Resume:

MUHAMMAD NADEEM

Electrical system erection & commissioning,

operation and maintenance supervisor/technician.

PLEASE REPLY TO CHAK # 105/15-L,

VANJARI TEHSIL MIANCHANNU

DISTRICT KHANEWAL PAKISTAN.

Contact #: +923*********, 009***********

E-mail: actfkg@r.postjobfree.com .actfkg@r.postjobfree.com

OBJECTIVES

Looking for an opportunity to work with a progressive organization where I can refine my present skills, prove my work and get a chance to handle challenging assignments.

Exam.

Institution

Board

Year

Matric (Sc)

Govt.H. S. School Vanjari

Multan

1997 1st

DAE Elect.

GCT Sahiwal

PBTE Lahore

2000 1st

M.S Office

National Computer College Multan

Multan

2002 1st

B-Tech (Pass)

Preston University Kohat

Kohat

2010 1st

ACADEMIC QUALIFICATIONS

WORKING EXPERIECE 14years

POSITION

COMPANY

FROM

TO

ELECTRICAL TECHNICIAN

OMV EXPLORATION AND MAURICE ENERGY LTD PAKISTAN

05/04/2013

CONTINUE

SR ELECTRICAL TECHNICIAN

PAK ARAB FERTILIZER MULTAN PAKISTAN

04/10/2006

04/04/2013

ELECTRICAL TECHNICIAN

FAUJI FERTILIZER COMPANY SADAKABAD PAKISTAN

05/12/2005

03/10/2006

APPRENTICES ELECTRICAL TECHNICIAN

FAUJI FERTILIZER COMPANY SADAKABAD PAKISTAN

29/10/2003

28/10/2005

ELECTRICAL TECHNICIAN

SUI NORTHERN GAS PIPE LINE COMPANY PAKISTAN

08/09/2000

25/10/2003

MY RESPONSIBILITIES

Ensure facility system and safety critical equipment’s are maintain in a safe and efficient manner and provided supervisory support for reliability and integrity management

Supervise and perform scheduled maintenance activities (corrective and preventive) on variety of electrical equipment’s (generators, motors, transformers, VFD, soft starter, UPS etc.)

Supervise to subordinate and contractor jobs and ensure compliance with safety requirements, timely manner and as per standards procedures.

Prepare to electrical maintenance procedures and required task risk assessment for critical activities, and then ensure that job is carried out strictly in accordance with TRA.

Coordinate with operations and other disciplines to plan the safe and successful maintenance of equipment and Facilities

Participate in carrying out the annual turnaround(ATA) or major equipment turnarounds in the Plant

Supervising and coordinating the evaluation of machinery operation and condition through maintenance, inspection and testing as well as critical device function test (CDFT).

Perform inspection, repair, adjustment, testing and calibration of electrical and instrument Equipment and systems in accordance with technical manuals, drawings Manufacturer’s specifications and standards.

Ensure accurate documentation of completed work is captured on work orders

Raise material services requisition (PR) of necessary spares, tools and materials in CMMS (SAP) and on its arrival at the site identifying any divergence of the same from the original documents. Ensure that adequate levels of spares are maintained and spare parts consumption by revising E&I Maintenance procedures to reduced plant down time

Adhere to maintenance planning and schedules. Ensure compliance with safety requirements and Standards procedures.

Prepared scope of work for plan maintenance. Provides technical support during implementation of electrical projects work.

Investigated and analysis the equipments failures and prepare report to remove root cause

Troubleshoot identify actual and potential problems areas and implement solutions to ensure Maximum effectiveness, best practices application.

Communicates effectively with others, both verbally and in writing.

Attended important in house meeting and trainings and implementing their importance

Carry out roles and responsibilities of superior during his absence

Implement of organization's safety policies at site

Practical Knowledge & Experience And key Skills

TRANSFORMERS (ABB, Siemens, Brush, PEL)

LV & MV transformers rated 100 kva to 5 MVA

Preventive and Corrective Maintenance, Field Servicing, Oil Testing and Replacement of oil. Inspection of Both LV/HV Side Bushing, Insulation testing, testing of Transformer Safety. Devices Relay Testing, Tap Changers, Insulation Test and etc.

GENERATORS (General Electric, BBC, Cater Piller, MTU, Waukesha)

Perform Inspection,maintenance,replacement, trouble shouting,testing of Gas turbine, Steam turbine, diesel engine and gas engine generators( 400V to11KV,18.5Mw,and their protection system .

Commissioning of Generators and prime mover securities', AVR and electronic governor, interconnection wiring, replacement and maintenance of spark plug ignition system.

General troubleshooting/ maintenance of exciter, generator and engine.

Diesel Engine Driven Generators Overhauling, Maintenance, troubleshooting, of Governors, AVRs, exciter, Rotating Rectifiers.

TRANSMISSION LINES

400V,11KV to 132KV

Preventive and Corrective Maintenance, Field Servicing, and testing of its protection system

Medium and Low Voltage Motors (ABB, Siemens, Inslado, Loher, Bauer euro motri )

LV & MV motors & MOVs (Limitor Biffi) rated up to 0.75kw to 4000kw respectively, Perform Preventive and Corrective Maintenance. Overhauling, new installation, insulation testing, troubleshooting,,connection, disconnection,overhauling and bearing replacement and over all Inspection of LV and HV Motors.

Medium and Low Voltage Switchgears (ABB Sace, AEG, Nova Magrini Galilo Itly, Siemens, Terasaki, GEC UK schenider electric )

Perform preventive, corrective maintenance, replacement trouble shouting, repairing work on following types of MV breakers SF6, VCB, Vacuum Contactor, OCB, ACB, Air Magnetic CB rated up to 3200amp.

Magnetic contactors up 3200 A 11KV on MV/LV

Testing and commissioning of all above breakers and contactors,and its protective relay system.

I have very good trouble shouting techniques of control and power system of all above breakers on all types of circuits

VARIABLESPEED DRIVE&SOFT STARTER UP TO 4 MW:

Perform preventive maintenance of VFDs and soft starters also Checking of power FET, s and SCRs. Setting and testing of over load and short circuit protections, VFDs and soft starters of ABB up to 200 kW.

PROTECTIVE RELAYS (CEG France, Fir Italy, Siemens, ABB,GE)

Electro-magnetic, Electro-static/Microprocessor based /Numerical protective relays

Familiar with operation and testing of Micro Processor Based Generator, Transformer Protection Relays, Electronic and Microprocessor type. like Earth fault, over current, Differential, under/over voltage, Under/Over frequency, Loss of excitation, over fluxing, Under Impedance, Negative phase sequence and thermal image and etc

UPS (Sice, Alamo 8,.Borri)

Perform preventive .corrective maintenance, replacement of parts and trouble shouting work on Online UPS rated up to 2x80 KVA

BATTERIES (Saft france, Varta Alcad)

Perform maintenance, replacement and testing according to its maintenance and new installation of Lead Acid and Nickel Cadmium batteries for UPS, DCP, and other dc sources.

MV and LV CABLES JOINTS & TERMINATION (Oconite, Kerpenwerk, Pakistan, Newage. oman cables )

Perform cable Laying, lugs connecting, Jointing, Gland installation and terminations .insulation testing of LV and HV cables up to 600mm2 .XLP, PVC .EXLP.also oil filled paper insulated cables.

CATHODIC PROTECTION

Preventive Maintenance of Cathodic protection system (Impressed current), its

Transformer testing of auxiliaries related control and power circuits and current

regulation circuit.

OVER HEAD CRANES AND ELEVATORS

Maintenance Trouble shooting the interlocking of overhead cranes and vertical lifts.

MISCELLANEOUS

PA System, Rotary & Static Frequency Converters, Mercury, Sodium & Incandescent lights,, Lathe Machines, Power Grinders, Industrial & Domestic Electrical Wiring Thermocouples and R.T.D (Resistance Temperature Detector), Control Valves Actuator, Damper and Positional, Electro-Pneumatic Converters, Load Cells, Transducers and Sensors (DP, Magnetic, Ultrasonic, Proximity, Optical, Floating and Radio Active type), Manifolds, Pressure Safety Relief Valves, Solenoid, Motorized Operated Valves,etc

FAMILIAR WITH USE OF

Battery/hand operated Megger, Analog/Digital Multimeter, Analog/Digital Ampere meter, RTD Decade Box, Lux Meter, TTR Tester, Temperature Detector, Milliohm Meter, ELCB Tester, Clamp-on Grounding Resistance Meter, Explosively Tester, Oil Treatment Machine, Cable Fault Locator, Current Injection &relay testers set etc.

OFFICIAL TRAINING

Training on Electrical Relays testing and calibration conducted by FFC

Training on storage batteries conducted by FFC

Training on Hazardous Areas Classification and Hazardous Material Response conducted by FFC/OMV

Training on Work Permit Procedure (conduct by FFC / Pakarab Fertilizers /OMV)

Training on Fire Fighting(conduct by FFC / Pakarab Fertilizers/OMV Hasin Habib civil aviation)

Training on Confined Space and Rescue conducted by FFC/OMV

Member on Fire Fighting Emergency Response team at FFC/OMV

Electrical Safety & General Safety, Safety Equipment and First Aid Training conducted by FFC/ OMV

Training on first AID

SPECIAL TRAININGS

Safe Operating Procedures (SOP)

Work Permit Procedures

PSRM( PROCESS SAFTY AND RISK Management System (IMS)

Fire Fighting and use of protective equipments

Computer Literacy

Material management system .SAP

SAFETY CONSCIOUS

Fully aware of industrial safety & its compliance Health, Safety and Environment (HSE) and permit-to-work (PTW) system against personal safety as well as plant safety or emergency handling.

Follow the SAFETY procedure standards like Housekeeping, Work Permits; Fire fighting, Noise pollution, Confined spaces, Excavations work, First Aid and uses of PPE (Personal protective Equipment), Incident/Accident investigation.

Member of safety committee to discuss the issues about safety health and environment and to aware peoples about risk and personal safety through tool box talk and safety meetings and take actions to prevent unsafe acts and working inside the plant area.

ERECTION AND COMMESIONING

I HAVE ERECTION AND COMMECTION EXEPERENCE AT OMV MEHER FIELD OF MOTORS, GENERATORS, SWITCH GEAR, UPS, CP SYSTEM DIESEL ENGINES

PERSONAL BIO-DATA

Father’s Name : Muhammad Ashraf

Date of Birth : 09-02-1980

N. I. C. No. : 36104-0432034-9

PASPORT NO : BG9450342

Driving licence : 26777

Marital Status : Married



Contact this candidate