Post Job Free

Resume

Sign in

Engineer Power

Location:
Bangalore, Karnataka, India
Posted:
July 19, 2019

Contact this candidate

Resume:

Name : ROMIT N. SHIRGUPPI

Mobile :+919*********

E-Mail : ac9uux@r.postjobfree.com

OBJECTIVE

To work with your organization that provides me an opportunity to improve my technical & communicational skills and knowledge to grow along with the organizational objectives

WORK EXPERIENCE

I have worked as a Trainee Automation Engineer at Biznustek Systems Pvt. Ltd. The job role includes programming the Delta PLC, Delta HMI, Delta VFD, EXOR HMI and the panel wiring for the machine.

I have programmed the PLC according to the requirements of the machine (AKVAZEN) for instance changing the frequency of operation according to the temperature variation automatically thereby the speed of motor changes.

The whole program for AKVAZEN was rebuilt by me where the length of the program was reduced drastically making it readable and more stable in terms of operation and error handling. The number of Inputs/Outputs used was reduced by new program hence few IOs could be used for backups thereby reducing the cost for additional modules.

EXOR HMI was used for IOT purpose where I have designed different graphs according to the daily requirements of the faculty. VFD parameters were set in a way that it displays power factor, input power, output current etc.

In panel wiring, the number of relay cards has been reduced by rewiring NC contacts of the existing relays which decreased the cost of 1 complete relay card. I have even prepared a panel board for automatic tank filling operation by ancient hardwired relay technology without PLC, Latching Relays or audino board by using simple relays.

I have provided a sound solution to the problem at IAMPL due to which our company saved the cost of a 7.5hp motor which was supposed to be replaced due to overheating.

Problem:-When AKVAZEN was running on UPS supply, after the duration of 1hr the motor was getting heated up and the temperature rise was up to 130degrees with a current input of 13A. This was not desirable for a safe operation because the motor winding gets damaged and core saturation takes place.

Solution: - There is a presence of harmonics in the power supply which might be either from the UPS or any other non linear loads. As a result of harmonic contents in the power supply the motor is getting heated up above the permissible value which reduces the efficiency and lifespan of motor. This was confirmed by IAMPL.

TRAINING UNDERGONE

Obtained Post Graduation Diploma In Industrial Automation (PGDIA) from Wartens Technologies LLP, Bangalore. I have completed this course by writing an exam conducted by the board of CTDS which is Govt. of India approved autonomous body with B+(above 70+) grade.

The training included practical exposure to the below components:-

PLC –Programming languages such as Ladder Diagram and Hands on practical exposure on software such as

Allen Bradley - Pico soft Omron - Zen support, CX Programmer

Keyence - KV Ladder Builder Schneider - Zelio soft, Twido Suite

Delta - WPL soft, IPsoft Mitsubishi - GX Developer

Wecon - Wecon PLC Editor ABB - CoDeSys

Siemens - S7-300, TIA Portal

SCADA – GE-IFIX, WONDERWARE INTOUCH

HMI – GP-PRO-EX, VT DESIGNER, SIEMENS WINCC

Electrical – Panel wiring & circuitry design.

Communication channel – RS-232, RS-422, RS- 485

INTERNSHIPS

Name of the Company : Karnataka Power Corporation, Ambikanagar

Duration of Internship : 15 days

Field of work : Generator Transformers and Control Systems

Name of the Company : The West Coast Paper Mills Ltd.

Duration of Internship : 15 days

Field of work : Electrical Systems such as PLC, VFD, motor drives etc.

Both the above internships have been completed with detailed report and certificates.

PROJECT WORK

Title: “Photovoltaic Solar System Evolution and Design”.

Description: The project explains about,

How the evolution of solar cell has taken place to date.

Factors affecting the performance of a solar cell using online simulators.

Design of a grid connected PV system manually and by using design software viz. PVSYST.

Factors affecting the performance of PV systems.

Impacts of connecting PV system to the grid.

PAPER PUBLISHED

A technical paper on “A Survey on the Evolution of Solar Cell Materials” is published in the “International Journal of Advance Research, Ideas and Innovations in Technology” on 5th July 2018.

Description: The paper explains about,

How the evolution of a solar cell has taken place to date.

Reasons for the enhanced efficiency of different types of solar cell materials used worldwide.

Different properties, advantages and disadvantages of PV materials used for manufacturing the solar panels.

ACADEMIC PROFILE

Year of Passing

Course

Institution/University

Percentage

2018

BE(EEE)

KLS, Gogte Institute of Technology, Belagavi.

65

2014

PUC

Bangur Nagar Junior College, Dandeli.

75

2012

SSLC

Janata Vidyalaya, Dandeli.

92

COMPUTER SKILLS

Packages : Microsoft Office. Excel

Design Software : PVSYST, Pspice, Matlab, Autocad

PERSONAL DETAILS

Date of Birth : 09-03-1996

Nationality : Indian

Marital Status : Single

Languages known : Kannada, English, Hindi and Marathi.

Address : H.No 522, Near CSI Church, Township, Dandeli (581325)

DECLARATION

I hereby declare that above mentioned information is true to the best of my knowledge and belief.

Date - 16/07/19 Romit Shirguppi

Place: - Bangalore



Contact this candidate