NARENTHIRAKUMAR J

** /*, *************** *****

West saidapet

Chennai – 15

Tamil Nadu

acthkz@r.postjobfree.com Mobile: +91-887*******

OBJECTIVE

To actively contribute to the development and growth of the organization where my management, analytical, technical skills and Practical experience could be utilized to the fullest extent and in the process, gaining more knowledge and experience to achieve my career objective in a responsible position.

SYNOPSIS

Having around 17+ year's Professional experience in the field of HVAC (Heating Ventilation & Air-conditioning System), such as Heat Load calculation, Ventilation system, Selection of equipment, Ducting, Piping and Plant room layout for different types of Buildings.

Also involved in Drafting & Preparing of Ducting, Piping and Plant room layout and MEP Co-ordination drawing for IT parks, Hotels, Hospitals, Malls and Residences of Buildings.

CODES, STANDARDS & SOFTWARES

Standards : ISHRAE, ASHRAE, SMACNA, DW-144.

Softwares: Auto CAD, Micro station & PDS, PEHVAC, PDMS, NavisWorks, Jet stream, HAP 4.50

EXPERIENCE

Working as Senior Design Engineer (HVAC) for Dakshin Plant Engineering Consultants Private Limited, Chennai - March 2013 to till date.

Projects involved:

Deputed on TECHNIP INDIA LTD. CHENNAI.

YAMAL LNG PROJECT – Drain Mercury Removal Unit 1 & 2.

Deputed on SAIPEM INDIA PROJECTS LTD. CHENNAI.

EPC- Booster Station 171 (BS 171 for KOC)

WORK EXPOSURE:

Heat load calculation, Selection of HVAC equipment

Pump head calculation

Pressure drop calculation for AHU Fans and Ventilation Fans

Using HVAC layouts for 3D Modeling in PDS, PDMS

Guidance to CAD team to prepare 2D Section and Drawing preparation

Co-ordinate with other MEP services (co-ordination for location of HVAC outlets with other discipline like electrical, firefighting and instrumentation)

Inter Discipline Co-ordination (Provide HVAC electrical load to electrical department, to obtain equipment heat dissipation from electrical and instrumentation department)

Man hours estimation

Worked as Design Engineer (HVAC) for ETA M&E Dubai - Since Feb 2011 to Feb 2013.

Project Involved: Cleveland Clinic (CCAD) - Abudhabi, UAE.

WORK EXPOSURE:

Checking the HVAC layouts, Calculations and giving instructions to site HVAC engineers and team for the installation of HVAC systems, which includes Chillers, Air handling units, Air cooled condensing units, Fan coil units, Ducting, piping, Ventilation systems, etc…

Co-ordination with other services & Resolve the MEP clashes on site

Making FRFI & RFI as per site condition and get approval

Checking MEP coordinated Drawing, Checking of the Utility flow diagram.

General arrangement drawings as per client's specifications & standards.

Preparing and maintaining the quality drawing for Audit purpose.

Worked as Principal Designer (HVAC) for Petrofac Engineering Services, Chennai - Since May 2008 to Feb 2011.

Projects Involved:

Karachaganak 4th Stabilization and Sweetening Train Project

EL-MERK

Jihar Stage-3

Brass LNG

Lukoil

Wara Pressure Maintenance Project

KNPC North LPG Tank Farm

WORK EXPOSURE:

Heat load calculation, Selection of HVAC equipments, Duct design,

Piping Design, Preparing the Data sheet for the HVAC equipments

Preparing the Bill of materials for HVAC system.

Inter discipline inputs giving to Civil, Electrical, Process & Piping.

Preparation of Utility flow diagram, General arrangement drawings etc…

Co-ordination with other MEP services.

Plant Room layout Preparation.

Pressure Drop Calculation for AHU Fans and Ventilation fans.

Pump Head calculation.

Equipment Schedule Preparation.

Using HVAC layouts for 3D Modeling in PDS, PDMS.

Worked as Senior Designer (HVAC) for Mott MacDonald, Engineering Services Chennai - Since Aug 2005 - May 2008.

Projects Involved:

Bahrain City Center, Bahrain.

Deira City Center, Dubai.

Kestral Power Station.

Dubai Investment Park, Dubai.

Iraq Army 3rd Battalion and Rcc Camp, Iraq.

DBE Police Services, Iraq.

Ashfield School

WORK EXPOSURE:

Designing and drafting for ducting in centralized cooling systems for Hotels, Malls, Office & school.

Preparation of Ducting layout for Kitchen Air-conditioning and Ventilation systems.

Chilled Water, Hot Water Schematic layout Preparation.

Pressure Drop Calculation for AHU fans and Ventilation fans.

Pump Head calculation.

Equipment Schedule Preparation.

Plant Room layout, 2D-Section and Detail Drawing Preparation.

Co-ordination with other MEP services.

Preparing and maintaining the quality drawing for Audit purpose.

Worked as CAD ENGINEER for VASU SYSTEMS & SOLUTIONS, Chennai, India - Since Apr 1997 - Jul 2005.

Projects Involved:

Chennai Deluxe Hotel, Chennai.

Ophthalmology Hospital for Kerala Health care Ltd,

Dental College for Sri Ramachandra Medical Trust.

Accenture IT Park Phase I, II. Chennai.

Reliance Info com for Reliance Industries Ltd.

Gokulam Hospital and Medical College for Gokulam Trust.

WORK EXPOSURE:

Preparation of HVAC drawing like plant room, ducting, Preparation of shop drawings.

Preparation of Bill of Quantity (BOQ), piping and chilled water schematic.

2D-Section and Detail Drawing Preparation.

Preparation of co-ordination drawing with other services like fire fighting, electrical and public health.

ACADEMIA

B.E. Industrial Engineering (Part time) from Anna University.

Diploma in Mechanical Engineering, T.R.N. Polytechnic, Dharapuram, Erode DT.

PERSONAL DETAILS

Date of Birth : 09-06-1974

Nationality : Indian

Marital Status : Married

Language known : English, Tamil & Hindi

Passport Number : J 1943923

Expiry Date : 24.06.2020

Issued Date : 25.06.2010

Declaration:

I am confident of my ability to work in a team; I hereby declare that the information furnished above is true to the best of my knowledge.

Place:

Date:

(NARENTHIRAKUMAR J)