Post Job Free

Resume

Sign in

Electrical Supervisor/Technician

Location:
Surat, GJ, 395023, India
Salary:
N/A
Posted:
April 03, 2012

Contact this candidate

Resume:

RESUME

ANIT D. PATEL

E-mail: -j2s08d@r.postjobfree.com

HP # +65-84549683

India # +91-987*******

Discipline: -

Electrical Supervisor/Technician [Installation/Commissioning/Maintenance & Operation]

Objective: -

Have Self-motivated effective team player with strong inter-personnel skills, qualities & pleasant manners and adaptable to work in a multi ethnic human resources environment. Ability to adapt ideas, methods and environments, also potential to work under pressure. Become a professional throughout in the field of Electrical by dedication & hard-work.

Educational & Technical Qualification: -

SL # Examination Board/University Passed Class

1 S.S.C G.S.E.B October 1997 Second Class

2 I.T.I [Electrical] N.C.V.T July 2000 Distinction

3 I.T.I [(Apprenticeship] N.C.V.T November 2002 Distinction

Summary of Experience: -

Having a certified and qualified in Electrical related with Instrumentation in the field of Oil & Gas, Power Sector & Steel industries with more than 11. years experience. Having knowledge in Trouble shooting, Preventive Maintenance, Corrective Maintenance, Break/Shutdown Maintenance, Installation, Pre-Commissioning / Commissioning - Start-up of Electrical Equipments.

Worked with minimum supervision to minimize down time. Conversant with permit to work system as Cold, Hot, IEA & Confined Space Permit, worked as Competent Electrical Person.

Training Courses Attended: -

• Construction Safety Orientation Course for Workers [CSOCW]

• Oil/Petrochemical Industries Safety Orientation Course for Workers

• Safety Healthy & Environment [SHE]

• Job Safety Analysis [JSA]

• Task Risk Assessment [TRA]

• Job Hazardous Checklist [JHC]

• Safety Induction Course [SIC]

• Electrical Safe Work Practices [LOTO]

• Pre-job Induction Course

• Permit Recipient Course

• Safe Performance Self Assessment [SPSC]

• Basic course of fire fighting, breathing apparatus, Personal protective equipments and Risk assessment awareness.

Total Experience : More than 11 Years

Work Experience: -

1. January 2010 to Till Date

Company : ExxonMobil Asia Pacific Pte.Ltd.

Through [Plant Electrical Instrumentation Pte Ltd]

Project : Singapore Parallel Train [SPT]

Position : Senior Electrical Commissioning Technician

Job Description:

Supervise for Testing & Commissioning of Electrical Power transformers like 132/33KV, 33/6.3KV,33/0.415KV,415/220Volt, ABB & Siemens HT & LV Switchgears and MCC [Like- GIS/SF6/VCB], Motor Control Center [MCC], CT & PT’s, Areva Protection Relays, Motor Protection Relays MM II, 369, & 469, 745 Transformer Management Relay, 750 Feeder Management Relay, MV and LV Motors Solo Run Test, Assisting to the vendor Testing for MM II Relays, Involved in Testing, Commissioning & Functional Checkups of Motors Incomers & Out-going Feeders. Involved in Testing, Commissioning, Pre-Commissioning and Functional Checkups of UPS System, Battery Charging and Dis-Charging, Specific gravity Checking and Voltage Measurements. Carried out Bi-Monthly PM for Substations UPS, Switchgears, Transformers, Annunciatior Panel. PM/Trouble Shooting of LV/MV motors. Involved in Walk down for Substation, plant Lighting-Socket outlet, Transformers, Cathodic Protection Systems and do FCP [Final Clint Punch-list] of Motor and MOV/EBV before Energization.

2. February 2008 to January 2010

Company : Sipchem [Saudi International Petrochemical Company- K.S.A]

Through [Saudi Arabian Kentz company Ltd]

Position : Senior Electrical Technician [Maintenance]

Job Description:

Supervisory experience in Power stations, Installation and Re-installation of all types of electrical equipment in Field Testing, Commissioning and pre-commissioning in Electrical and instruments, power distribution system, HT and LT motors, T-300 medium voltage 4160 volt adjustable speed motor drive [VFD], ACS-800 drives 480 volt [VFD], MVSS [Medium voltage soft starter-controls] and drives, Motor protection relay 469 and 369, 745 Transformer management relay, C 60 breaker management relay, F-35 feeder management relay, Trouble Shooting, preventive maintenance and breakdown repairs on all types of electrical equipment HV & LV Switchgear, MCC [Motor Control Center], MV&LV motors& Transformers. Operation, Maintenance trouble shooting of Control Batteries, UPS, Inverters and its controls, fire alarm and access system, Hydrochloride Package. Carry out Bi-Monthly PM.

3. September 2006 to February 2007

Company : Essar Steel Ltd [India]

Through [ESS Engineering Co. Ltd.,]

Position : Electrical Technician [Maintenance]

Job Description:

Operation, Maintenance & Trouble shooting of AC & DC motor controllers, Electrical Crain, MCC panels & Siemens switchgear. Performs weekly, monthly & Annual Preventive Maintenance of all Electrical Equipments of CRM [Cold Rolling Mill - Department] plant. Maintenance activities of electrical equipments such as medium and low voltage switch gears, Lighting transformers, Distribution transformers of 11/6.6KV, 6.6/3.3KV,6.6/0.480 KV, Power Distribution net work maintenance of HT and LT motors, transformer switch gears, motor starters and MOVs. Maintenance & Trouble shooting of cables with the use of various Instruments, cable laying, Control wiring and MCC wiring.

4. November 2002 to August 2006

Company : Reliance Industries Petrochemical Co. Ltd [India]

Through [Joy Thomas Engineering Co. Ltd.,]

Position : Electrical Technician

Job Description:

Maintenance activities of all electrical equipments such as medium and low voltage switch gears, Lighting transformers & Distribution transformers of 11/6.6KV, 6.6/3.3KV, 6.6/0.480KV, Operation, Maintenance & Troubleshooting of HT and LT motors, Transformers Switchgears, Motor Starters and MOVs. Cable laying, glanding and termination of Cables.

5. January 2001 to October 2002

Company : Himson Engineering Ltd.,

Position : Electrician

Job Description:

During One year Apprenticeship training and Duties involved in Assembling, Installation, Testing and Commissioning of three phase and single phase panels. Modification of the panel internal wiring connections as per site requirements. Maintenance and trouble shooting of electrical connections, accessories and installations/equipments.

Area Of Responsibilities Involved: -

Supervisory for all kinds of Electrical system test from field to Console & coordinate with the client to witness and approve the tests that have been carried out at site.

Fully involved in preliminary testing & installing of protective relays, Breakers, CT & PT, Power Transformers, MCC, AC Drives, Motor, NGR, PMS Panel, UPS Batteries.

Provide support to the vendor/service engineer during trouble shooting, inspection/repair, design changes and modifications to the control systems.

Respond to emergency call outs, troubleshoot the problems and take action to ensure the correct operation of the Electrical equipment.

Responsible to during plant Shutdowns perform the preventive maintenance of entire protective relays, Switchgears and MCC.

Comply with all company Health, Safety and Environment as well as Work Permit, policies and procedures.

Monitor the start up, testing, commissioning of the work.

Performs individual shift duties and other tasks as assigned.

Attend any emergency work and solve Critical Problems in reasonable time.

Having good leadership, communication, presentation, interpersonal relation and motivational skills.

Personal Details: -

Name : Patel Anitkumar Dahyabhai

Permanent Address : 59, Ratannagar Society, Bhestan, Surat,

Gujarat - 395023 India.

Date of Birth : 04th June 1982

Nationality : Indian

Religion : Hindu

Marital Status : Single

Strengths : Friendly, Adjusting, Team Player Hobby Reading, Listening to music & make friends

Languages : English, Hindi & Gujarati

Computer Skills : MS word, Excel SAP & Internet Explorer

Passport Details: -

Passport # : E 9001631

Date of Issue : 19-05-2004

Date of Expiry : 18-05-2014

Place of Issue : Surat [Gujarat]

Declaration: -

Here with I declare that all the above information and data’s are true to the best of my knowledge and assuring that all the maximum possible efforts will be delivered by me to improve the Business.

Date: -

Anit D Patel



Contact this candidate