28 YEARS EXPERIENCE IN TPI ACTIVITIES : 10 YEARS TPI OF PIPE LAYING : 3 YEARS
TPI OF LINE PIPES : 3 YEARS
TPI OF STORAGE TANKS (REFINERY &PETROCHEMICALS) : 1YEAR 6 MONTHS
Organization PERIOD Years Position Project Name Responsibilities
From To
Germanischer
Lloyd Industrial
Services India
Pvt. Ltd. 2008 Till
Date 4 Sr.Inspection
Engineer Ruby pipe line project Inspection of coated line pipes API
5L X- 70 PSL-2 SPIRAL-SAW
48”x13.74/18.31/21.97mm /
42”x13.74/15.24 mm -250Kms at the pipe mill of M/s. Welspun, Anjar.
Guadalajara pipeline project Inspection of coated line pipes API
5L X- 70 PSL-2 SPIRAL-SAW
30”x15.59/12.24/10.21/8.51mm WT
36”x15.7/12.26 - 210 Kms at the pipe mill of M/s. Welspun, Anjar for M/s.Transcanada pipeline limited
Sabah-Sarawak gas pipeline(SSGP) Project Inspection of line pipes API 5L X-
70 PSL-2 SPIRAL-SAW
36”x16.76mm WT - 75 kms at the pipe mill of M/s. Welspun, Anjar for M/s.Petro - pipe(Sabah)
Mangalore Refinery & Petrochemicals ltd.,Mangalore, India TPI for fabricated storage tanks likes cone roof, floating roof (single deck & double deck), Dome roof to API 650 standard in sizes diameter from 12 mtrs. To 60 mtrs. & 18 mtrs.height
Quality
Evaluation and system team pvt.ltd. Bangalore
(on behalf of
L&T Ltd.) 2007 2008 1 Principal surveyor Hypersonic wind
tunnel project The main activity is to carry out 20”
Water cooling pipe line erection and inspection of Valves, pipes, Heater system, Nozzles, Safety relief valves etc. At M/s. Vikram Sarabai Space centre, Thiruvananthapuram
Medikonda
Construction Pvt
Ltd
(On Deputation
to Reliance) 2006 2007 2 QC Engineer Kakinada-
Kothadu pipeline
project for
Reliance
48” --248 Kms Inspection of pipe fittings.
Welding inspection, checking fit up, bevel angle, preheating.
Sand blasting, HDPE coating, Epoxy coating.
Conducting welder Qualification.
Welding inspection through radiography test.
Checking the weld quality and
Thickness of weld bead with ultrasonic sound test.
RT Films interpretation.
Coordination with TPIA & clients.
BEML,KGF
(On behalf of M/s Nathan and Nathan consultancy pvt ltd.) 2001 2005 5 Sr.Inspection
Engineer Various
projects Inspection of weldments of
Sheet metal, fabrication, different types of pipes.
Inspection of process of
Welding with respect to process monitoring sheet.
Carrying out liquid
Penetration test/Dye penetration test to be carried out after welding to find cracks, porosity, blowholes and other defects.
Visual inspection of welding to ensure of free from
cavity, gas pore, worm hole,shrinkage,slag
inclusion, incomplete fusion and penetration, excess penetration, overlap,
Discontinuity, misalignment and spatters.
Conducting mechanical test
Like hardness in different scales, Jominy hardenablity test, tensile strength, yieldstrength, impact energy, reduction in area, bend test, flattening test on test pieces as per specifications/standards.
Verification of vendor TC co-relation to job, linkage between reference documents.
Witnessing of chemical analysis on spectrometer,
Line spectro.
Verification of microstructure of material
with reference to specified
Specimen.
Verification /witnessing of
Critical machined in metrology/CMM for angularity, flatness, roundness, cylindricity, co- axiality, surface roughness, profile error etc.
Pressure testing of castings, pipes to ensure leak-proof, crack proof as per standard and drawing.
Verification of photographs for macro etch/grain flow
pattern for soundness of
Forging.
The Mysore
Kirloskar Ltd, Harihar.
(A reputed
Machine tool manufacturer) 198*-****-** Quality
Manager Various Projects Monitoring the periodical
Calibration of instrument, gauges, Surface, granite/ Plate etc.
Handling of sophisticated instrument & gauges both in
Mechanical and electronics/Digital.
Conducting internal audit
ISO 9001:2000.
Preparing of formats of checklist, inspection report,
Test chart for parts, machines and job order work.
Analyzing the customer complaint on parts, machine
and its sub assemblies/product etc.Detailed investigation
carried out on nature of complaint. If need to correct, corrective action will be
taken with relevant coordinating department
Creating of history files for
Long period documenting on each machines/product.
Attending customer
Complaints on quality at their inspecting try out components before installation and after commissioning of machine as per customer drawing requirement if trails carried out at their end will be inspected there with relevant process capability acceptance norms.
I hereby declare that all the above mentioned statements are true to the best of my knowledge and belief.