Post Job Free

Resume

Sign in

Pipeline Engineer

Location:
Angleton, TX, 77515
Posted:
February 11, 2017

Contact this candidate

Original resume on Jobvertise

Resume:

Tayo Fawehinmi

Phone Number: 832-***-**** Email: acyrym@r.postjobfree.com

RELEVANT ENGINEERING EXPERIENCE

Spectra Energy

Pipeline Integrity Engineer

December 2014-

Installation, AC Modeling & Mitigation in South East Region for BIG and Baytown segments

Manage Direct Assessment and Unpiggable pipe program

Manage Revetment and Erosion Control Remediation on Transmission Pipelines

Reviewing Pipeline Shutdown Procedures

Performed functions such as ILI analysis, safe pressure calculations and anomaly repair

decisions.

Prepare Purchase Requests for pressure containing equipment

Prepare Hydrostatic Test Letters as required Assist Southeast Region in obtaining its

Provide Technical Support to Area

Plan future program enhancements and cost reductions

work on ROW for DOT pipe replacements

Review, analyze and approve pipeline shut down procedures

Participate in Engineering New Construction Project reviews for Stratton Ridge and STEP

Aerotek (assigned to Spectra Energy Gas Transmission)

April 2013 December 2014

PIPELINE INTEGRITY SPECIALIST

Review and analyze historic ILI data to investigate for anomalies, using the criteria

established in 49 C.F.R. Subpart O.

Update central database with all repair works.

ILI data management

University of Houston/BP-Set Laboratories

June 2011February 2013

CORROSION RESEARCH ENGINEER

Corrosion Tests for materials used in high temperature and high pressure oil production

processes.

Writing procedures and reports for chemical compatibility tests of various corrosion inhibitors

and biocides.

Conducting and supervising Microbial corrosion tests.

Evaluation of corrosion inhibitors used by BP, Baker Hughes, Schlumberger, Exxon Mobil in

acidic oil processes.

Pitting evaluation of materials based on ASTM G46

AES

November 2010June 2011

INTEGRITY ENGINEER

Project leader for integrity assessment on above ground storage tanks and pipelines in

various locations using MFL, LRUT and other techniques.

Led underground pipeline integrity assessment of 28 inch and 24 inch lines flow lines using

long-range ultrasonics

Led aboveground pipeline integrity assessment of 30 inches, 20, 8 and 6 inches lines using

long-range ultrasonics and conventional ultrasonics

Supervised crude oil tank inspection (bottom plates, annular, reinforcement plates and

external shell) and confirming level of cleanliness

Led UT, MPI, DPI, VT inspection and supervision of 61m diameter tank farm welds and

plates.

Supervised 61m diameter crude oil tank farm cleaning and sludge removal.

Produced location report of NDT methods and results (MPI, DPI, UT, Leak Test)

Produced daily work done template and estimated percentage of work done into project

schedule.

Carried out Cathodic Protection survey and continuity checking in crude oil tank installation.

Carried out survey and produced tank shells and bottoms drawing via AutoCAD.

ElectrotechCP

October 2008January 2010

ASSISTANT CATHODIC PROTECTION ENGINEER

A contract position in which responsibility was to provide technical support services to the

Operations and Engineering groups in the area of cathodic protection system design and

data interpretation.

Responsibilities: Field Work, Report Writing, Adhering to Quality Management System (BSEN)

Produced cathodic monitoring report based on monthly depolarization

Analyzed tri monthly cathodic protection monitoring data for all clients based on instant off

potentials and structures depolarization behavior.

Via CP data identified local rectifying units falling short on compliance criteria

Designed with senior engineer CP system for offshore concrete structures.

Updated maps, data files, and drawings related to corrosion control

Carried out monitoring of corrosion control systems and making snagging depolarization

tests.

Made AutoCAD drawings of cathodic protection designs for Sale Swimming Pool Leisure

centre.

Made AutoCAD drawings of corrosion control designs for pipeline bridge in Cumbria

Fungtai Engineering Company

August 2006September 2007

ASSISTANT RESIDENT ENGINEER

The work experience entailed ensuring projects were constructed in accordance with

contract agreement design, budget, and schedule. I was also reporting and sending

reports to management on the pace of the work and problems that we were facing as the

structural engineering team and revising contract drawings using AutoCAD

While there I was able contribute to do the following:

Revised contracts drawings of reinforced concrete piles and tie back walls using AutoCAD

2004

Improved quality control by carrying out fortnightly laboratory testing of materials (tensile and

cube testing of iron rods and concrete) used on site.

Solved the premature precast concrete pile cracking problem during lifting via statics

calculations.

Proposed the use of galvanized steel rebar for reinforced concrete shoreline protector.

Converted an existing building into AutoCAD drawings and presenting all elevations.

Ensured masonry work was as specified and measuring centre to centre spacings between

reinforcements and links.

Supervised construction work on Construction of Apapa Dockyard Berths 1-3 and Oil Depot

jetty.

Ensured integrity of steel cages to be used and made sure work men adhere strictly to

specifications.

Trained laborers to carry out slump test on concrete that was mixed.

Investigated internal flaws in piles with ultrasonic thickness detector.

Timely submission of project progress reports and revising bills of quantities.

Revising bill of quantities and estimating total amount of work done

Ensured safety on the site by mandating that all contractors workers must be fully kitted with

safety apparel.

Continental Shipyard Limited Dockyard Quays Apapa Lagos

April 2001August 2003

(A Joint Venture between D.E.S Geneva and N.P.A)

INDUSTRIAL ATTACHMENT

Provided NDT on repaired vessels

Identified areas with coating defects via the use of coating gauge.

Used wet sponge low voltage holiday detector to check for porosities.

Conducted NDT of welds using DPI, MPI on welded areas of ship or vessel hull

EDUCATION

The University of Manchester

September 2007September 2008

Corrosion and Protection Centre

M.S. in Corrosion Control Science and Engineering

Comparison of pitting behaviour of AISI 304 and mild steel in concrete

pour using potentiodynamic scansthesis

Obafemi Awolowo University Ile-Ife

January 1997August 2003

Bachelor of Science in Metallurgical and Materials Engineering

Corrosion Inhibition efficiency of theobroma cacao and cola acuminata on mild steel in sea

water

The Welding Institute Cambridge

February 2011

Guided Wave Pipe Inspection

Setting up equipments, Ultrasonic tests, Drawings, Identifying Pipe Features, Interpreting,

Amplitude-Scans, Creating Locations reports, Plant Integrity Software

NDT Training Center Houston

June 2011

NACE CERTIFICATIONS (National Association of Corrosion Engineers) Houston, Texas

NACE CP Certified Cathodic Protection Technician 1 #19868

NACE CIP Certified Coating Inspector Designing for Corrosion Control

Member NACE #211774, Member Institute of Corrosion & Society of Petroleum Engineers

ASNT UT LEVEL II

API 570 Certification

ASNT VT LEVEL II

ENGINEERING SOFTWARE

AutoCAD, Corrware, Oldham, Pipe Stress, Norsok, Plant Integrity and

Cassandra



Contact this candidate