CURRICULUM-VITAE
MR. MAHESH RAMESH DERKE
Address : Room N 2134/002,
Mari Aei Chowk,Vitthal,
Temple Road,Shankar
Buwa Wadi,Ghansoli,
Navi Mumbai - 400701
Email id : acypif@r.postjobfree.com
Cell : 771-***-****/810-***-****
Post Applied For : RIG ELECTRICIAN
OBJECTIVE
To find a challenging and responsible position in a professional environment, where I can contribute to growth and success of an organization to help maximum performance and overall organization satisfaction.
PERSONAL DETAILS
Name : Mr. Mahesh Ramesh Derke
Father’s Name : Shri. Ramesh Shankar Derke
Mother’s Name : Smt. Asha Ramesh Derke
Wife’s Name : Smt.Rutuja Mahesh Derke
Date of Birth : 22.09.1987, {MH}
Nationality /Religion : Indian /Hindu
Marital Status : Married
Permanent Address : Room No 2134/002,Mari Aei Chowk,
Vitthal Temple Road,Shankar
Buwa Wadi,Ghansoli,
Navi Mumbai - 400701
Cell : 771-***-****/810-***-****
Language Known : Marathi,Hindi & English
Educational Details
HSC PASS
Technical Qualification
DIPLOMA IN INDUSTRIAL ELECTRICAL
Knowledge of computer related subject
Mictrosoft office & internet
BASIC OFFSHORE SAFETY INDUCTION AND EMERGENCY TRAINING
•OFFSHORE SAFETY INDUCTION
•HELICOPTER UNDERWATER ESCAPE TRAINING.
•PERSONAL SEA SURVIVAL TECHNIQUES.
•FIRE PREVENTATION & FIRE FIGHTING .
•HYDROGEN SULPHATE SAFETY.
•ELEMENTRY FIRST AID.
ISSUE AT MUMBAI THIS 09TH DAY OF OCT.2014 VALID FOR 3 YEARS DATE OF ISSUE.
Passport Details
Passport No. : H 2032253
Date of Issue : 30.12.2008
Date of Expiry : 29.12.2018
Place of Issue : THANE
WORK EXPERIENCE IN INDIA
Company name : JINDAL PIPES LIMITED
Position : Rig Electrician
Period : 16.03.2015 to 27.12.2016
Company name : M/S. GMMCO LIMITED
Position : Service Electrician
Period : 11.10.2014 to 03.03.2015
Company name : Prabhat Powertech Pvt Ltd
Position : Site Incharge
Period : 7.11.2012 to 15.06.2014
Company name : SPAM MARINE CUNSULTANT
Position : Electrician
Period : 20.11.2010 to 12.10.2012
Company name : POWER VISION PVT LTD
Position : Electrician
Period : 1.10.2008 to 12.02.2009
WORK EXPERIENCE IN ABBROAD
Company name : CROMPTON INTERNATIONAL TRADING & CO. WLL
Position : Industrial Electrician
Period : 15.03.2009 to 13.09.2009
Company name : KHALID ELECTRICAL & MECANICAL EST WLL
Position : Industrial Electrician
Period : 15.10.2009 to 01.1.2010
Technical Knowledge & Work Experience
Supporting Jindal Virtue-I Cyber JackUp Rig (Make-Keppel FELS) as an Electrician Technician
•Top Drive System - 8SA – 1150HP (750 S/Ton – VFD, SBC Controlled-PROFIBUS DP Technology.).
•Automated DrawWorks System – ADS-10T (3000HP – VFD, SBC Controlled).
•Triplex Mud Pumps – 14-P-220 (2200HP – VFD, ABB PLC Controlled).
•Varco Compact Racker.
•AC Rotary Table – 1150HP (VFD, SBC Controlled).
•BOP – PLC Controlled (Siemens S7 PLC).
As an ET - Performing Troubleshooting and Maintenance activities on Other Rig Supporting Equipments that includes -
•Centrifuge Pumps – NOV Brandt Model 1850 Centrifuge (60HP VFD for Bowl speed control)
•Shale Shakers – VSM 300 Shale shakers (11KW VFD Controlled - 690+ series Parker AC Drives for speed control of 3-Phase AC Induction Motor)
•Cranes- Make:Favelle Favco-50 Ton Crane Instrumentation
•Rig Lighting system – Flood Lights/Tube Lights
•Centralized as well as Split Air Conditioning System
•Power Management and Distribution System – ABB Advant Control System Multidrive (ACS 800M - ABB PLC Controlled) By ABB
•LV Switchboards/LV Switchgears for Motor Control applications
•Engines – CAT 3516B – 1383KW/1854HP- ECM Controlled Engine and Alternator-1505KW
•Generators – KATO Engg. – 1505KW/2018HP with KCR760 Series Voltage Regulator and WoodWord 2301B Speed Control Module.
•Safety System – Fire/Smoke and Gas(H2S) Monitoring and Alarm Activation System (Make- Dragger Sys.)
•Public Address and General Alarm(PAGA) System.
•Entertainment (Television)
•Communication Systems – VHF/SSB Radio system / Internet Facility on Rig.
•SCADA system for ONGC office monitoring
•Rig Air Compressors – Make - Quincy
•Jacking System – AC motor controlled Drives (600VAC - 42KW each motor)
RESPONCIBILITES
•Inspect, Test, Adjust and Repairs Electric, Electronics, Mechanical, and Pneumatic Instruments and system used to indicate, record and control various operations.
•Inspect Meters, Indicators and Gauges to detect abnormal fluctuations.
•Knowledge on functioning of analog/ Digital/ Frequency type sensors including troubleshooting, repair and calibration
•Removes defective Instruments from System and Decontaminates as well as Dissembles and Cleans Instruments and Replaces defective Parts using Hand Tools
•Prepares schematic drawings, sketches, and reports to reflect changes or alterations made in instruments, circuits, and systems.
•Knowledge of proper design, construction and testing of Pressure, Rate, Density, Optical Encoder, CAT5, Coax, and Serial DB cables and connectors.
•Assembled complex electrical and electronic appliances such as control panels and Ex. rating lamps including Fluorescent lamps and Flood lamps.
•Getting all the technical details of engineers & Prepairs miscellaneous rig maintenance suing the service information system. Working on private rig like great ship, 4 Rigs ( Chetna, Chitra, Charu, Chaya )
•Transocian & ONGC as well as ONGC Plat Form at Mumbai High and Porbander ONGC.
PROJECT HANDLE IN PRABHAT POWERTECH PVT LTD. YEAR-2013
REALAINCE RECIVING SUBSTATION (GHATKOPER CHANDIVALI VILLAGE)
•Installation of incoming & outgoing Feeder piller,Panel Errection.
•installation & clubbing copper Basbar for all Feeder Panel.
•Installation of 66 kv step up Transformer, 33kv step down Transformer & 415V Distribution Transformer Testing,Commissioning of oil & Transformer winding at substation.
•Installation of addressable fire alarm Panel .
•Laying of fire alarm cable installation break glass, hooter & smoke detector.
•Imnstallation of perforated &ladder type tray for control &power cables for tranformer & panel.
•Installation of 10 HP Hydraulic & domestic pump panel, cable laying & termination
•Of dual starter & start delta starters.
•Installation all types of light fixtures.
•Installation of telecommunication & internet system
•installation of capacitor bank 24v DC battery bank for Feeder Panel.
•Other Troubleshooting of substation, Earting,lighting system light Fixtures.