MOHAMMED YOUSUF
Mobile # +** (0-740*******
acgs7u@r.postjobfree.com
Career Pr?cis
Dynamic, result-oriented and action-focused professional, offering an
experience of over 2 years in HVAC Industry. Possessing personnel
management skills with an ability to manage high-profile projects,
workers and sub-contractors. Excellent communication skills summed up
with splendid knowledge of HVAC. Hands-on experience of working with
tools like Auto-CAD, MS-Office, CATIA V5 R16, R17 and R18, IDEAS 10-11-
12, ANSYS.
Innovative and exceptionally creative to foster ideas that impels the
organization towards a result-oriented direction. Adroit at analyzing the
organization's requirements and identify non-compliant areas in social
compliance. Impeccable client management and leadership skills with
impressive professional speaking abilities. Driven by new challenges and
adept at adapting to any cultural and business environments.
Highly motivated with a strong urge to learn new technologies with hard
work and will to accomplish difficult tasks. With a brilliant
professional record I aspire to join as HVAC Engineer where in my
diligence and exceptional technical expertise contribute to the growth of
the organization.
Related Strengths
. Proficient in concepts of HVAC
. Practical exposure of working on Chillers, Ductable systems, VRF and
Room A.C, Auto-CAD and MS-Office
. Well versed with Duct designing.
. Personnel Management.
. Managing labors and sub-contractors.
. Project Planning/Coordination
. Analytical and Problem solving abilities
Achievements
. Received applause from one of the esteemed client for shifting two
AHU's and one FCU in strict deadlines and reducing piping cost by
giving single drain pipe for two adjacent AHU's.
. Won First Prize in the Mechanical equipments Quiz held at PLES Road
Show held at Infosys Technologies Ltd.
. Received Second Prize in the Environment Quiz organized in the
college.
Professional Experience
HVAC Engineer
may 15-2012
NETBOOM TECHNOLOGIES HYDERABAD.
. Determine tonnage, machine, etc., based on the site and client's
requirement
. Design Duct layout drawing and assist in purchase of machines.
. Responsible for the installation and erection of the machines as per
the site requirements.
. Maintaining the reports on the project progress like AMC, invoice,
follow-up reports.
. Act as a mentor for the new team members enabling them to perform
better.
Key Projects Handled
Client Kishore
Project More
Duration 8 Months
Role Installation Engineer
Capacity 340 Tonnes
Description
The site was a commercial building needing total air CFM of 160,000
that was achieved by installing 4 Blue Star's water cooled scroll
chiller of 85 Tonnes and 1 stand by of 85 Tonnes. The project was
completed in a period of about 8 months which includes time taken for
client meetings, co-ordination meetings, duct fabrication and
installation & erection of ducting, AHU's & FCU's.
Client Maphar constructions
Project Aliens Towers
Duration 7 months
Role Installation Engineer
Capacity 155 Tonnes
Description
The site was a residential cum commercial building with a requirement
of total air CFM of 64,000 which was achieved by installing 4 water
cooled scroll chiller of 39 Tonnes and 1 stand by of 39 Tonnes. The
project was completed in a period of about 6 months which includes
time taken for client meetings, co-ordination meetings, duct
fabrication and installation & erection of ducting, AHU's & FCU's.
Client ITC
Project ITC Paper Ltd.
Duration 3 Months
Role HVAC Engineer
Capacity 115 Tonnes
Description
The site was a paper factory needing total air CFM of 70,000 which was
achieved by installing 5 Blue Star's Precision A.C. (PCPA) of 23
Tonnes each. The project was completed in a period of 3 months which
includes time taken for client meetings, co-ordination meetings, duct
designing, duct fabrication, ordering of machines and it's
installation and erection.
Client S.Kumar
Project SKS Towers
Duration 4 Months
Role HVAC Engineer
Capacity 185 Tonnes
Description
The site was a commercial building needing total air CFM of 65,000
which was achieved by installing 11 Blue Star's ductable split A.C. of
17 Tonnes each. The project was completed in a period of 3 months
which includes time taken for client meetings, co-ordination meetings,
duct designing, duct fabrication, ordering of machines and it's
installation and erection.
Client Nilgiris Super Market
Project Dhriti Super Market
Duration 3 Days
Role HVAC Engineer
Capacity 22 Tonnes
Description
The site was a super market employing ductable split A.C. The total
air CFM needed was 8,000; which was achieved by employing 2 Blue
Star's ductable split A.C. machines. The project was completed in a
time period of 3 days.
Education
Bachelor of Engineering - Mechanical - 67%
2007
Sri Sai jyothi college of Engineering, Hyderabad
Technical Skills
Skills Building Survey, Heat load
calculation, Duct design, Selection of chillers, AHU,
FCU, Exhaust fan, Blowers and Pumps.
Languages C and C++.
Operating Systems MS DOS and Windows
Packages MS-Office App Suite
Trainings Attended
HVAC Training
2010
NETBOOM TECHNOLOGIES of HVAC, Hyderabad
Personal Detail
Date Of Birth 17 SEP, 1992
Marital Status Unmarried
Languages Known English, Hindi, marathi, Telugu and Urdu
Nationality Indian
Passport Details L2211190 Valid till 2023