SANDEEP KUMAR ******************@*****.***
Bhandari Colony Block-A Subhash +91-909*******
Nagar Paniyala Road Roorkee 936-***-****
Pin Code-247667 District- Haridwar
State-Uttarakhand, India
MECHANICAL ENGINEERING PROFESSIONAL WITH 12 YEARS EXPERIENCE IN OPERATION AND MAINTENANCE OF HVAC SYSTEM, MEP SERVICES/FACILITY MANAGEMENT/ HVAC AND MEP PROJECTS
PROFESSIONAL SUMMARY
Engineering professional with 12 years with proven track record in facilities management, MEP services, HVAC(Refrigeration and air conditioning)/utilities/MEP services, projects, budget preparation and control, equipments efficiency improvements, KAIZEN,RCA, cost control, capacity planning, MIS, operating cost, relationship management, team management, coaching and mentoring, IR issues, general administration, Liaison with government authorities for various NOC renewals. Acquainted with systems & equipments such as screw, reciprocating and centrifugal chillers, Ammonia based refrigeration system, CRAC Units, Ductable Units etc. Well versed with Electric Panel, Control System, Air Circuit Breaker, Vacuums Circuit Breaker, and DG Sets, Transformer & UPS etc. Hands-on experience in implementing innovative ideas to reduce operational cost, energy consumption & improve efficiency of utility equipments.Capability in ensuring adherence of the overall process in accordance with internal and external quality guidelines as well as maintaining requisite documents, Possess team management, coordination and problem solving abilities.
EMPLOYMENT DETAILS
Shreya Life Sciences Pvt. Limited July 2007 - June 2009
Officer Engineering
Biological E Limited June 2009 - Nov 2011
Executive Engineering
Glenmark Pharmaceuticals Limited Nov 2011 - Oct 2012
Sr. Officer Engineering
Cadbury India Limited Oct 2012 - May 2014
Sr. Executive Engineering
Intas Pharmaceuticals Ltd May 2014 – Jan 2016
Sr. Executive Engineering
Sun Pharmaceutical Industries Ltd. Feb 2016 - Present
Manager Engineering
ACADEMIC AND PROFESSIONAL CREDENTIALS
B.E in Mechanical Engineering (regular) with 67 % marks in 2007 from Yagyavalkya institute of technology affiliated to university of Rajasthan
Intermediate with 55% marks from BSM Inter college Roorkee (Uttarakhand Board) in 2003
High school with 61% marks from BSM Inter College Roorkee (U.P Board) in 2000
CORE COMPETENCIES
Operation and maintenance of chiller up to 500 TR, ammonia based low temperature refrigeration plants up to 300 TR, Low temperature DX Plants up to 126 TR, Brine chillers up to 200 TR, hot water generation system, air compressor up to 575 CFM (reciprocating and screw), steam boilers up to 10000 Kg/Hr, FBC (coal fire), cooling towers, centrifuge, heat exchangers, tank farm, UPS 255 KVA, precision air conditioners, DG set up to 1500KVA, HVAC equipment, building management system(BMS), RO/DM plants, water treatment plant with ultra filtration of 25 M3/Hr, sewage treatment plant of 450 KLD, cold storage, deep freezers
Conceptualization and execution of retrofit projects with respect to building, MEP services, HVAC, electrical
Team leader with proven track record of coaching, mentoring
Project planning with management and execution of MEP services, HVAC equipments, clean utilities, pharma equipments, ETP, STP with the help of consultant and third party approved vendors
Responsible for Operation Maintenance & Servicing of Package unit, Ducted splits, VRV/VRF units up to 300 HP, FCU, AHU, Fire-Fighting equipments, Plumbing, HT/LT Panel, D.G Set, UPS system, exhaust fan, lifts, refrigeration units & pumps, supervising electrical distribution including transformers
Responsible for Maintenance of chilled water systems and attending breakdowns timely completion of activities to the specified standard & specifications
Highly experience in general repair and maintenance (HVAC, utilities, mechanical, electrical, plumbing, building maintenance), execute all interior and exterior building maintenance improvement projects from start to completion within the projected timelines and budgets, manage all special projects including utilities, HVAC, power, fire system, life & safety, active member of plant safety committee to lead on plant emergency response team
Annual budget preparation OPEX/CAPEX and monitoring & controlling maintenance costs, tendering for new annual maintenance contracts in timely manner
Monitoring with engineers, Supervisor’s & Technicians for smooth operation of facilities
Preparation and approval of procedures, SOP, yearly preventive maintenance schedule, leave schedule and approval of monthly invoices
Operation and maintenance of constant volume and variable volume low side HVAC system including 250 No’s AHU, 50 No’s ductable units, 50 No’s hanging units
NOTABLE ACCOMPLISHMENTS
100% up time of HVAC/utilities equipments, improved plant efficiency through best maintenance practices
Maintaining data centers designed room conditions within the specified limits through 100 % up time of air conditioning system by performing periodic, preventive maintenance and good maintenance practices
Worth Saving of 43 Lac/annum through condensate recovery project, 1.5 crore at steam boiler by minimizing the breakdowns, 50 Lac by improving chiller efficiency
Improved customer satisfaction 30% within nine months through re-engineering support processes with up gradation of existing system and providing technical training to support staff
Replacement of boiler chimney in the least time without any safety hazards, up gradation of HVAC system for a better quality of products and to improve plant efficiency
Driving the cost efficiency measures across stores, services, repairs (SSR), reduction of inventory by standardization of spares and indenting using SAP within budget allocation
Installation of AFD at water cooled chiller to get savings
Successful completion of four retrofit projects with respect to MEP, building, HVAC
PROFESSIONAL ENHANCEMENTS
Preparing CAPEX budgets as per requirements and controlling expenses, tracking expenses to control the budget within the specified limits
Ensuring safety of the HVAC/utilities section and compliance to regional and global EHS guidelines, ensuring quality assurance though engineering improvements on defect rates analysis (FMECA), root cause analysis
Successful Installation and commissioning of water cooled chillers, air cooled chillers, cooling towers, PAC system, DG sets, Chilled water system, BMS system, AHU, FCU, ductable units, DX units, ammonia refrigeration system, MEP services, plumbing services, water treatment plants, air compressors, VRV system
Successfully modifications of facility/ rooms as per business requirements
To prepare procedures/SOP and documents related to utilities/HVAC/Facilities
PROJECTS
Holds the merit for executing -MEP project, HVAC Project entailing installation of Chillers, pumps, ducts, cooling towers, piping system, Fire fighting system like wet riser, hydrant system,FAS system,FM200, NOVAC Inergen gas suppression system, AHU,CHW high wall and CHW cassette & deep bed dry Chemical Scrubbers, looked after crucial tasks which entails
Preparation of Due Diligence Reports/ Tender & RFP Documents/ BOQs/ HVAC Drawing/ Capital Expenditure Reports/ PERT Charts
Concept/Design discussions with the architects, preliminary planning based on architectural layouts
Co-ordination with architectural and structural & all MEP work, mobilizing manpower and materials at the site
Checking weekly and monthly project progress, regular follow up with consultant, reporting to the project head and regular inspection of the project sites
Checking and verification of HVAC, building, electrical, fire fighting & plumbing service layouts
Preparation of techno commercial comparison and feasibility study for upcoming projects
Supervising rigging, lifting and installing the equipment’s
COMPUTER SKILLS AND SOFTWARE USED
MS office, auto CAD, SAP, CMMS, Citrix, EDMS, CAFM, internet applications
LANGUAGES
Hindi - Native
English – Read, Write, Speak
PERSONAL DETAILS
Fathers Name: Mr. Satyapal Singh Marital Status: Married
DOB: July 30, 1985 Nationality: India
Gender: Male Passport No: T5631237 Expires 06/27/29
DECLARATION
I, Sandeep Kumar, hereby declare that the information contained herein is true and correct to the best of my knowledge and belief.
Sandeep Kumar