RESU M E
Z ahid Ali
Objective: To pursue a career in a dynamic and well-reputed firm to apply my technical and
managerial skills in a challenging environment and contribute towards growth of the firm
JOB SU M M ARY
Having a 11 years experience in electrical fields and have been working in fertilizer plant since 2006
to now, have been performing the preventive and corrective and periodic maintenance of the
electrical machines and equipment according with electrical safety rules and regulation
Academic and I ndustrial T raining
Diploma of associate Engineering Electrical in 2004 from Lahore board of technical education
and got the 76% marks
Matriculation in science subjects attained the 74% marks from Bahawalpur board in 2001
Apprenticeship two years duration from Fauji fertilizer Company Mirpur Mathelo in 2006
P rofessional profile
Qatar fertilizer company sate of Qatar
Working as an Electrical Technician since 2011 to till
Performing the numerous maintenance task and responsible the following subject
Preventive corrective and periodic maintenance of electrical machines and switch gear
Equipment fault history and maintenance record logging in CMMS JD Edward
Plan the plant shut down activities and contract man power management
Handle the plant emergency activities and trouble shoot the faults
1
Ensure the all job has been done according to safety rules and regulation
Participate in monthly safety walk and audit the electrical installation
Fauji Fertilizer Company Mirpur Mathelo Pakistan
Worked in Fauji Fertilizer Company from 2006to 2011 as an Electrical Technician
Participated in cooling tower motor and switch gear replacement power and control
cables laying glanding and termination
Worked as shift Technician and responsible to handle electrical emergency on plant and
breaker isolation and inspection of Generator slip rings and carbon brushes
replacement
Worked as auxiliary fire fighter to control the emergency on plant
WOR K I N G E XPER I E NC E A N D S K I L LS
T RANSFOR M ER MA I N T E NANCE AND TEST I NG
Maintenance of transformer rating 55MVA, 66KV (AREVA, SIEMENS)
Power and control cables termination Sampling of oil, break down voltage test. Dissolving gas
analysis test and routine inspection of transformer
G ENERATOR AND M O TOR MA I N T E NANCE
Generator rating 46MVA(Brush made) routine inspection overhauling winding tests and
extraction of rotor and inspection of slip rings and replacement of carbon brushes
MV motors rating 3.2 MW(ABB.SCHORCH) maintenance bearing replacement rotor extraction
inspection and winding test PI and DAR
Termination box insulator, rotor bars and stator winding inspection
SUBSTA IO N SWI TC HGEAR AND BREAKER (ABB,MAGR I N I GALEL IO
A REAVA)
Maintenance of GIS switch gear(ABB) sf6 circuit breaker testing gas filling and checking of
closing and opening mechanism
Oil circuit breaker air circuit breaker and vacuum circuit breaker maintenance inspection
2
U PS PANEL (GUTOR, CEG) AND BATTER I ES (HOPPECK)
M A I N T E NANCE
Worked on UPS panel fault rectification and maintenance
Batteries bank maintenance gravity test and impedance test
F I RE DE TECT IO N, SUPPERS ION SYSTE M AND SIREN SYSTE M
Fire alarm panel fire detection devices smoke,heat, beam and flame detector (AUTRONICA
AND SIMPLEX)
Fire extinguisher system Inergen, Novec and Clean agent panel maintenance and fault
rectification
Public warning unit siren panel Sircom and Horman maintenance and logic designing and fault
rectification
M ISSELENOUS P LAN T JOBS
Maintenance of over head crane 35ton rating hoisting and cross moving motors brake
adjustment and pendent wiring
Worked on motor operated valve ROTORK made torque, opening and closing adjustment
Welding and lathe machines overhauling and fault rectification
Worked on variable speed devices ABB fault rectification and setting
Worked on plant cathode protection system
Relay testing equipment secondary current injection set
Low voltage cable jointing, glanding and termination
Inspection and testing of electrical devices overload relay circuit breaker and magnetic
contactor etc.
Inspection of electrical motors and brake adjustment of the ship loader
D IST I NCT I VE ROLE
Alignment and testing of Substation fire safety equipment beam detector, flame detector and
interfacing With plant fire alarm system
Audit of electrical power DBs and installation fault identification and prevention
3
Chemical store and ware house fire safety equipment aspiration detectors,flame detectors
and manual call points maintenance and trouble shooting
Transformer and long range conveyor belts fire safety thermo sensitive cable connection
inspection and trouble shooting
Performed the role of evacuation team leader during building fire coordinate with fire fighter
and assist about electrical installation isolation
I N D USTR IAL T RA I N I NG
Passed the EX equipment maintenance training (loughbourgh London)
Passed the MOVs maintenance training ROTORK
Plant safety and hazardous area and integrated HSEQ training
Work permit and lock out and tag procedure training
Attended the confined space entry and its hazard training
PE RSONAL D E TA I LS
NAME ZAH ID AL I
FATHER NAME MU HAM MAD HAN IF
MARTIAL MARRIED
STATUS
PASS PORT ZE1791322
CNIC 313**********
CONTACTS 009***********,009**********
EMAI L ZAH acym31@r.postjobfree.com
POSTAL FAUJI CLOTH HOUSE SANJARPUR TEHSILE
A DDRESS SADIQ ABAD
DISTRICT RAH I M YAR K HAN PUNJAB
COUNTRY VALID QATARI RESISDENCE PERMIT AND
STAY DRIVING L ICENSE
4
5