Page * of *

CURRICULUM VITAE

Personel mob: +919********* / +917*********.

PERSONAL DETAILS:- e-mail : ************@*****.*** SARAVANAKUMAR.A

Date of Birth : 07-06-1983

Nationality : Indian

Sex : Male

Marital Status : Married

Blood Group : B +ve

Languages Known:

English, Tamil and Hindi.

Passport Details:

Passport No. : P7346371.

Valid up to : 15.02.2027.

Issued at : Chennai.

Permanent Address:

No : 160 / 1, T.K.M.Road,

Vallam Post,

Chengalpattu.

Tamil Nadu-603 002. India.

Mobile-Res: +917*********.

Present Company:

M/s.Dhawin Engineering.

Sr.Electrical Testing & Commissioning

Engineer.

Previous Company:

1. M/s.Larson And Toubro LTD.

(Jan 2012 to Oct 2016)

2. M/s.Sterling and Wilson Ltd.

(Nov 2009 to Jan 2012)

3. M/s.SSEngineering – Sr.T&C

Engineer.

(March 2008 to Oct 2009)

4. M/s.Voltech Engineers Pvt Ltd.

(March 2006 to Jan 2008)

5. TNEB – 230KV/110KV SS

(GRT) Graduate Apprentice

Trainee. (March 2005 to Feb 2006)

Objective:

Professional carrier in your concern which offers continuous development opportunity and to draw satisfaction from personnel and organization growth.

Professional Details:

Professional Qualification:

Bachelor of Electrical and Electronics Engineering. Institute : Arulmigu Meenakshi Amman College of

engineering.

University : Madras University

Year of completion : 2004.

HIGHLIGHTS:

Carrying the job to the customer’s standard with safety and initiative’s creativity, communication & achieving the work at stipulate time.

Experience:

Having around 10 Years of experience and knowledge in the field of Electrical Testing & Commissioning and Maintenance of Protective Relays, Switchyards, Power Transformers, substations and power plants and Co-ordination of SCADA. Graduate Traine:

Tamil Nadu Eletricity Board (TNEB) – 230KV,110KV

Substation Grid Relay Testing (GRT).

Page 2 of 5

RESPONSIBILITIES IN EXECUTION OF PROJECTS :-

• Testing & Commissioning of Electrical Equipments (Switchyard - PowerTransformers, Generators, CT, CB, Disconnectors, Earth switches and Protective Relays).

• Scheme checks and Relay co-ordination as per specification.

• Preparation of safety documents and method of statements for outages.

• Preparation of As built drawings, cable schedule and Site acceptance test records according to the specifications.

• Trouble shooting of all Electrical control and protection circuits.

• BUS Transfer (BTS) System Testing and Commissioning. NATURE OF WORK :-

• Testing and commissioning of all Electrical equipment from 415volts Systems and 230KV & 400KV Substation.

• Testing, Diff Stability and REF Stability of Power Transformer (270MVA) .

• Testing and commissioning of L.T, MV, H.T Switchgears, Switchyard (CT, CVT, CB, Busbar, Disconnector, Earth switch).

• Testing and commissioning of Control & Protection panel and Protective Relays (Numerical- Areva, ABB, Siemens and, Electromagnetic)

• Transformer, Generator, and Motor Protection relays (Differential, Over current & Earth fault, REF and Stability and schemes .

• Inspection of control and relay panel, preparation of Test Report, cable schedule, As built Drawings, Method of statement for shutdown jobs and Operation & Maintenance for sub-station, power plant, and process plant.

PRESENT PROJECTS :-

1. Magagenco Thermal Power Project 3x660MW Tpp – Koradi.

• 400KV Switch yard Equipment testing and commissioning.

• Testing & commissioning of 11KV / 3.3KV / 0.433KV Switch gear Panels (500 Panel – C&S), Transformers (2.5MVA), Areva Relays, Protection Schematic and Operations,

• Preparation of contract completion documents for technical support.

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel.

• 330MVA G.T – Testing and Commissioning work.

• 63MVA ST – Testing and Commissioning work.

Page 3 of 5

• 20MVA UAT – Testing and commissioning work.

• BUS Transfer (BTS) System Testing and Commissioning. 2. Indiabulls Thermal Power Project 5x270MW Tpp – Nashik.

• 400KV Switch yard Equipment testing and commissioning.

• Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (300 Panel – L&T), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

• Preparation of contract completion documents for technical support.

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel.

• 330MVA G.T – Testing and Commissioning work.

• 63MVA ST – Testing and Commissioning work.

• 20MVA UAT – Testing and commissioning work.

• BUS Transfer (BTS) System Testing and Commissioning. 3. Rattan india Thermal Power Project 5x270MW Tpp – Amravati.

• 400KV Switch yard Equipment testing and commissioning.

• Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (100 Panel – L&T), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

• Preparation of contract completion documents for technical support.

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel.

• 330MVA G.T – Testing and Commissioning work.

• 63MVA ST – Testing and Commissioning work.

• 20MVA UAT – Testing and commissioning work.

• BUS Transfer (BTS) System Testing and Commissioning. 4. RAMANUJAR IT PARK.

Client : Alliance 1st. Projects : for EIL.

• 110KV Switch yard Equipment testing and commissioning.

• Testing & commissioning of 11KV / 0.433KV Switch gear Panels (4 Panel – Siemens), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

• Preparation of contract completion documents for technical support.

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel. Page 4 of 5

5. CHEYYAR SEZ DEVELOPERS.

Client : CSD. Projects : for EIL.

• Testing & commissioning of 11KV / 0.433KV Switch gear Panels (3 Panel – Siemens), Transformers (2.5MVA), AREVA Relays, Protection Schematic and Operations,

• Preparation of contract completion documents for technical support.

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel. 6. ISRO - THIRUVANDRAM.

Client : ISRO - SPCL. Projects : for EIL.

• Testing & commissioning of 11KV / 0.433KV Switch gear, Transformers (2.5MVA), AREVA, E.R Relays, Protection Schematic and Operations of Panels Phase -1,

• Preparation of Method of statement and safety document to the outages.

• Preparation of As built drawings and cable schedules for approvel. INTERNATIONAL ASSIGNMENT

OIL AND GAS :-

1. QATAR GAS.

Client : QATAR Electricity Board.

Projects : QATAR GAS - Raslaffan.

Testing and commissioning of 0.433KV Breaker (OC/ EF) Protection ABB Relay. – QATAR. DOMESTIC ASSIGNMENT

OIL AND GAS :-

• Testing and commissioning of 11KV / 0.433KV SWITCH GEAR, for 2.5MVA, 11KV 12MW SW Generator.Cordination with relay engineer for testing of ABB relays and Woodward Relays.

• Testing and commissioning of 0.433KV, 11KV SWITCH GEAR, 2.5 MVA Transformer.Cordination with relay engineer for testing of L&T relays.

POWER PLANT, SWITCHYARD, PROCESS PLANTS & SUB STATIONS :-

• Testing and commissioning of 3333KKVV AANNDD 1111KKVV SSWWIITTCCHH YYAARRDD, 50MVATransformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel Schemes,Relays (SIEMENS). COCHIN SHIP YARD thro Siemens.

• Testing and commissioning of 11KV SWITCH YARD, 50MVA Transformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & protection Schemes, Relays(ABB, Siemens).Motorla thro GET.

Page 5 of 5

• Testing and commissioning of 132/11 KV/0.433KV SWITCH YARD, 50MVA Transformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel Schemes,(ER Relays). PGCL – YANAM (A.P).

• Testing and commissioning of 0.433KV and 11kv Switchgear, Stability for Transformer 2.5MVA, Auxiliary protections, Control & protection Schemes, Relays(ABB). RAYALSEMA Thermal power plant – RAYALSEMA – A.P thro ABB.

• Testing and commissioning of 400KV/ 6.6KV G.T & S.T Transformer Commissioning and 6.6KV & 415V Switchgear, Stability for Transformer 2.5MVA, Auxiliary protections, Control

& protection Schemes, Relays(ABB). Indiabulls Thermal power plant – Amravati & Nasik. Experience with AREVA RELAYS

MiCOM P632 - Transformer Protection

MiCOM P120,P121,P111,P122 - O/C & E/F Protection

MiCOM P220 - Motor protection

CDG,CAG - Current operated relays

MVAJ, MVAX, MVTT, MVTU - Voltage Operated relays

Experience with ABB Relays

RET 670 - Transformer Diff.Protection.

SPAJ - O/C & E/F Protection.

SPAM and REM - Motor protection.

SPAU - U/V and O/V relay.

SPAJ 115c - SEF and REF.

Experience with SIEMENS Relays

7SJ6005, 7SJ6225 - O/C & E/F Protection.

7UT612 - Transofrmer Diff.Protection.

7SJ62,63,64 - Multi function Relay

SEL Relay - O/C & E/F Protection.

Regards,

SARAVANAKUMAR.A



Contact this candidate