SYNOPSIS
Young, energetic and result oriented professional with 9.6Years of experience; strong academic background; Extended expertise in Operation of thermal power plant
1.Dedicated and highly ambitious to achieve personal goals as well as the organizational goals
2.Friendly with an upbeat attitude
3.Excellent decision making skills with a positive approach
WORK EXPERIENCE
WORK AS A SIMER INFRASTRUCTURE LTD. EMPLOYEE AT TSPL (Vedanta) WORKS. At Mansa, Banawali (Punjab) (660*3MW) (Boiler 1st class operator) 16AUG 2014 To till date
Job Description:
4.Responsible for the smooth operation of PF Super critical boiler (2140TPH) of Harbin chain company
5.Handling field operation of boilers 2140TPH of Harbin chain (PF boiler), Compounded with China makes Three cylinders type Turbine with Four Exhaust steam condense.
6.Cold Start up, Hot Start-up, Warm start up, Normal Operation, Emergency Handling and Safe shut down of Units.
7.Line up of the unit and its auxiliaries, Change-over of equipments, routine testing of protection system and annunciation system.
8.Issue and cancellation PTW (Permit to Work) system, safe isolation, personnel safety and equipment safety.
9.Monitoring plant operations and handle emergencies including shut-down of units and load throw-off to control generation as per requirement.
10.Instruction to Field operators for safe operation of Power Plant
JOB PROFILE
SHUTDOWN ACTIVITIES
11.Checking & Testing of ID, FD and PA Fan .Monitoring bearing temperature and vibration, Motor and
Fan Lubrication system.
12.Checking of all the Motorized Operated Valve and Pneumatic Valve from the PLC and Field by getting their proper feedback.
13.Effectively coordinating with the supervisors and helpers during the test activities.
OPERATION
14.Routine check - up of all the drives and auxiliaries.
15.Preparing Shift Reports, Daily Generation Reports
16.Identifying the problems in the field and taking corrective actions.
EDUCATION
17.First Class Boiler Attendant Certificate From Dhanbad Jharkhand Board. (2014)
18.Second Class Boiler Attendant Certificate From Maharashtra Board. (2011) 19.XI from BSEB Board of Secondary Education.(2001)
20 . ITI (Industrial training Institute) Pass a trade of fitter in 2003.
PREVIOUS EXPERIENCE
1FROM 25 may 2013 TO AUG.10TH 2014 in Enmas energy ltd. M/S Finolex industries ltd. (Maharashtra). Thermal power plant 43 MW and Boiler field Operator THERMAL POWER PLANT Work. Boiler Capacity 110*2TPH, boiler type - AFBC (CVL)make water Tube Boiler
●FROM JAN. 2012 TO MAY 20TH 2013 in Feedback power. PVT LTD. M/S Transtech power Pvt. ltd sanchor (raj) Thermal power plant .12 MW & 2ndClass Boiler Operator THERMAL POWER PLANT Work. Boiler Capacity 55 TPH.
●FROM Jan.2008 to DEC.2011 in SANGAM POWER PLANT LTD. (BHILWARA) As ASST.Boiler OPERATOR 12 MW THERMAL POWER PLANT Work. Boiler Capacity 48TPH . Boiler Type- AFBC.
PERSONAL DETAILS
Date of Birth : 20/Jan./1986
Languages : English & Hindi.
Marital status : married
Nationality : Indian
DECLARATION
The above furnished information is true to best of my knowledge.