Post Job Free

Resume

Sign in

Manager Engineer

Location:
Seattle, WA
Posted:
October 10, 2014

Contact this candidate

Resume:

PAT MATHEWS, CPE RESUME OF QUALIFICATIONS

**** ** ***** ****** *****: acgbzg@r.postjobfree.com

Federal Way, Washington 98023 Telephone: 253-***-****

OBJECTIVE

A challenging position in facilities operations, management, or systems engineering within a

proactive team environment.

SUMMARY OF QUALIFICATIONS

Experience:

Over thirty years of facilities operations, management, engineering, and maintenance experience:

Designing installing repairing servicing troubleshooting machinery of all kinds including

refrigeration H.V.A.C. systems diesel/gasoline/turbine engines high/low voltage electrical

systems hydraulic/hydronic/ pneumatic systems life safety/fire alarm/sprinkler systems

computerized energy management and building automation control systems

video/audio/surveillance systems emergency/disaster recovery systems critical data centers

Technical skill sets: Computer systems networking/programming/repair security systems

DDC & CMMS systems design/programming/integration – Siemens / Steafa / Distech / Reliable /

Johnson Controls mechanical/electrical/electronics systems design/engineering/installation

AutoCAD and all Microsoft Office applications.

Trade skills: Welding machining precision milling plumbing sheet metal general

construction carpentry electrical refrigeration.

Administrative skills: Managing facilities and shops with crews of up to 25 technicians

budgeting inventory purchasing warehousing contract administration bid estimating and

preparations plan review and specification management code compliance project

management.

Special Expertise:

Troubleshooting and repair of any type of mechanical system. Refrigeration and controls

specialist. Project management from concept through closeout and warranty.

Accomplishments:

Building automation controls business development from the ground up. Becoming a factory

trained authorized dealer for Distech (LONworks), Reliable (BACnet), and Johnson Controls.

Commission, operation, and facilities management of the Russell Building, a 12 story 225,000

square foot state of the art office complex. Designed, installed, and programmed a 6000+ point

Distributed Digital Control system controlling 4 facilities totaling nearly 500,000 square feet.

Strengths:

Detail and results oriented self starter self motivated work well with individuals from all

backgrounds function well and effectively under pressure adapt well to adverse work

conditions and circumstances good oral/written communication skills proven leadership

abilities strong sense of professionalism and company loyalty I pride myself on the quality of

my work.

Page 1 of 4

PAT MATHEWS, CPE RESUME OF QUALIFICATIONS

EMPLOYMENT HISTORY

2/08 to present

Senior Programs Manager / Controls Group Operations Manager

HDR, INC.

Facilities Services Group

Fife, WA 98424 - 253-***-****

Building automation systems; business development, R & D, sales engineering, project estimation and

proposal, design, programming, installation, and service. FM/CMMS software development. Project

management and commissioning MEP design review. Commissioning, Test & Balance, Facility

Management, and Controls business management.

8/11 to 8/14

Operations Manager / Maintenance Manager

Tyee Marina

Tacoma, WA - 253-***-****

Marina operations and maintenance crew management. Capital and maintenance budgeting and project

management. Code compliance and marina representative with DNR and other regulatory agencies. Part-

time on weekends.

11/05 to 2/08

Controls Group Operations Manager / Senior Project Manager

HEERY INTERNATIONAL, INC.

Facilities Services Group

Tacoma, WA 98406 - 253-***-****

Same duties as HDR, Inc.; essentially relocated the business to another corporation.

4/04 to 11/05

Project Engineer / Service Manager

T. I. NORTHWEST CORPORATION

Puyallup, WA 98372 - 253-***-****

HVAC Service and IAQ manager, safety and operations manager, project engineer, major projects manager,

sales estimator.

1988-2004

Chief Engineer

FRANK RUSSELL COMPANY

Tacoma, Washington 98401 - 253-***-****

Facilities management, mechanical/electrical/plant engineering, repair, maintenance, operations, and capital

projects management for the Frank Russell Company world headquarters campus.

1982-1988

Chief Facilities and Plant Engineer / Millwright

NORTHWEST DOOR OF TACOMA

Tacoma, Washington 98444 - 253-***-****

Plant, fleet, and facilities management. Engineering, repair, and maintenance for the Northwest’s largest

overhead door manufacturing plant. Including the installation and delivery fleet.

1977-1982

H.V.A.C. Service and Operations Manager

WESTERN FURNACES, INC.

1973-1977

Machinery Technician Second Class (MK2/E5)

U.S. COAST GUARD

Various Duty Stations / Vietnam Era Veteran

Page 2 of 4

PAT MATHEWS, CPE RESUME OF QUALIFICATIONS

EDUCATION

Formal education programs:

GREEN RIVER COMMUNITY COLLEGE

Auburn, Washington 1982-83 (66 credits)

Courses in business, mechanical engineering, machining.

HIGHLINE COMMUNITY COLLEGE

Midway, Washington 1979-80 (32 credits)

Real Estate Certificate, business, contract law, and engineering courses.

L.H. BATES VOCATIONAL - TECHNICAL INSTITUTE

Tacoma, Washington 1977-79

Apprenticeship program in sheetmetal and refrigeration service for S.M.A.C.N.A. local #150.

U.S. COAST GUARD - MACHINERY TECHNOLOGY SCHOOL

Yorktown, Virginia 1973

A two-year program combining machinist mate/engineman/boilerman rates; completed in six

months. Note: returned to teach refrigeration.

Some certifications, seminars, and continuing education programs I have attended:

RELIABLE CONTROLS

Victoria, BC 2007

Factory training for Reliable controls and BACnet protocol certification.

JOHNSON CONTROLS

Seattle, WA 2006

DISTECH CONTROLS

Montreal, Canada 2006

Factory training for Distech Control and LONworks protocol certification.

FRANK RUSSELL COMPANY – Management Series

Port Ludlow, WA 2002

A CEU certified / 120 hour / 3-part management and leadership skills development seminar series.

AFE

Worcester, Maine 2000

Certified Plant Engineer

An extensive multi-discipline certification program covering mechanical engineering, electrical

engineering, civil engineering, structural engineering, and environmental engineering.

PACIFIC LUTHERAN UNIVERSITY

Tacoma, Washington 1998

Supervisory Survival Skills

AEE

Los Angeles, California 1998

Facilities Management / Energy Deregulation

ASHRAE

Dallas, Texas 1996 Seattle, WA 1997

HVAC Design for Noise and Vibration / Indoor Air Quality /

Water System Design / Air System Design and Retrofit

Page 3 of 4

PAT MATHEWS, CPE RESUME OF QUALIFICATIONS

EDUCATION (continued)

NORTHWEST POWER QUALITY SERVICE CENTER

Tigard, Oregon 1993

Motor and VFD user workshops

RSES

Vancouver, Washington 1993

Distributed Digital Control systems

EPA proper refrigerant usage certification

CHEM-AQUA

Tacoma, Washington 1990

Principles of cooling tower water treatment

GENERAL ELECTRIC

Tyler, Texas 1977 - 1981

Six programs on H.V.A.C. engineering, sales, service, installation, design, and layout.

Licenses:

Certified Plant Engineer State of Washington 01 Journeyman Electrical Administrators License State of

Washington 07 Non-residential Maintenance Electrician License City of Tacoma Class III (high-pressure)

Boilerman's License EPA Refrigerant Certification U.S. Merchant Mariners Document WA Drivers

License.

Affiliations:

ASHRAE (American Society of Heating Refrigeration and Air conditioning Engineers)

AFE (Association of Facilities Engineers)

NFPA (National Fire Protection Association)

RSES (Refrigeration Service Engineers Society)

AEE (Association of Energy Engineers)

WSSHE (Washington State Society for Healthcare Engineering)

Business Ventures:

FRIDAYS CONSULTING 1996 to present

Owner (side business)

A consulting firm providing mechanical and HVAC system design, facilities management analysis, building

commissioning, control systems design, and other engineering services.

Page 4 of 4



Contact this candidate