Resume of Gopichandran * P a g e
S. GOPICHANDRAN
No: 3/30, Vellalar Street, Venkatachalapuram, Thuraiyur Trichy Tamil Nadu India-621011
Mobile: +91-979*******, Email: **************@*****.*** CAREER OBJECTIVE
“I am seeking an opportunity to merge my initiative, enthusiasm with 8+ Years of proficiency to add value, both to the organization and myself. To aim at expanding my horizons and developing skills in the field of “Quality Management – Electrical
& Instrument ” and to work in a dynamic environment that provides opportunities for my growth.” AREAS OF EXPERTISE
Quality Management Testing & Inspection Cathode Protection System
Risk Assessment Hazard Management Electrical Equipment Installations
Preventive Maintenance Control System Instrument Equipment Installations ACADEMIC SKILLS
B.E. [Electronics & Instrumentation Engg.]
from J.J College of Engg. & Tech., Trichy -
2010
IT SKILLS
MS-Office
AutoCAD
Windows 2000/XP/7/8.1/10
CERTIFICATIONS
Diploma [Electrical CAD] – PentaCAD,
Salem – 2015
SYNOPSIS
Good in Project Quality System (Procedures, ITPs, NCR, QAR, FAT, Material handlings & Site Inspections with knowledge in ISO, IEEE standards).
Possess core knowledge in Site Installation Supervisions, Integration & Hook-up with honed problem solving and analytical abilities, Process Instrument Calibrations, Loop, Sequence & Testing.
Knowledge in MV/LV Switchgear systems, Telecom, Fire Alarm, ACS and CCTV System.
Good in HSE culture (PTW, LOTO, Method statements, JSA, RA, PPE, tool box meetings).
Familiar in documentation controls with DOCUMENTUM, ICAPS and Team Binder tools.
Expertise in Cathode Protection System.
Involved in Installations inspection of all types of Instrument Equipment. WORK EXPERIENCE
Sri Vengateswara Electric Services, Chennai
Jan 2019 to till date
Apr 2017 to Mar 2018
Designation: E & I Engineer
Roles & Responsibilities:-
Coordinated with the contractors and suppliers and maintained good working relations.
Prepared technical documents and ensured that the work was carried according to the drawings and specifications.
Switchgears & panel Accessories installation, Circuit Breakers installation and testing.
Installation and troubleshooting of Motor starter, MCC & Control panels, Variable Frequency Drives.
Installation and trouble shooting of Automation panels, Pressure transmitters, etc.
Maintained the different phases of the project and evaluated all the technical problems and resolved them. Ensured that work was completed in accordance with the project schedule and the construction contract. Rotary Mec (M) Sdn Bhd, Malaysia Apr 2018 to Oct 2018 Designation: E & I Inspector QA/QC
Roles & Responsibilities:-
Involved in Construction verifications, testing with Project Quality Plan, Inspection Test Plan and Preventive / Corrective Actions for Non-Conformances and Punch points.
Responsible to verify that company procedures and process are being implemented in accordance with the Project Quality Program.
Involved in calibration of all types of instruments such as transmitters, switches, temperature elements, pressure elements etc.
Generate RFIs where required providing sufficient notice for Hold, Witness and other Inspection levels and Coordinate with client representatives to ensure that inspections are carried out expediently.
Preparing and maintaining calibration records, instrument history record, instrument list, calibration planner, instrument classification, etc.,
Having hands on experience on Calibration of instruments like differential pressure transmitter, Thermocouple, Temperature Gauge, pressure Gauge, flow meters, level transmitters, pressure transmitters, flow transmitters, Temperature transmitter, Capacitance Level Transmitter, FCA, control valves.
Inspect vendor documentation to ensure compliance with the Inspection & Test Plan and purchase orders.
Inspect the product quality to establish if the client requirements are being achieved.
Perform a variety of inspection functions as identified in the approved Inspection and Test Plan (ITP). Resume of Gopichandran 2 P a g e
Inspect installed equipment and ensure equipment and materials are ready for construction, maintenance and operations.
React to the daily inspection needs and provide expertise in the inspection of a wide array of equipment’s and installations.
Prioritize maintenance activities ensuring all equipment within the facility are serviced to an acceptable standard in a timely and safe manner.
CLIENT NAME PROJECT NAME PROJECT SCOPE DURATION
PENGERANG INTEGRATED
COMPLEX, Malaysia.
RAPID Project Apr 2018 – Oct 2018
Samsung Engineering Co. Ltd., Iraq Dec 2013 to Dec 2016 Designation: E & I Inspector – QA/ QC
“Samsung Engineering has grown from a modest domestic engineering firm to a globally recognized name in the EPC market. Attracting talent from around the world, Samsung Engineering has broadened its business portfolio to a full range of engineering services: upstream and downstream hydrocarbon facilities; power plants; water and waste treatment plants; and industrial production facilities.” Roles & Responsibilities:
Involved in Construction verifications, testing with Project Quality Plan, Inspection Test Plan and Preventive / Corrective Actions for Non-Conformances and Punch points.
Responsible to verify that company procedures and process are being implemented in accordance with the Project Quality Program.
Generate RFIs where required providing sufficient notice for Hold, Witness and other Inspection levels and Coordinate with client representatives to ensure that inspections are carried out expediently.
Inspect vendor documentation to ensure compliance with the Inspection & Test Plan and purchase orders.
Inspect the product quality to establish if the client requirements are being achieved.
Perform a variety of inspection functions as identified in the approved Inspection and Test Plan (ITP).
Inspect installed equipment and ensure equipment and materials are ready for construction, maintenance and operations.
React to the daily inspection needs and provide expertise in the inspection of a wide array of equipment’s and installations.
Expertise in Transformer rectifier unit, M.M.O Ribbon Anode, M.M.O Tubular Anode, Aluminium Anode, Reference Electrode, Bonding cable with CAD welding, Deep well ground bed, Test box and Junction box installation and Testing for CP system (UG pipeline, Water & Oil storage Tank, Well pads & Truck lines).
Carry out final inspections to ensure compliance with the Project requirements.
Record and document any and all deviations from the Project Quality Program and Specifications.
Coordination with Safety, Site superintendents, Commissioning manger, interfaces with Mechanical, Piping, Welding, Scaffold and Lifting disciplines and reporting to Senior Project Manager.
Organize of Quality meeting and participate weekly minutes of meetings, daily safety and progress meetings.
FAT witnessing final test and SAT arrangements at Onshore.
Verification of reassemble works to commission in Electrical and Instrument Telecom Technical Rooms – retest cables, bus bars, Marshaling / System cabinets, UPS, HVAC, Lighting & Earth network.
Implement and recording all test results to verification for Compressors, Drain System, Chemical Injection, Wellhead Controls, Telecom, Navigational Aids, Cathodic Protections, Earth system, etc.,
Confirm fabrication and installation of cable ladders/trays - types, sizes, pulling and dressing arrangements, glands, test and terminations against cable schedule, routing diagram to JB and marshaling panels, termination and loop drawing, vendor cable drawings.
Verify Engineering documents of layouts, circuit and block diagrams, hook-ups, data sheet, P&IDs, TQ and red line as- built drawings.
Frequent check of Material storage / Instrument arrangement in Warehouse and valid calibration certifications.
Support to turn over activities - Final document MC dossier handover – FAT, ATEX Certificate Conformities, NCRs, Test records, Material certificates, Spare parts, etc.,
Involved in Inspection of,
Electrical Panel Instrument Panel PG/LG/PT/LT Installation Cable Termination
Bus Bar Torque Transformer [Testing] Fire Alarm logic Check Cathodic protection
AC UPS Panel DC Charger Battery Installation Telecom System
RTD Junction Box Winding Resistance Heat Tracing Panel Heat Tracing Cable Laying
Fire Fighting Switch Gear Panel Fire Alarm Loop Check Security System
Lighting panels MV/ LV Motor Fire Alarm Normal Lighting Panel PROJECT HANDLED:
CLIENT NAME PROJECT NAME PROJECT SCOPE DURATION
West Qurna Phase-2 Project, Iraq. Mishrif CPF & Gathering Project Dec 2013 – Dec 2016 Resume of Gopichandran 3 P a g e
Innovative Control System, Hosur Jun 2010 to Aug 2013 Designation: Electrical Inspector – QA/ QC
“Innovative Control System is a one of leading Company in Testing, Inspection and Certification (TIC). Delivering high quality services to help clients meet the growing challenges of quality, safety, environmental protection and social responsibility.” Roles & Responsibilities:-
Prepare and study technical drawings and specifications of electrical systems to ensure that installations and operations.
Involved in assembling, installing, testing, and maintaining of electrical equipment like,
UPS System/ Generator
DC Charger
Panel & Distribution Switchboards
Electrical Circuits, Control & Protection Circuits.
Ground Earthing System & Fire Alarm System
Schedule and undertake periodic inspection on all electrical equipment, components, and installations.
Carry out final inspections to ensure compliance with the Project requirements.
Perform a variety of inspection functions as identified in the approved Inspection and Test Plan (ITP).
Preparation and Inspection of procedure qualification tests.
Participate in review of construction, QC documents (Quality Control Plan, Procedures, Method Statements, Inspection & Test Plan) in accordance with company requirements.
Installation & Testing Inspection of Switchgear Panel and Power transformer in Substation.
Installation inspection of auto control system instruments.
Installation & Testing inspection of power and lighting distribution switchboards.
Installation & Testing inspection of 180KW UPS for power distribution.
Installation & Testing inspection of Fire Alarm System CORE COMPENTENCIES
Professional, growth oriented, easy adaptive and quick learner.
Talented, independent, responsible, hardworking and efficient in analytical complex solving issues.
An extrovert with very good blending capabilities.
An absolute team player with good communication skills.
Ability to deal with a diverse range of cultures and nationalities internationally.
Highly competent self-motivated, hardworking with the ability to rapidly learn and apply new skills. PERSONAL DETAILS
Name S. Gopichandran Languages English, Tamil
Father’s Name R. Subbaiya Date of Birth 24-09-1988 Sex Male Marital Status Married
Nationality Indian Passport No J3610137
Age 30 Native Place Trichy
DECLARATION
I (S. Gopichandran) hereby declare that the above information given by me is true to the best of my knowledge. Place: Yours Sincerely,
Date:
(S. Gopichandran)