Zameer Hussain
CELL NO : +923*********, 345-***-****
SKYPE ID : zameerrai
EMAIL ID : acte68@r.postjobfree.com
SEEKING ASSIGNMENT AS AN INSTRUMENT TECHNICIAN
PERSONAL STATEMENT:
As growing professional in the field of instrumentation, I would like demonstrate my skills and abilities in a target oriented and progressive milieu with a vision to further develop and utilize my professional expertise and inter-personal skills towards effective growth of the organization.
QUALIFICATION:
3 Years Diploma from Govt. Collage of Technology, Sahiwal Pakistan.
Matriculation Govt. High school Sadar Gogera Okara Pakistan
PROFESSIONAL EXPERIENCE:
IPP 26 MW Thermal Power Plant, OMS Co (Operation & Maintenance Services Co) Pakistan.
Position: Instrument Technician
Date: Jan 2014 to till date.
Engro Eximp Agri Product:
Position: Instrument Technician
Date: April, 2012 to Jan, 2014
Engro Crop:
Position: Instrument Technician
Date: Sep, 2008 to Jan, 2012
TECHNICAL SKILLS:
Excellent understanding P&ID, WIRING diagram.
Installation, calibration and maintenance of various types of control valves and motor operated valve (MOV).
Responsibility to carry out the routine predictive and preventive maintenance of different types process control instruments.
Involved commissioning, fault findings, interlocks, wiring junction panels and field loop checking.
Maintenance, repairing, calibration, and troubleshooting of different type of process instrument like flow, level, temperature, pressure transmitters, thermocouples, RTD, flame scanners, igniters, sensors, pressure switches, level switches, posittioners, solenoid valves, temperature and pressure gauges Etc.
SHUTDOWN ACTIVTIES:
During the plant shutdowns and turnaround performed the following activities:
Calibration of pressure and temperature instruments Gauges, switches and Transmitters.
Calibration of Level instruments like displacer type and DP type transmitters.
Maintenance and Calibration of control valves Mov,s
CALIBRATION & TROUBLESHOOTING OF DIFFERENT INSTRUMENTS:
I performed my duties independently and worked on different types of conventional and foundation field bus instruments maintenance, calibration and troubleshooting.
Flow Transmitters.
DP type, Magnetic, Turbine, Ultrasonic, flow transmitters of different companies Yokogawa, Yamatake,
ABB Smart Type Honeywell and Fuji. Foxboro, Rosemount.
Level Transmitters.
DP type, Capacitance type, Magnetic, Ultrasonic, Radioactive, and
Radar type, transmitters of different companies Yokogawa, Yamatake, and ABB Smart
Type, Rosemount, and Honeywell etc.
Pressure Transmitters.
Diaphragm type, Pressure transmitters of different companies Rosemount,
Yokogawa, Yamatake, ABB Smart Type, Honeywell and Foxboro.
Temperature Transmitters.
Worked on different types of temperature elements RTD’s, Thermocouples,
Temp Gauges and transmitters of different companies, Rosemount
Yokogawa, Yamatake, ABB Smart Type, Honeywell and Foxboro.
Analyzers.
PH and CONDUCTIVITY analyzers of ABB, YOKOGAWA, Rosemount, HANA and Polytron,
H2S combustible gas detectors of General monitors
Posittioners.
Fisher, Goldey, Arca, Siemens, Honeywell, Masoneilan, ABB.
Control Valves & Shutoff Valves.
Fisher, Goldey, Arca, Siemens, Honeywell, Masoneilan, Xomox, Flow serve, ZV
KV Mestonel and NXV Maxseal, XV (Topworx, Betties). (Leden, Biffi)
Motorized Valve (MOV)
Biffi, Rotork, air power, auma
VIBRATION MONITORING SYSTEM:
Worked on Vibration monitoring system of Bentley Nevada 3500 and performed the Following activities.
Worked on different types of vibration probes (Radial, Axial, and Seismic).
Check and verify the machinery protection system DCS configuration.
For applicable loop, adjust the gap voltages.
Used the modulator (TK-3e) for the simulation of Vibration loops.
STANDARD EQUIPMENTS FOR CALIBRATION:
Hand Held Communicators such as SMART (Honeywell, Yamatake) & HART Rosemount 375 and 475.
Yokogawa BT 100, BT200, FF (Foundation Field bus 375,475 Communicators).
Electronic Calibrator (CA - 100 by Yokogawa).
Volt /MA Calibrator (Model JOHN FLUKE 715).
Digital Pressure Calibrators (Druck model DPI 603, DPI 610, DPI6101S, DPI615).
Temp. Calibrators Jofra calibrator (A meter Model 650 SE).
Dead Weight Tester (Procurements Limited Model M 2200/3), Ruska
Decade Resistance Box (Model CROTECH DRB-11).
Pneumatic Calibrator (Eurotron Model Micro Cal).
Process Calibrator, Simul/Meas, RTD, TC, HZ, mA, mV.
SYSTEM EXPERIENCE
DCS by Yokogawa centum CS 3000 and centum VP
PLC by Siemens Semitic S7-300/400
PLC by Triconex for ESD System.
PLC by Allen BradleyControl Logix 1756-L63 (5563),
VMS (Vibration Monitoring System) Bentley Nevada 3500.
BMS (Burner Management System) PLC by Triconex.
Reliant compressor Control Corporation & FS Elliot USA.
HSSD (High Sensitivity Smoke Detector) Siemens
HSE INDUCTION:
Familiar with all safety aspects related to oil refineries. Excellent understanding of HSE standard like color coding, Electrical safety, Hearing protection, Heat stress, gas leakage prevention and evacuation, Tool safety, Radiation safety, accident reporting, TRA, PPE, Confined space entry, occupational health and Hazardous waste management system, and routine, safety, talks. I participated joint HSE campaign.
PERSONAL DETAIL:
Father’s Name : Talib Hussain
Date of Birth : 20-June-1987
Nationality : Pakistani
Religion : Islam
Marital Status : Single
Passport No : YH6899111
CNIC No: 35302-4783911-5
I am submitting my resume for your kind perusal. I hope my qualification and experience mentioned in the CV will meet your requirements. I would be glad to be called for an interview. Zameer Hussain