Post Job Free

Resume

Sign in

Manager Engineer

Location:
Jalalpur, GJ, 364740, India
Posted:
December 29, 2015

Contact this candidate

Resume:

Bharat B. Shukla

Contact: +91-987*******/Email: acsx2j@r.postjobfree.com, acsx2j@r.postjobfree.com

SUMMARY

Profile: Male, Age

Nationality: Indian

Current Location: Gujarat, India

Driving Licences: 005733/00GJ05 valid from 5 Jan’00 to 4 Jan’20 Passport Details: J5645786 valid from 06/05/2011 to 05/05/2021

No. of Dependents: 3

Current Position: Senior Manager

Current Organization: Essar Steel India ltd

Preferred Location: Anywhere in the Gulf and India

Salary Expectations: Negotiable

CAREER OBJECTIVE

A qualified electrical engineer with 19+ rich years of hands-on experience in handling and maintenance of substations. With Energy Manager Certification under his belt, has the potential to take on leadership roles. Is well versed with the latest technology and believes in upgrading self and team with constant training and coaching sessions. His teams’ looks up to him for well researched solutions during troubleshooting. Has the ability to take calculated risks and initiative to improve processes. Great interpersonal skills lead to the capability of dealing with people from all walks of life and develop win-win solutions.

WORK EXPERIENCE

Jun’09-Till Date Essar Steel India Ltd, Surat

Senior Manager

Accomplishments

QC Project on Synchronized islanded 220 kV bus with grid and

QC Project on tripping of 220 KV Bus coupler during bus transfer

Worked on capacity enhancement of power transformer as green belt project.

Conduct training for new diploma, graduate training, juniors and associates different topics.

Responsible for reduction of breakdown through the different condition monitoring technique like thermographs, gantry insulator testing, cable testing,

Ultrasonic survey on different electrical equipment

Identified and resolved the DGA test gas problem in transformer selector switch

Maintain Auxiliary systems of substation like HVAC, Ventilation system, DC/AC distribution, battery bank, battery charger, SVC cooling system among others.

Promoted often for exemplary work ethics and initiatives taken.

Recipient of the first prize for safety essay and also for safety slogan,

Recognised as the best employee for the month of July 2000 and

Received the Electrical Supervisor Licensing from Gujarat government.

Accountabilities

Responsible for the maintenance as the in- charge of substation, plan, schedule and execution the job in SAP Pm module

Well versed with the SAP PM Module as end user an implemented ecc 6.0 version.

Use various condition monitoring techniques such as Thermograph of 220 kV and 33 kV switchyard clamp, connector, la, ct, cvt, transformer and SRI insulator.

Handle numerous tests like the

LA testing using LCM 2 Method and replace accordingly,

Gantry insulator testing using PID method,

Breaker testing for timing and contact resistance,

Cable tan delta, Polarization Index value and IR testing.

33 KV breaker contact resistance, vacuum, timing and functional test

On- line cable termination testing for partial discharge,

Transformer testing ratio test, vector group test and

Winding tan delta, winding resistance, PI value, Magnetic balance test,

220 kv/33 kV current transformer, cvt, pt testing

Harmonic fitter bank capacitance bank testing.

Deftly conduct Ultrasonic scanning with ultra-probe 9000 of 220 kV switchyard, 33 kV switchboard, and cable gallery for partial discharge.

Proficient at Vibration measurement of cooling system motors, flow measurement of cooling system water and thickness measurement of air reservoir

Conduct proactive and prompt maintenance through maintenance planning at the sub-station like over hauling of transformer, Oil and gasket replacement and Transformer oil filtration.

Responsible for the material management at the sub-station as well

Credited for commissioning the fire detector system,

Manage the operation, troubleshooting, execution where required as per sap pm module and maintenance of

33 kV harmonic filter bank

Transformer protection system, high velocity sprinkle system and n2 purging fire fighting system

220 kV isolator arm replacement along with alignment and 220 kV breaker maintenance

As In charge of 220/33/6.6 KV substation coordinate with external service provider for services (scope of work, execution, safety, billing) and with purchase department and vendor for material purchase grid management.

Knowledgeable about relay testing and setting of different Electromagnetic English Electric Relay, ABB and Siemens make static and digital and co-ordination of power system.

Handle power system study in co-ordinator with external agency.

Implement Lock out and tag out with permit system and failure mode analysis of equipment and operate the high velocity sprinkle system of transformer protection, cable tunnel protection, medium velocity sprinkle system, fire door and fire barrier maintenance.

Handle the ION metering system commissioning, 5's implementation of department and is well versed with the ABT system base scheduling of power.

Actively involved in three six sigma green belt and Quality circle projects.

QC project on Handled tripping reduction of SVC in closed loop control under voltage during voltage dip.

Root cause analysis of faults and tripping of equipments.

Exposure in project execution like monitoring & coordination of material, human resources, subcontractors, supervisior, planners, execution of all activities.

Strong problem solving, analytical and organizing skill along with the ability to motivate and lead team.

PREVIOUS WORK ASSIGNMENTS

Essar Steel India Ltd., Hazira, Surat

May’2008 to Jun’2009 Manager

May’2005 to May’2008 Senior Engineer

May’2004 to May’2005 Engineer

Aug’1996 to May’2004 Shift In-Charge

EDUCATION

2013 M.B.A (Finance),

Sikkim Manipal University

2012 Energy Manager Certification

BEE, Government of India

2006 B.E (Electrical)

Institute of Engineers (India)

1996 Diploma in Power and Electronics,

Technical Education Board, Gujarat

1993 HSCE, Adarsh Vidaylay, Patan

Gujarat Higher Secondary Education Board,

1991 SSCE, Shri B.D.HighSchool, Patan

Gujarat Secondary Education Board,

PROFESSIONAL ENHANCEMENT TRAININGS

Trainings through Essar Steel India Ltd

Lt Switchgear, Nov’1999

LT and HT Cable Jointing Feb’2000

Basic Managerial Skills, Oct’2000

Design Aspect of Switchboard, Dec’2000

Transformer and its Protection, Jul’2001

Communication Skills, Sept’2001

Condition Monitoring of Transformer Oil, Electrical research and development association, Nov’2001

Grid Paralleling and Islanding, Nov’2001

Executive Leadership Camp, Nov’2003

Condition Monitoring, Oct’2004

Safety Training for Safety Champion, Jul’2005

Basic Yoga Course, Oct’2005

Heat Exchanger, Mar’2006

Operation and Programming of ABB AC 800PEC Controller for SVC Training,

Total Productive Maintenance, Mar’2006

Industrial Electronics, Jun’2006

ABB-Turgi, Switzerland, June 2006

OTHER PROFESSIONAL TRAININGS

PLC Training on Somatic S5, Cotmac electronics Jul’1998

Scada and its Application in Power Utilizes, Hyderabad, India, and Engineer staff college of India, Hyderabad, Mar’ 2000

HT and LT Motor and it Protection System, Power Linker training centre, Oct’2004

Fault Current Calculation, Relay Setting and Relay Co-Ordination, Power Linker training centre, Oct’2004

Project Work Full Wave Firing Circuit of THYRISTOR power Controller under /Over Voltage Relay with Timer in Dr. S. & S. S. Ghandhy College of Engineering and Technology

220 KV line & Transformer bay erection testing, commissioning.

33 KV & 6.6 KV switchboard erection, testing and commissioning

160/135 MVA transformer erection, testing and commissioning.

33 KV Static var compensator erection,testing Commissionin.g

IT SKILLS

Application: Windows xp, Internet Applications, Microsoft office 2003

LANGUAGES

English

Hindi

Gujarati



Contact this candidate