RESUME
L.Uma Parvathy Mob no: 959-***-****
B.E. (EEE) Mail id: ac2556@r.postjobfree.com
Profile Snapshot
Around 3 Years of Electrical Experience in the areas of Operations & Maintenance and Erection, T&C in Thermal Power Plant (BTG).
Implementation of Power System studies using ETAP. Value Addition
Certified ETAP Professional.
Professional Experience
Organization: Coastal Energen Pvt Ltd,
2*600MW Mutiara Thermal Power Plant.
Duration : May 2014 – Present.
Designation : Assistant Engineer.
Job Function
ETAP Exposure
Load flow Studies, Voltage Dip / Drop Studies.
Power factor correction studies at MV & LV Systems.
Reactive power Compensation studies in HV Systems.
Short-circuit Studies as per IEC 60909 & ANSI.
Static and Dynamic Motor Acceleration Studies.
Basics of Transient Stability – Angular Stability, Voltage Stability.
Overcurrent and Earth fault Relay coordination as per IEEE 242.
Arc flash studies as per IEEE 1584.
Equipment Sizing - Cable sizing, CT Sizing, Capacitor Sizing.
Implementation of Load flow studies, Short circuit studies, Relay Coordination and motor starting characteristics.
Erection and Commissioning
Testing and commissioning of Single and three Phase Power transformers upto 250 MVA.
Testing and commissioning of Generator Circuit breaker.
Testing and commissioning of Dry Type Transformers 2500 KVA.
Testing of SPBD and IPBD.
Testing and commissioning of MV Switchgears 11kV& 6.6kV.
Testing and commissioning of control & relay panel for Generator, Transformer.
Testing and commissioning of power control centre and motor control centre.
Testing of Protective Relays using Omicron CMC.
Hands on Experience in PCM 600.
Commissioning of ‘TRIP LOGIC MATRIX’ of BTG plant.
Trouble shooting of all Electrical circuits, control and protection circuits.
Commissioning of Fast Bus and Slow Bus Transfer systems. Operation and Maintenance
Primarily having experience on Troubleshooting of Motors, Preventive, Breakdown, Corrective Maintenance and Operation of Switchgear Feeders & MCC Panels and Motors (LT & HT).
Maintenance of 400/20 KV, 20/11KV, 11/6.6 KV Core type Power Transformers.
Maintenance of 11 KV/415 V Indoor type Power Transformers.
Maintenance and Operation of Starters (D.O.L, R.D.O.L).
Maintenance of Diesel Generator, DCDB systems & UPS systems.
Maintenance of ACB & VCB Breakers and Line CT’s & PT.
Maintenance of Control and Relay panels, HT and LT panels, Marshaling box.
Maintenance of MV and LV drives and switchgears.
Knowledge about coordination of Relays.
Preparation of Condition monitoring and Preventive Maintenance Schedule and report.
Analysis of fault and report preparation in BTG area.
Calculation of auxiliary power consumption.
Experience with ABB Relays
RET 670 - Transformer Protection relay
REM 610 - Motor Protection relay
REU 610, REU 615 - Voltage Protection
REF 610, REF 615 - Feeder Protection
SPAJ-140C - O/C & E/F Relay
Academic Qualification
B.E. in Electrical and Electronics Engineering with an aggregate of 8.38 (CGPA) from Chandy College of Engineering, Thoothukudi.
HSC with 85.25% from St.Aloysius Girls’ Higher Secondary School in Tamil Nadu State Board at Thoothukudi
SSLC with 90.2% from St.Aloysius Girls’ Higher Secondary School in Tamil Nadu State Board at Thoothukudi.
.
Personal Details:
Name - L.UMA PARVATHY
Father’s Name: - P.Lakshmi Kanthan
Address: - 77C, V.M. Kovil Street,
Thoothukudi 628002.
Date of Birth - 05-01-1993
Nationality - Indian
Marital Status - Single
Languages known - Tamil, English
Declaration
I hereby declare that the details furnished above are true to the best of my knowledge. Place: Signature
Date: [L.Uma Parvathy]