Resume:

RESUME

SHARATH SHRIKARA SHETTY

GARDEN VIEW, **6, 5TH FLOOR OPP

GERIMERI GARDEN DAHISER (EAST)

MUMBAI PIN - 400068

acggak@r.postjobfree.com

PERSONAL INFORMATION

Birth Date : 3/12/1985

Marital Status : UN married

Contact Number : +918*********,

Nationality : Indian

Languages Known : English, Hindi, Kannada Tamil, Telugu &

Tulu.

QUALIFICATION & ACADEMICS:

Educational:

Secured 2nd Class in S.S.C. Exam (Mangalore University)

Secured 2nd Class H.S.C (Arts) Exam (Mangalore University)

Industrial Training Institute (ITI) 2 Years Course In Manipal. Perdoor

P.W.D. License No: - 237094

Additional Qualification:

Certificate of Syndicate Institute of Rural Entrepreneurship Development

(SIRD) (Domestic Electrical Appliances Repair (Manipal)

WORK EXPERIENCE:

1) Presently working with HILTON SHILLIM ESTATE RETREAT & SPA,

Lonavala as Engineering Supervisor.

This is a 320 acre, 100 villa property with 70 acre of Spa which

is one of the largest area for Spa Treatments in India.

Responsible for complete shift operations and smooth running of

the retreat during the shift. Activities involve electrical,

plumbing, fire fighting, carpentry, painting, polishing, civil, swimming pool, horticulture and pest control activities.

2) Worked with Shetty Infra Services Pvt. Ltd, Mumbai for a period

of 6 months as Operation Executive handling site operation in

Mumbai region.

3) Worked with Shetty Infra Services Pvt. Ltd., Bangalore for J.P.

Morgan Chase site as Shift Engineer in charge of HT / LT

maintenance.

Worked with Shetty Infra Services Pvt Ltd., Bangalore for a

period of 1 year as Operation Executive looking after Bangalore

and Chennai operation.

4) Worked with TURNKEY Electrical Engineers Pvt. Ltd, Mumbai for

a period of 2 years - Site : LVSB (Tata communication) as a

Shift Engineer responsible for HT & LT line & IDC (internet data

center) Maintenance

4) Worked with Property Solution (I) Pvt. Ltd. Mumbai for a

period of 1 year - Site : Tata Communication, BKC as Multi

skill Supervisor

5) Worked with 3 Global Services, Mumbai for a period of 1 year as

a Electrical Supervisor - Site : Prism Tower Malad.

6) Worked with Shetty Associates, Mumbai for a period of 1 year as

electrician - Site : TCS, SEEPZ Andheri & as a Senior

Electrician at Site : Tata Communication, Andheri.

7) Worked with Praveen Electrical, Mumbai for a period of 6 Months

Involved with Projects for Building Wiring & Cinema Theatre

Wiring at FAME, Dahisar Mumbai.

8) Worked with Maria Electrical Mangalore for a period of 6 months

as an Electrician. Involved with Domestic Electrical Appliances

Repair & House Wiring / Building Wiring Projects.

Job Profile:

a) Worked on HT Substation with Incomers 33KV, 22KV and 11 KV

lines.

b Operation and Maintenance of H.T. Panel & L.T. Panel

complete with all Switchgears.

c) Maintenance of 2500 KVA - 4 Nos Transformer & 1600

KVA- 3 No. Transformer

d) Operation and Maintenance of 2500 KVA - 4 nos & 1500

KVA 3 no & 800 KVA 2 No DG set (Water Cooled ) and

maintenance of 5 Nos. Cooling Towers connected to D G Set.

e) Operation and maintenance of DG sets working in

synchronization.

f) Operation and Maintenance of 800 TR 2 Nos. Chiller

Plant

g) Maintenance of 200 KVA 2 Nos, 400 KVA - 4 Nos. & 800

KVA - 19 Nos. UPS was EMERSON & MGE makes

h) Maintenance of SMPS,3600 Amps - 2 Nos.

i) Maintenance of EMERSON PAC unit in 150 No (30TR) & 3 Nos.

(20TR)

j) Maintenance of the BMS System in FM 200, FE 227 &VESDA,

WLD & FAS system & CCTV. Make : Honeywell system

k) Maintenance and Operation of R.T.C.C. Panel- 5 Nos.

l) Maintenance of Three / Single phase motor.

PLACE : Mumbai