Sajjad Ali Mir

acvlwm@r.postjobfree.com

630-***-****

Objective: Highly motivated seeking a challenging full-time position in the HVAC & Plumbing Design engineering.

Work Experience:

Mechanical Design Engineer, AG Consulting Engineering.

New York NY10001 (Jan .2015 to Present):

Develop and coordinate the design of mechanical & Plumbing building systems.

Attend client meetings to develop MEP/FP scope of work and LEED objectives.

Prepare calculations for mechanical equipment sizing and selection.

Specify, schedule and layout mechanical air and water systems.

Write mechanical specifications.

Conduct site visits, review shop drawings, submittals and answer contractors RFIs.

Responsible for the delivery of projects on time and per clients requirement.

SUNY Stony Brook University, Design Services for West Apartmentss, Building J.

NYCHA Hammel Houses, Mechanical and plumbing design for the new boiler plant and the supporting plumbing work for the new

plant

NYCHA Hurricane Sandy Capital Improvement Program for Smith Houses, Design work on HVAC for the restoration

following damage done by Super storm sandy.

.Brockton VAMC laundry Building Renovation 38,000 square foot industrial laundry building washes 7 million pounds of cloth

per year design HVAC & Plumbing system. Mechanical designer in project involving new HVAC & Plumbing for a completely

gutted and renovated laundry facility. Prior to new project, facility consisted of only Heating and venting units and exhaust fans with

roof and wall openings as means of make-up air. For new project planned and designed new HVAC for office spaces, lounge, storage

rooms and areas of equipment floor where people are working. Heat recovery VRF system were designed to provide simultaneous

heating or cooling per room/zone need. Supplements heating thourghout the building attained by hot water unit heaters, baseboard

heaters and cabinet heaters.

CUNY City College Compton Goethals Hall Basement Renovation modified the existing HVAC supply, return and exhaust

ductwork to serve the new program.

Perry Point Potable water system Imporvements, Perry Point VAMC As a Mechanical Design Engineer worked on this 12,000

square foot critical water treatment facility.

Ohmsett Facility Sandy Repair - Sustainable Responsible for HVAC & Plumbing system involved in selection of Louvers, exhaust

fan, Unit heater Ejector Pumps.

Mechanical Design Engineer, General Energy Corp Chicago, IL

(Nov 2008 to Dec 2014):

Abu Dhabi National Oil Co (U.A.E), The 74 Story high rise building )4036 Tons Capacity project) Involved in Load Calculation

selection of Chiller, AHU FCU Duct design.

OHare Modernization Program: Projects involved providing new HVAC equipment in areas of building where new equipment

was being installed, or where existi ng AC in an area was insuffici ent and additional air conditioning was needed. After cooling load

calculation were performed, planned and designed the installation of split system and roof top unit

Canton Correction Center Fulton County Mechanical Designer responsible for Replace Hot Water Boiler Department of

Correction Six hot water boiler Capacity 520 MBH. Three Pumps capacity 78 GPM. (3) hot water recirc. Pumps & Hot water

storage tank.Gibsons Corporate office, Chicago, IL. Tenant build-out project-As a project manager investigated the site and did

analysis of feasible MEP/FP design.

Mechanical Design Engineer, Delta Engineering Inc:

Oct 2005 to Nov 2008

Illinois State Toll Highway Authority, IL Toll Plazas at Dixon & Dekalb ( Mechanical Construction Supervision) Made daily field

observation and progress reports, coordinated with HVAC, Plumbing, Electrical & Structural. Reviewed shop drawings (Mechanica l

& Plumbing system also coordinated with Architects the progress sta ges of the of the construction.

Chicago Housing Authority, IL Perlman Apartments.HVAC & Plumbing system involved in load calculation daily field

observation and progress reports, coordinated with HVAC, Plumbing, Electrical & Structural. Reviewed shop drawings (Mechanica l

& Plumbing system also coordinated with Architects the progress stages of the of the construction.

Mollison Elementary School Lead mechanical Design engineer responsible for updating the existing mechanical system.

This includes the field assessment design inspection of construction new A?C system for class rooms by installaing (2)

roof top unit work also involves design new boiler and hot water heaters and changing the existing Pneumatic controls.

Mechanical Design Engineer, McGuire Engineers Inc: Aug 1995 to Sept 2005

Field Museum (Collection Resource center) (Mechanical Designer & Construction Supervision) Made daily field observation and

progress reports, coordinated with HVAC, Plumbing, Electrical & Structural. Reviewed shop drawings (Mechanical & Plumbing

system also coordinated with Architects the progress stages of th e of the construction

Education

Bachelor of Science, Mechanical Engineering, Mehran University of Engineering and Technology Sindh 1986.

.

Computer Skills: AutoCAD 2015, Trace 700,Carrier E-20, Microsoft Office, Microsoft Excel

Ref: Gary Guleria President 212-***-****

John Clai (GEC) Director 630-***-****



Contact this candidate