Post Job Free

Resume

Sign in

API 510/570 NDE LII 19

Location:
Casper, WY
Salary:
$50.00@hr
Posted:
August 14, 2020

Contact this candidate

Resume:

Jason B. Ramirez

Casper, WY ***** 307-***-**** adfb2q@r.postjobfree.com

API -570, API-510, with 19 years NDE LII Trainer experience in the oil and gas industry. Able to operate in any condition keeping production at its peak while maintaining the highest safety and quality standards. Experienced in oversight of NDE, performing quality and safety audits in addition to providing insight on most efficient and cost-effective manner to go about obtaining requested data. Capable of simultaneously coordinating multiple crews while also performing API internal and external inspections and generating detailed reports. Strive to project a safe, professional, and profitable company image to optimize all opportunities to maintain and/or create positive client relations.

SKILLS AND PERSONAL STRENGTHS

Exceptional customer service skills.

Successfully interact with clients and crew members to create a positive working environment.

Possess excellent organizational and time management skills to meet company standards, goals and deadlines.

Conscientious, hardworking and drive to succeed.

Trustworthy and reliable.

Proven ability to adapt and learn new skills quickly and efficiently.

Ability to coordinate multiple inspection crews in field on multiple tasks.

RELEVANT EXPERIENCE

Review job scope and data provided by company.

Coordinate inspection activities.

Track job progress in Smart Sheet, give weekly reports to Owner Representative, report any issues that needed immediate attention.

Utilize handheld tablet in field.

Conduct API- 570, API-510 internal and external inspections, report findings and make recommendations as per client specifications, applicable code standards and recommended practices.

Perform CR, RT, MT, PT, UTT, VT, Hardness examinations on piping and vessels at fab shops and field locations including pipelines, chemical plants, refineries and well pads.

Experience with interpreting P&IDs and isometric drawings.

Experience with updating isometric drawings to current as inspected equipment and piping configurations.

Experience with assigning CML’s as per CMD’s to specifically target known damage mechanisms to maximize inspection data by utilizing most effective NDE method.

Verify Dimensional Specifications and Collect FFS/SFS Data.

NDE of tanks, castings, and special parts for clients on field location or customer shop.

Train NDE personnel to perform CR, RT, MT, PT, UTT, VT and Hardness.

Evaluate new candidates applying for Technician positions.

EMPLOYMENT HISTORY

11/2019 - 02/2020

Element Integrity Group @ Energy Transfer Facilities in Oklahoma and Texas

Project Lead - API-570/510 Inspector

Review Scope and data provided by company, build inspection activities packages in a manner that would allow examiners and inspectors to work simultaneously in the same area provided all safety concerns have been mitigated. Set up delivery and pick up of rental equipment needed to perform elevated inspection activities. Review JHAs and rental equipment daily inspections. Report any mechanical integrity or safety issues to client representative that needed immediate attention as specified in either client specifications or company procedures. Attended Kickoff and closeout meetings.

06/2019 – 10/2019

IRISNDT @ Marathon Mandan ND Refinery

Night Supervisor API-570, API-510 NDE LII RT, MT, PT, UTT

Coordination with Project manager of Low RE project in the HF Alky Unit, oversite of 2 Profile RT crews, perform walk downs of acid containing circuits, identifying weld locations and submitting modified isometric drawings with weld locations and as observed asset configuration in blue beam format. Also provided experienced based advice to NDE crews and planner as to most efficient and cost-effective manner to obtain data. Review and verify profile RTs meet procedure specification. Recommended additional locations or rework of nonconforming PRT images based on data provided and predetermined job scope. Perform API visual inspections upon request from operations when issues presented themselves and made recommendations for NDE to provide data for review by Marathon Inspections Department first thing in the morning. When lighting permitted also perform visual external API 510/570 inspections to help Operate and Maintain project stay up to date on upcoming inspections.

05/201*-**-****

Sentinel Integrity Solutions @ ETC JAL, NM #3 Facility

API-570, API-510 Inspector

Performed CUI focused Visual External API-510,570 in-service inspections. Identify suspect locations utilizing customer specifications. Verify moisture content of insulation by utilizing FLIR moisture probe after performing Thermography on suspect locations that could not be accessed due to insulation jacketing, in an effort to provide ETC with data to make a determination to the extent of initial follow-up inspection needed to further asses the condition of asset surfaces in relation to corrosion under insulation.

02/17-04/2019

Braun Intertec @ Sinclair Casper, WY Refinery

Site Lead / API-510, API-570 NDE II CR, RT, MT, PT, UTT, VT

Perform profile RT of assets according to client requests and report any anomalies to

unit inspector for disposition. Provide NDE support on various maintenance projects and

new construction projects as needed.

Also maintained outside refinery project relationships with construction contractors to

support projects in the Casper Wyoming Area.

08/16-11/16

Advanced Corrosion Testing @ Conoco Lost Cabin Facility

LII Trainer CR, RT, MT, PT, UTT

Performing Profile and Weld Quality NDE inspections on Level Bridle project.

In addition to NDE support of new construction pipeline projects associated with Gas

Plant operations, and maintenance projects within facility

•02/16-4/16 - NIS Inspection Houston, TX - LII RT, MT, PT, UTT, VT, Trainer

•11/15-01/16 - Edge Inspection Benicia, CA - LII RT, PT, MT Trainer

•4/15-6/15 - Mott Tank Inspection LA Port, TX - UTT LII and assisted with API 570 and 653 inspections.

•11/14-3/15 - Metco/Mistras Houston, TX - LII RT, MT, PT

•07/13-10/14 - Diamond G Inspection Houston, TX – LII RT, MT, PT, UTT, VT Trainer

•11/12-06/13 - Savoy Technical Services Houston, TX- LII RT, MT, PT, UTT

•05/12-09/12 - High Mountain Inspection Greely, CO- LII RT, MT, PT, UTT

•04/12-05/12 - On Demand Inspection Riverton, WY - Self Contracted to Devon Energy Beaver Creek Gas Plant to compile UTT Baseline. Data consisted of Thickness readings, assignment of CML’s, photographs and drawings. API 570 work.

EMPLOYMENT HISTORY (CONT’D)

•01/12-03/12 - ITI Inc.- Onsite LII at Western Refining

•10/11- 01/12 - Enerflex - Skid and Vessel QC Dept. LII RT, MT, PT, UTT, VT

•08/11-10/11 - DBI NDT- Lead Field Tech RT, MT, PT, UTT

•06/11-07/11 - Turner Specialty Serv. – LII RT, MT, PT, UTT

•02/10-04/10 - TechCorr USA - LII RT, MT, PT, UTT

EDUCATION AND TRAINING

Mark Smith API 570, API 510 training – 120 HRS.

The Ocean Corp – 8/2003, Houston, TX - Classroom hours RT, MT, PT, UT, VT, ECT as per SNT-TC-1A, 40 Hr. Radiation Safety.

Current Aerial lift training.

OSHA 10.

Current ND safety council card.



Contact this candidate