Post Job Free
Sign in

Plant Power

Location:
Chennai, Tamil Nadu, India
Salary:
45000
Posted:
July 16, 2018

Contact this candidate

Resume:

SATHYAMOORTHY.M

:***********@*****.***

: 078********

:088********

: No. 6/86 Kovalan kadu, konganapuram(via)

Edippadi(Tk) Salem(Dt),

Tamil Nadu-637201.

PERSONAL DATA:-

Date of Birth :15thApril1987

Sex : Male

Nationality : Indian

Marital Status : Married

Languages known: English & Hindi Tamil

HOBBIES:-

Listening Music,

Reading News Paper,

Playing Cricket,

Net Surfing,

EXPERIENCE:-

7.5 years

DECLARATION:-

I am a person with strong interpersonal skills with ability to work in a team with diverse backgrounds. Additionally, I have strong commitment to quality, determination, dedication and discipline. Willing to learn and adapt to new opportunities and challenges. I hereby declare that the information furnished above is true to best of my knowledge.

OBJECTIVE:

To secure a position which would enable me to enhance my skills and challenge my abilities. I aim to achieve success through smart work and dedication and would like to make a career in an organization, which encourages learning, rewards achievements, provide job satisfaction and further potential for growth.

EXPERIENCE:

Presently working as a Senior commissioning engineer with Aqua Designs(I)Ltd. In Chennai

1.0 years working as a Process In charge with Ion Exchange India Ltd. in RO Plant of 540m3/hr capacity at Essar Refinery Jamnagar, Gujarat.

2.0 years Experience as a Shift In charge with M/S Font us Water Pvt Ltd. in RO based SEA WATER plant of 47MLD capacity at Adani Power plant Site Mundra-Gujarat.

2.0 year experience as a Process In charge with M/s Vetch Wabag Ltd. In RO Plant of 540m3/hr capacity at Essar Refinery Jamnagar, Gujarat.

2.0 year experience as a Shift in charge With M/S Diplex Water Engineering India Pvt Ltd.in UF-RO based DM&CPU Plant of 450m3/hr&100m3/hr Capacity at Bharat Oman Refinery Bina Madhya Pradesh.

1 year experienced as a Chemist cum Operator with ENMAS Power O&M Pvt. Ltd. In UF&RO based of DM Plant of 50m3/hr capacity at star metallic & Power Pvt. Hosbet Karnataka.

EDUCATIONAL QUALIFICATION:

Technical Qualification:

M.Sc. (General-chemistry) from karpagam Arts and science College Bharathiyer University, Coimbatore, Tamil Nadu in 2010 with 78%.

Academic Qualifications:

B.Sc. (Chemistry) from Senguthar Arts& Science College, Peryair University, Tamil Nadu in 2007 with 60%.

Higher Secondary from Tamil Nadu Board, Chennai in 2004 with 65%

STRENGTHS:

Dedicated towards my aim committed, punctual confident, disciplined, leadership qualities and also obedient when working as a subordinate.

CURRICULAR ACTIVITIES:

Sound knowledge of MS Office, MS Excel, MS Power Point and Internet

I have got Top position in my Graduation Level.

I have got first prize in Science quiz and Art competitions.

Successfully completed NSS program of two years during B.Sc.

Organizational and Promotional work in educational fairs.

COMPANY PROFILE & JOB RESPONSIBILTY:

1)M/s AQUA DESIGNS(I)LTD 26st DEC 016TOTill Date

POSITION : Senior Commissioning Eng.

PROJECT : 1. TTP-RO plant in IOCL-Barauni-Completed commissioning with in 3 month

ROunit-600 M3in per hour

2. DM-Plant in IOCL –Mathura-completed commissioning with in 1month capacity plant:200m3/hr

3.RO plant IN NTP-Assam-completed commissioning with in 1.5 month plant capacity-80m3/hr

1)M/s ION EXCHANGE (I)PVTLTD 10st JAN 016TO25th DEC

POSITION : PROCESS- in charge.

PROJECT : TTP-RO plant.

CLIENT : ESSAR OIL LTD, Gujarat, India.

Plant capacity : ROunit-540M3in per hour

Role & Responsibility:-

Managing all operation of 12.96MLD TTP-RO.

Trouble shooting of all types of process Monitoring plant and operation

Ensure smooth operation of ROplant and safety at the work place.

Prepare & implement all Operation Lab & Chemical SOP’s.

Managing all requirements of lab chemicals & bulk chemicals etc.

Look after PM work, RO Cleaning & UF CEB etc.

Responsible for preparation and submission of daily progress & Monthly report to the superiors.

All the operations, treatments and other works were being done under 5S Measures.

Complete operation of UF and RO Within the limits of its standard parameter.

Preparation of standard chemicals and Deviation Graphs for testing accuracy.

Recognize and solve problems and abnormalities of operation side.

Take corrective and preventive measures in case of deviations.

Reporting in Plant manager.

2)M/S FONTUS WATER PVTLTD 15 st APR 014TO 31st DEC 016

POSITION : Shift- in charge.

PROJECT : Desalination-RO plant.

CLIENT : ADANI POWER PVT, Gujarat, India.

Plant capacity : ROunit-47MLD in per hour

Role & Responsibility:-

Managing all operation of 47MLD Desalination-RO.

Complete operation of PT and RO Within the limits of its standard parameter.

Responsible for preparation and submission of daily progress & Monthly report to the superiors.

Responsible for preparation and Separate Work Permit of Maintained dept and supervision of work.

Contact & convenes other agencies to work with us on contact basis.

Qualitative and quantitative analysis of all types of materials.

Monitoring all production & quality activities in shift wise.

Identify hazards and their controls.

Maintaining all related documents and records of Operation in shift wise.

Trouble shooting of all types of process Monitoring plant and operation.

Reporting in production manager

3)M/s VATECH WABAG LTD 7st July 2012 TO20st may2014

POSITION : process in charge.

PROJECT : RO plant.

CLIENT : ESSAR OIL LTD, Gujarat, India.

Plant capacity : ROunit-540M3in per hour(commission and Operation take O&M)

Role & Responsibility:-

Managing all operation of 12.96MLD TTP-RO.

Trouble shooting of all types of process Monitoring plant and operation

Ensure smooth operation of ROplant and safety at the work place.

Prepare & implement all Operation Lab & Chemical SOP’s.

Managing all requirements of lab chemicals & bulk chemicals etc.

Look after PM work,RO Cleaning & UF CEB etc.

Responsible for preparation and submission of daily progress & Monthly report to the superiors.

All the operations, treatments and other works were being done under 5S Measures.

Complete operation of UF and RO Within the limits of its standard parameter.

Preparation of standard chemicals and Deviation Graphs for testing accuracy.

Recognize and solve problems and abnormalities Of operation side.

Take corrective and preventive measures in case of deviations.

Reporting in Plant manager.

4)M/s DIPLEX WATER ENGINEERINGINDIA PVT LTD

12th May 2010 to 25th Jun 2012

POSITION : shift in charge.

PROJECT : RO_DM Plant.

CLIENT : BHARATH OMAN REFINERIES LTD, Madhya Pradesh, India.

Plant Capacity : RO_DM UNIT-900M3 in per hour(commission and Operation take O&M)

Role & Responsibility:-

Managing all operation of 900 RO-DMPlant.

Handling of Refinery waste water Pre-treatment plant (Flash mixer, Flocculate Dissolved Air Floatation(DAF))

Controlling of whole Captive Power Plant(CPP), Refinery water consumption

Monitoring and maintenance for Raw water, ETP treated water, Cooling Tower Blow down from CPP & Refinery. (PH, FRC, COND, TDS, SIO2, OIL&GREASE, TSS, Fe, etc

Whole plant is operated by Auto Mode ( PLC, DCS)

Handling of Neutralization pit, equalizer pond (UF, RO Reject & Whole Plant Waste)

Trouble shooting of all types of process Monitoring plant and operation

Prepare & implement all Operation Lab & Chemical SOP’s.

Managing all requirements of lab chemicals & bulk chemicals etc.

Complete operation of UF/RO and CPU Plant/MB Within the limits of its standard parameter.

Reporting in Plant manager.

5) M/s ENMAS POWER PRIVATE ITD, TAMIL NADU India. 6th May 2007 to 14th May2008

POSITION : Operator cum Chemist.

PROJECT’s :Operation Maintenance of RO-DM.

CLIENT’s :

(1) 32MW Star Metallic and power pvt ltd, hospet, karanatka (40 m3 in DM plant).

(2)10MW Hotthur Steels and pvt ltd, Bellary, Karnataka (27m3inRODM plant).

(3)2*30MWUttamcalvaSteels, khopoli, Mumbai (150m3in RO DM plant).

Role & Responsibility:-

Managing all operation of 150m3 RO-DMPlant.

Continues Analyzing of each Parameter in plant.

Maintains of parameters of Boiler (PH, SILICA, PHOSPHATE) etc.

LAB ANALYSIS:

PH,Conductivity,Silica,phosphate,Hardhess,Chloride,Alkalinity,TDS,

Oil&Grease, Turbidity, Sulphur, SDI, FRC.

Coal Analysis of Inherent Moisture, Surface Moisture, Volatile Matter, Gcv, Fixed carbon, Total carbon,

LAB EQUIPMENTS:

Bomb Calorimeter, Furnace, Air Dryer, Spectrophotometer, PH-meter, Conductivity meter, Turbidity meter,

Whole plant is operated by Auto Mode ( PLC, DCS)

Handling of Neutralization pit, equalizer pond (UF, RO Reject & Whole Plant Waste)

Trouble shooting of all types of process Monitoring plant and operation

Prepare & implement all Operation Lab & Chemical SOP’s.

Managing all requirements of lab chemicals & bulk chemicals etc.

Complete operation of UF/RO and SAC/SBA/MB Within the limits of its standard parameter.

Reporting in Plant Chief Chemist.

TECHNICAL PROFICIENCY:

TYPE OF PLANTS : RO Plant, DM Plant, CPU Plant, TTP Plant, PERTERTMENT

Plant.

HANDLING EQUIPMENTS IN PLANT: MGF, DMF,PSF,ACF.CMF,MCF,BASKET

STRAINER,SAC,SBA,MB,UF,RO,DGTOWER,COOLINGTOWER

TROUBLE SHOOTING IN PLANT : RO Membrane Increasing of Biofouling&scaling,

Increasing feed pressure, Increasing Conductivity.

UF Membrane Increasing of TMP Biofouling&Scaling and Not getting SDI

Increasing Differential Pressure of All Filters.

Increasing Parameters of Mixed bed.

SATHYAMOORTHY.M

Date:

Place: Jamnagar Gujarat



Contact this candidate