JENERIO B. FERNANDEZ JR.

Saudi Oger LTD.,Thuwal,Jeddah,Saudi Arabia

Mobile No: +966-***-***-***/+63-919-***-****

Email Add: acplrj@r.postjobfree.com/acplrj@r.postjobfree.com

Skype Account: fernandez6467

Seeking a challenging opportunity that can share my ability and skills to

promote company goals and

objectives

EMPLOYMENT DETAILS

Saudi Oger Limited [KAUST Project]

Jeddah,Kingdom of Saudi Arabia

Fire Alarm System Maintenance Technician

September 07,2012-Present

Duties and Responsibilities

. Conducting daily Preventive Maintenance (PPM) for fire alarm system in

Residential and Facilities

The testing was applicable in accordance with NFPA 72 National Fire

Alarm Code

Coordinate from security and fire department prior to start the task to

prevent miscommunication

. Handling Fire Alarm brand:Edward System Technology products-Quick Start

Panel,and EST3 Panel

conventional and analog addressable system combination of FM200 fire

suppression system

. Responsibilities for installation,troubleshooting,programing and

testing of fire alarm system

. Performed semi and annual inspections and preventive maintenance

service of fire alarm system

. Installed,modefies,maintained program and repair fire alarm panels such

as QS1,QS4 and EST3

. Installed pullstations,smoke,heat,duct detectors and relay modules siga

CR,CT1,CT2,CC1,etc

. Connected fire alarm open-close relay modules (siga CR) to 24v supply

from contactors of three

phase motors of AC/HVAC and elevators,purpose of automaticaly CUTOFF

during alarm activited

. Examine system to locate problems such as loose connections or broken

insulations

. Adjusts sensitivity of units (smoke devices) based on room structures

and recommendations

. Test device detectors and checked dirty percentage (80% dirty need to

be replaced)

. Checked backup batteries (not lower than 24v DC,replace if needed)

. Test and checked load voltage and discharge voltage (ON alarm

status,not lower than 24V DC)

. Test charging voltage (OFF alarm status,not lower than 26 volts DC)

. Replaced PS6 Card,SLIC Card, changing device detectors and add

detectors,modules,SLIC Card

. Resolved communication fault trouble,unconfigure device,loop wiring,map

fault,internal trouble,etc.

. Resolved hornstrobe and siga CR (Control Relay) not function (response

program)

. Checked panel program ensuring device massages are correct in its

location

. Configuration,Disable and Enable loop maping for changing device or

module if needed

. Maintain records,files and preparing reports and orders of materials to

use

. Complies with all applicable health and safety procedures policies and

stablished work practices

Citi Hardware Incorporated

Dumaguete City,Negros Or.,Philippines

Electrical Maintenance and Services

May 2005-May 2012

Duties and Responsibilities

. Read and interpret blue prints for the purpose of determining efficient

installation

. Maintained,repaired,installed troubleshooting lectrical wiring

connections

. Spliced,joined,insulated wire,pull wires,put into tubing and fixed to

wall and other concealed areas

. Performed building wiring and house wiring connections

. Connected 3way and 4way switch,connected wires,cables to circuit

breakers,socket outlets and

other components using electrical tools and power tools

. Performed wiring for upgrade and expansions

ACADEMIC BACKGROUND

4yr. College Degree Negros Oriental State University

Year completed 2004

Electricity Major

High School San Miguel Prv'l.Com.High School

Year completed 2000

CERTIFICATE

WORK PERMIT RECEIVER Saudi Oger Ltd. ( KAUST Project )

Exp.June 2015

for Cold work,Hot work and Confined Space Entry

Cert.no. 180713130

SKILLS

. Computer literate MS word,Office tools,Internet surfing

. Fluent in Oral and Written English Communication Skills

. Teamwork,Coordination,Time management,Reporting Skills,Dependability

REFERENCES

Mr. Danilo G. Due Engr. Glend P.

Sedentario

Asst. Manager Bldg. Control and System Duty Manager

EMCOR company (ARAMCO Project) EMCOR Facilities

Services

054******* 054*******

Email: acplrj@r.postjobfree.com

acplrj@r.postjobfree.com