Village Garhi Jhanjara, P. O Ganaur,

Distt. Sonepat. (Haryana).

Pin Code - 131101.

Phone No. 013*-*******

PARVEEN KUMAR

Mobile no.+91-971*******

E Mail. : ********@*****.**.**

Objective:

To carry on my passion for renewable energy by working as Electrical Engineer and

Renewable Energy Analyst in a group of highly skilled individuals dedicated to developing the

next generation of solar energy.

Summary of Skills

Engineering Design: System Design of Solar Photovoltaic Power Projects (Grid

connected and off grid) and hybrid system, Develops and Designs Electrical

schematics, array layout, single-line diagrams, Feasibility Study Report, Detailed

Project Report, Energy Output Estimation, Shadow Analysis, Selection and sizing of

cable, fuses, MCB, battery, charge controller, inverters, lightning protection,

earthing/grounding and surge protection devices.

Expertise in Photovoltaic System: In depth understanding of solar photovoltaic

cells, module and Balance of System, Site Survey and Planning, System Sizing,

Develop Operation and Maintenance manuals, Quality Management System, Safety.

R&D: Research & Development activities in solar Photovoltaic. Performance Analysis

of solar PV system. Detailed analysis of Yield Assessments of solar farms, Comparison

of different technologies of PV modules, performance analysis of solar farms with

different tracking systems. Implementing different methods to improve efficiency and

reliability of system and analyze and review the study results.

System Design Software: PV Syst, PV Sol, PVdesignPro, Solar Advisory Model

(SAM), Solmetric SunEye (for Shadow Analysis), RET Screen, Homer, Meteonorm

(solar radiation Software), SolarGIS, 3 Tier etc.

PV Standards: Knowledge of IEC and NEC standards related to Solar Photovoltaic

designing and installation.

Module & Inverter Technology: Understanding of different solar module

technologies and on-grid inverters. Technical comparison of modules and inverter

technologies. Plant performance with string and central inverter in MW level plant.

Work Experiences :

Experience at Lanco Solar Pvt. Ltd.

I am working as Assistant Manager-Technology in Lanco Solar from 1st

June, 2010.

Preparation of Yield Energy Assessment reports for solar farms from

different data resources and simulation software’s.

Solar radiation and weather data resource assessment for India as well

as for international sites of Lanco Solar.

Site pre-feasibility report preparation based on local site conditions.

Module Technology and structure optimization based on site local

weather parameters.

Site Typical Mean Year (TMY) preparation with available satellite and

measured weather data.

Solar farms production analysis based on measured radiation data and plant

string monitoring data.

Monitoring performance of installed SPV system and timely prepares and

present performance analysis reports to Top Management.

Yield Estimation reports and Annual Performance Report for Grid

Connected Solar farms.

Shading analysis for solar power plants including far shading, inter-row

shading, building shading etc. using simulation software’s.

Solar photovoltaic module degradation calculation and analysis for degradation.

System losses calculation based in monitored data at AJB, Inverter, AWS and

Energy meters.

Pre-Engineering reports for National and International sites

Engineering drawings and site layout preparation based on site topology and

geographical conditions.

Preparation of Yield documents considering tender as well as realistic condition

of site.

White papers on solar technologies for general awareness.

Experience at Solar Energy Centre

Worked in Solar Energy Centre from 19th May, 2008 to 30th May, 2010 as a

Project Fellow.

Designing on SPV Power Plant using Designing Software (PVSYST).

Hand on experience of Installation and commissioning of 20kWp Daily

tracking (Manual) Roof Mounted Solar Photovoltaic Power Plant at

Solar Energy Centre.

Designing of Solar Power Plant Stand alone, Hybrid SPV Power Plant and

Grid Interactive type.

Worked on installation and distribution of Load of 4kwp Solar Power Plant at

Guest House of Solar Energy Centre.

Working on design and development of suitable charge controller for home

lighting and street lighting systems.

Working on long term performance of Mono-crystalline, Multi-crystalline and

Thin Film PV Modules of different manufactures (25Kwp Mono-crystalline

and 21Kwp Thin Film SPV Plants).

Real Time Assessment of lead Acid Batteries of different manufactures

(25Kwp Mono-crystalline and 21Kwp Thin Film SPV Plants).

Load management of Solar Power plants (25Kwp Mono-crystalline and

21Kwp Thin Film SPV Plants).

Transmission & Distribution systems for Solar Power plant.

Long term performance of Street lighting system using LED Lamp and

Lead Acid battery with Mono-crystalline PV module.

Knowledge of Inverters and Charge Controllers used for SPV Power

Plants.

Work experience on 1.2kwp Concentrating Photovoltaic Power Plant.

Designed a Type test setup for testing Batteries at different level of

temperature.

Knowledge of Battery Management.

Experience at ECE Industries Ltd:

Six month working experience as a Testing and Servicing Engineer in ECE

Industries Pvt. Ltd. (Switchgear Division), Sonipat.

I have worked on 11KV and 132KV Vacuum Circuit Breaker, 11KV Oil

Circuit Breaker and manufacturing of Current Transformer for Power

Transformers.

Six weeks Summer training at ECE INDUSTRIES PVT. LTD.(Transformer

Division), DELHI ROAD,SONIPAT During June-July 2005.

Six weeks Summer training at ECE INDUSTRIES PVT. LTD (Switchgear

Division), DELHI ROAD,SONIPAT During June-July 2006.

Any Other Remark:

White paper on “Potential Induced Degradation”.

White paper on “Importance of Bypass and Blocking Diodes in Solar Farms”.

White paper on “Development of Micro-cracks on Crystalline Technology”

White paper on “Hot spot and Degradation in Solar Farms”

Present a paper entitled as “Effect of Temperature variation on Performance of

Lead-Acid Batteries” in ERA-2009 at Chennai.

Attend International Seminar on INDO-JAPAN Photovoltaic technology organized

by NEDO in New Delhi.

Attend National Seminar on Thermal Technology organized by Ministry of New and

Renewable Energy, Government of India, New Delhi.

Education Qualification:

B.E. (Electrical Engineering – 72%) with Honors from Hindu College of Engg.,

Sonipat (Affiliated to Maharishi Dayanand University, Rohtak).

Computer Skill:

Operating System Windows 7/Vista/XP/2000/98

Software’s AutoCAD, PVSYST

Package MS Office

Technical Skill:

Electrical Machines, Electrical Power System(Generation,

Area of Interest

Transmission and Distribution),R&D.

CULTURAL ACTIVITIES:

Participated in many cultural and sports activities in school and college.

Member of discipline committee in ZEPHYR 2004, the college festival.

Second prize in Inter college Football tournament.

Academic Projects:

Title: PWM Based speed control of DC Motor

Nature of Project: Hardware

Tools Used: RELAYS,ICs.

Brief Description: This project is used to the speed of DC motor, by changing input

voltage by PWM. We can control the speed lower than the normal speed.

Interest & Hobbies:

Gymming.

Gardening.

Internet Surfing.

Strength:

Good scientific network

Analytical thinking

Personal Details:

Father’s Name Sh. ASHA RAM

Date of Birth JULY 21, 1985

Language Hindi, English

Marital Status Unmarried

Nationality Indian

References:

Dr. P.C.Pant, Director Mr. Sriparn Sourabh,

Solar Energy Center, MNRE Under Writers Laboratory.

Mobile No. +91-989******* Mobile No. +91-959*******

E-mail- ******@***.** E-mail- ******@*****.***

Declaration:

I hereby declare that the information given above is true to the best of my knowledge.

Date Parveen Kumar