Post Job Free

Resume

Sign in

Electrical Engineer Power Plant

Location:
Toronto, ON, Canada
Salary:
75,000
Posted:
August 31, 2018

Contact this candidate

Resume:

Electrical Engineer, P.Eng

*** ****** ****,

Newmarket, ON, L3X 3G3

+1-416-***-****

ac6v1p@r.postjobfree.com

Objective:

I am looking for a position that gives me the opportunity to work with hardworking and likeminded professionals, united in the goal of adding value to the customers that make GTA such a thriving city.

Employment History

BLACK AND MCDONALD

Electrical Designer Contract

May 2017 – July 2017

Scarborough, CA

William Osler Health System Etobicoke General Hospital, patient care building

Oversee engineering consultant design drawings for the preliminary design and project construction including code compliance with healthcare standards and regulations.

Conduit size calculation based on number of wires at 40% conduit fill using three phase grounded systems theory for balanced loads in order to determine the number of neutrals.

Used the existing single line distribution diagram to determine the number of branch circuits considering the constraints related to patient care environment where neutrals are dedicated for each branch circuit in critical areas and the wiring of the essential electrical system shall be kept entirely independent. Using these criteria I realized that the conduit will be oversized because of the great number of bonding conductors. To solve this issue I recommend one bonding conductor only for each main distribution conduits with separate calculation.

NORR

Electrical Designer Contract

October 2016 – March 2017

Toronto, CA

Oversee engineering consultant design drawings for the preliminary design and project construction

Participate in the design and construction of the project - Building Code Compliance for Public Works & Government Services - Carling Campus – Ottawa

Responsible for design and project administration for Offices & Data Centers development - Ministry of Natural Resources - Peterborough

Perform compliance audits, design and construction for Casino Power Systems upgrades - OLG Slots at Mohawk

Managing the implementation, code compliance, and monitoring of the concept design Courthouses, Correctional Facilities & Office buildings PWGSC

MCGREGOR ALLSOP

Electrical Designer Contract

May 2015 – August 2015

Toronto, CA

Designed a lighting retrofit solution for RioCan Investment Inc for an underground parking

Prepare reports and input information and Cost Analysis Report which analyzed the best solution:, based on specifications and power saving calculations

Manage the measurement of construction progress and the preparation of payment certificates,

Provided field support and preventive maintenance analysis in building & industry engineering

Put together a tender package of documents that will aid the owner in the bidding process.

Performed site inspections, commissioning, and conduct efficiency tests to review contractor’s performance following the approved design and code compliance.

M&E

Electrical Designer Contract

September 2014 – May 2015

Toronto, CA

Involved in primary design including system selection, and implementation of building systems.

Performed building condition survey, formal compliance audits to identify property requirements to ensure environmental, codes and regulations compliance

Prepared Preventive Maintenance Analysis for HV/LV Power Distribution, Emergency Power and UPS, lighting and Emergency Lighting, Fire Alarm electrical equipment.

Provide field support by site inspections to solve any arising issues in preliminary design.

Engineering studies c/w investigation reports to identify and develop engineering design standards for buildings and manage the implementation of the approved design.

Conceptual design, design review and drafting for hotel and leisure facilities.

Tender services, Bid Price Analysis c/w accuracy of the financial information.

Review shop drawings and prepare specifications.

Issued Addendums, minor changes, Site Instructions and Change Notices

Construction monitoring, scheduling and commissioning.

ELLARD- WILSON

Electrical Designer

September 2013 – August 2014

Toronto, CA

Provided field support to solve any arising issues in preliminary design

Organized and performed engineering studies and investigation reports

Created conceptual designs, design reviews for schools in GTA.

Performed pre-tendering, tender services and id Price Analysis for schools in GTA

Review shop drawings and prepare specifications.

Responsible for construction monitoring, scheduling and commissioning

GENIVAR

Senior Electrical Designer

March 2008 – May 2013

Markham, CA

Target retail stores

Follow and establish planning cycle with detailed milestones for preliminary design and construction monitoring.

Designed and sized cables and conduits inside duct bank and submitted the CAD drawings to the Power Utility provider for a Construction Permit.

Performed Quality Assurance/Control and as well as Shop Drawings Review

Validated the design using the CSA standards and provincial regulations and the current safety and electrical standard (OSHA and OEC)

Prepared Engineering Analysis and Energy Management. Assisted the P.Eng. in performing Short Circuit Analysis.

Assisted in determining components based on price and functionality.

Commissioning: Review all documents required by Building Code for Occupancy Permit and performed final site inspection.

Provides technical guidance to Drafters, Designers, and lower-level Engineers working on the same project

Bell & Bell Mobility

Designed and sized cables and conduits inside duct bank and submitted the CAD drawings to the Power Utility

Carried out a Protective Device Coordination study validating the design of installation for HVAC equipment to improve air distribution system, power supply for new rectifiers, switchboard relief, UPS installation, stand-by generators, upgraded electrical systems and data centre upgrades

Identified critical loads, performed Load Study for power distribution system and standby generator.

Established the settings for protection in effort to minimize selectivity and maintain equipment longevity.

Provided a power supply design for Bell - DC Power Systems/Emerson rectifiers.

Overlooked the installation of new cooling systems as well as add redundancy .

Created drawings and specifications package using for the design and presented it to the Bell Project Managers.

Performed cost estimations in order to maintain a budget and offered designed options and drawbacks.

Active communication with Hydro, ESA, City and local authorities AHJ in order to allow for incremental updates.

Communicated with manufacturers and supliers, verified the work to abide to the design and safety code, identified deficiencies through site inspections, and delivered the project.

GENIVAR

Senior Electrical Designer

March 2008 – May 2013

Markham, CA

Municipality of Barrie – Water Treatment Plant

Provided an electrical designs for Municipal Infrastructure Facilities, carried out Power Systems Studies as well as Instrumentation and Control

Designed electrical layouts for incoming power distribution system and determined conduit size/length using Ontario Electrical Safety Code. Prepared the CAD drawings required for the design.

Assumed responsibility for any project assistance in construction (submitted through Request For Information) as well as mark down known deficiencies.

Provided an electrical designs for Municipal Infrastructure Facilities, carried out Power Systems Studies as well as Instrumentation and Control

Designed electrical layouts for incoming power distribution system and determined conduit size/length using Ontario Electrical Safety Code. Prepared the CAD drawings required for the design..

ABB

Electrical Designer Contract

September 2006 – March 2008

Markham, CA

HYDRO ONE project for DAM GATE CONTROL for TIMMINS

Designed, implemented and developed an OPG dam project for Gates Control for Power Plant in Timmins.

Created design diagrams for the Electrical Control Room for lifting and lowering the gates which control the power plant water flow, consisting of two 150kVA isolation transformers c/w NGR’s, distribution panels, splitters, and 400A disconnect switch.

Performed electrical load calculation, sized cables, voltage drops calculations and created cable schedules.

Added a 200A breaker for UPS and Emergency Generator. The breaker had mechanical interlock between main power supply and UPS for safety.

Electrical room was designed for two gates and controlled by a Schneider Electric Modicon Quantum PLC with Analog /Digital Inputs & Outputs

Followed design specifications, Ontario Electrical Code, OPG requirements, safety procedures and quality assurance procedures.

ZEREM ELECTRICAL

Electrical Supervisor

January 2001 – January 2008

Toronto, CA

Fido, Microcell - Radio communication antennas

Installed power supply for rectifiers for back-up battery on top of hi-rise buildings for wireless signal providers.

High Park Condominium - Toronto

Installed fire alarm system, gas detection systems, fire alarm cabling (class-A, single stage addressable), sprinkler supervisory system (shutoff valves, flow and pressure switches and master elevator intercom)

AIDS Children’s Hospital – Toronto

Successfully acquired ownership of the project for Zerem for a low cost in comparison to competing contractors Kept the management up to date with any obstacles and delays that we experienced.

Supervised the implementation of low voltage distribution, grounding, lighting, fire alarm and security system.

Verified that the work was meticulously done and abided to the OEC and safety requirements.

Organized the commissioning and made sure that all requirements were met at delivery time. Verified that the electrical design was correctly implemented according to the drawings and mark up as-build drawings.

Communicated with power and telephone companies to arrange hook-up to the building. Worked closely with the client, peers and other disciplines involved to avoid any work conflicts.

National Defence, Canadian Forces Base

Assigned resources, divided tasks based on time frames, controlled daily operations based on schedule and monitored progress.

Prepared contracts and negotiated revision changes based on obstacles.

Supervised the implementation of “Access CTRL /Security /CCTV”, Edwards Security Systems, Security Control Units, Remote Modules (RRE-Remote Reader Electronics) and Remote Relay Module (RIM-Remote Input Module)

Knowledge about in-house software applications to be used for resource management and ensure accuracy of financial information for timely and accurate payment of project contractors and other suppliers

Reviews drawing submittals perform technical bid analyses, and issues specifications.

Education

Gheorghe Asachi University

Iasi, Romania

Electrical Engineering

Power Systems

September 1982 – June 1987

Accreditations:

2001 - 309 Constructions and Maintenance Electrician

2003 – George Brown College – Allen Bradley PLC Technician

2016 – Professional Engineers Confirmatory Exam

2017 – Professional Engineering License

Constantin Amariutei

Electrical Engineer

P.Eng License - application (#100199687)



Contact this candidate