Pritpal Singh
Mississauga Ontario L4T 1W7
acvi9a@r.postjobfree.com
Objective:
An experienced professional seeking position of Maintenance Supervisor.
Summary of Qualifications:
Result-oriented professional with more than 12 years of valuable experience in:
Preventive maintenance
Predictive maintenance
HACCP
GMP
Boiler
Air Compressor
Cooling Towers
HVAC
DCS/PLC/SCADA
OHSAS-18001:2007
Troubleshooting
Calibration
Sensors and Encoders
Vendor/Contractor Management
Automation
Instrument Installation
Commissioning & Loop Testing
HAZOP
ISO-14001:2004
BSC (British Safety Council)
Lean manufacturing
Process flow
Budgeting
Procurement
Inventory Management
Root Cause Analysis
FAT/SAT
MS Office (basic)
TPM
ISO-9001:2008
Highlights:
Direct and lead the team in preventive and preventive maintenance activities for safe and efficient operation of all plant production equipments like processing and packaging machinery and office equipments and utilities like Steam Boilers, cooling tower, air compressors and HVAC etc.
More than 8 years at supervisory position in plant maintenance department leading the team of engineers and technicians performing work planning, scheduling and motivating the team
Coordinated with other departments like production, materials, administration and developed a co-operative team approach
Coordinated with all outside contractors and ensure that work is completed in a safe manner that complies with all necessary manufacturing codes, regulations and standards like H&SE, GMPs and HACCP etc.
Hunted for opportunities to continuously improve on maintenance operations and efficiencies
Assisted senior management in establishing and implementing operating and capital Budgeting and put controls to avoid overruns.
Work Experience:
2012-2016 Manager Plant Engineering, Asian Paints Ltd. India
Maintained and up-kept plant processing and packing machinery, ASRS, control systems and utilities like steam boilers, chillers, air compressor, Diesel generator for a paint producing plant with capacity of 0.25 Million KL of paint per year.
Analyzed the breakdowns, performed Root cause analysis, recommended and implemented corrective actions (CAPA) for all major breakdowns
Established an Preventive maintenance system, predictive maintenance system and Instrumentation calibration system in order to keep all equipments in service and all measurements are accurate to the desired level
Identified potential areas of improvements (e.g. bottlenecks), recommended changes and ensured the implementation of recommendations
Deployed measured to achieve the target of 80% Preventive/predictive maintenance and 20% or lower breakdown maintenance
Prepared and reported on monthly performance of the department to the management
2007-2012 Section Head Instrumentation, Pidilite Industries Ltd. India.
Performed Preventive and breakdown maintenance of automatic process controls and other fully automatic pouch filling machines, Jar Filling Conveyors, inkjet coders, label printers and load cell based weighing systems
Performed changes in hardware, software, control system design, Graphic design, configuration, and testing as per process requirements for safe working and to save manpower and energy on DCS system for Manufacturing Process
Maintained minimum critical spare part inventory and prepared yearly instrumentation department budget
Worked on OHSAS 18001:2007 and TPM
Provided discipline input during HAZOP & design reviews, both internally and with the client
2006-2007 Assistant Executive Electronics, Vardhaman Yarns and Threads Ltd. India.
Established and implemented preventive maintenance scheme to upkeep all utilities (DM water, Steam, Electricity, AHU) and winding and dying machines
Deployed measures for cost saving and energy saving
Lead and managed the team of Shift Engineers, electricians, fitters, operators and technicians
2003-2006 Instrumentation Engineer, Jagatjit Industries Industries Ltd. India.
Performed Preventive and corrective maintenance of DCS PLC and SCADA systems
Worked as per GMPs and HACCP standards
Maintained control valves with pneumatic actuators & done relay logic troubleshooting
Proficient in working on Limit switches for flow, level, pressure, temperature, proximity switches, photo switches and solenoid valves
Programmed configured and troubleshoot AC Variable Frequency Drives
Tuned PID setting for Single loop and multi-loop Controllers with single set point and multi set point controlling
Calibrated smart and non smart Transmitters for Flow (mass flow, magnetic flow, and vortex and DP type), pressure, level and temperature and pH meter etc with conventional methods and with simulators and HART communicator
Education:
1999-2002 Instrumentation Engineering, Bachelor of Engineering
Punjab Technical University, India.
1997-1999 Instrumentation and Process Control, Diploma
Sant Longowal Institute of Engineering & Technology India.
1995-1997 Electrician, Certificate Course
Sant Longowal Institute of Engineering & Technology India.
REFERENCES AVAILABLE UPON REQUEST