Post Job Free

Resume

Sign in

Industrial Maintenance Technician.

Location:
Memphis, TN
Salary:
36,500
Posted:
March 23, 2015

Contact this candidate

Resume:

Gerald M. Smith **** Graceland Cove, Memphis, TN

38116

Pri. 901-***-****

acg5gs@r.postjobfree.com

[pic]

Summary of Qualifications

Multi - tasked professional with over 23 years of experience in Electronics

eager to contribute technical expertise and troubleshooting background, as

well as strong project management and customer service skills, in a

challenging Electronics Engineer Technology role actively supporting an

organization in maximizing performance.

[pic]

Career Profile

Many years of experience in electronics equipment maintenance and repair.

Skilled consultant and advisor to clients and management.

Proven systems testing and upgrading capacity.

Record of progression to positions of increasing authority and

responsibility.

Proficient in servicing motherboards, PLC, plotter, printers and digital

cameras, HVAC, Level Detectors

Toxic Monitor, PH Meters, CCTV Flowchart Recorder, Panel Alarm Temperature

Module, ATM,IRD Vibration

Demonstrated understanding of MCC's, PLC's, HMI's, VFD's, Servos,

Instrumentation, Industrial networking, Motor controls, I/O Systems, AC/DC

Electrical

Adept in installation/set-up and managing hardware upgrades.

Strength in troubleshooting and maintaining computer hardware.

Effectively interact with diverse groups and professionals at all levels.

Well organized multi-tasked with strong detail orientation.

Adept in aligning engineering contributions with organizational objectives.

Enthusiastic team player.

[pic]

Technology Skills

Microsoft Office Suite, IBM/Apple/Compaq/Dell/HP hard drives, laptop

motherboards & all other electronic devices

[pic]

PROFESSIONAL EXPERIENCE & ACCOMPLISHMENTS

Gerald Smith Associates Recruitment

January 2011 - present

President / Office Manager (48WK)

Well organized multi-tasked with strong detail orientation.

Adept in aligning engineering contributions with organizational objectives.

Enthusiastic team player.

In this position I search for professional candidates for jobs.

I post current and update jobs on the social websites search.

I speak with candidates and Hiring Managers to setup interviews.

I recruit Technical in the areas of Information Technology, Engineers and

Technicians.

This is a work from home investment position.

Flextronics October 2000 - January 2010

Test Technician 1 (40/WK)

This position is responsible for testing, and repairing electrical,

mechanical, electromechanical and electronic, recording, and indicating

instruments and equipment for conformance to established standards, and

assists in formulating repair standards by performing the duties listed

below. Repairs made to board level.

KEY RESPONSIBILITIES:

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

? Tasked with bench repair responsibilities on laptops to board

level.

Troubleshoot and repaired hard drives on Apple, IBM,Compaq, Dell and HP

equipment.

Final tested HP plotters and bench repaired Kodak cameras/printers entering

results into Flex-Flo network system. Ran TeraSci power station to test

Hard Drives and Optical Drives.

Work in Dell Inbound Dept. to asset laptop condition for damages, test

power functions.

Work in the Recovery Dept. to capture good products for laptop buildup.

Due to exemplary troubleshooting capabilities, reduced costs and labor

while increasing productivity and efficiency in performing repairs.

Talent Force Staffing Agy.

August 1999 -

October 2000

Electronic Technician (40/WK)

This position is responsible for testing, and repairing electrical,

mechanical, electromechanical and electronic, recording, and indicating

instruments and equipment for conformance to established standards, and

assists in formulating repair standards by performing the duties listed

below. Repairs made to board level.

KEY RESPONSIBILITIES:

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

Work in the Recovery Dept. to capture good products for laptop buildup.

Work as bench technician on IBM and Apple Computers in the Recovery Dept

using test beds or markups

to test the sub-assemblies.

All data record enter Oracle Application network for job performance.

Due to exemplary troubleshooting capabilities, reduced costs and labor

while increasing productivity and efficiency in performing repairs.

Work as bench technician on IBM and Apple Computers in the Recovery Dept

using test beds or markups

to test the sub-assemblies.

All data record enter Oracle Application network for job performance.

Affiliated Computer Service

April 1998 - January 1999

Field Service Technician (40/WK)

This position is responsible for testing, calibrating, and repairing

electrical, mechanical, electromechanical and electronic measuring,

recording, and indicating instruments and equipment for conformance to

established standards, and assists in formulating calibration standards by

performing the duties listed below.

KEY RESPONSIBILITIES:

. Sets up standard and special-purpose measurement equipment in customers'

facilities.

. Disassembles instruments and equipment, and inspects components for

defects.

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

. Installs new equipment in customers' facilities.

Work on ATM equipment in Memphis and rural areas. Troubleshooting was

perform to sub-assemblies

level POS card readers, monitors, mainframe computers, keyboards and pads.

Adjust voltages on older units in the field. ATM models that was service

were Fujitsu, NCR, Diebold and others located in convenient stores :

Krogers, Police Precinct, Healthcare, NBC and Regions Banks

Responsible for assisting customers in repairs.

Responsible for inventory control on equipment mention above.

On call 24/7 driven company's van.

Circuit Test Inc.

March

1995 - February 1998

Electronic Technician (40/WK)

This position is responsible for testing, and repairing electrical,

mechanical, electromechanical and electronic, recording, and indicating

instruments and equipment for conformance to established standards, and

assists in formulating repair standards by performing the duties listed

below. Repairs made to component level.

KEY RESPONSIBILITIES:

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

Repair Apple monitors to component level using DVM, Oscilloscope, Signal

Generator, High Voltage Probe, blue prints and schematic

drawings.

Labor Ready Staffing Agency.

September 1993 - February

1995

Construction Aide

Buildup and tear down of landscape using hand tools.

MC N. Stiles Treatment Plant

March 1983 -

June 1991

Control Technician (40/WK)

This position is responsible for testing, calibrating, and repairing

electrical, mechanical, electromechanical and electronic measuring,

recording, and indicating instruments and equipment for conformance to

established standards, and assists in formulating calibration standards by

performing the duties listed below. Repairs made to component level.

KEY RESPONSIBILITIES:

. Disassembles instruments and equipment, and inspects components for

defects.

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

Maintenance and service Virian & Cromemco Computers, all troubleshooting

performing to board level.

Used IRD vibration equipment in servicing the calibration on rpm and

amperes on 220v-480v large centrifugal KSB pumps and blowers.

Calibrated Toxic Monitor that monitor 4 gases : oxygen deficiency,

methylene, chloride, methane, and

hydrogen sulfide.

Calibrated Panel Alarm Temperature Monitor for the centrifugal pumps and

blowers.

Responsible for Endress Housing Level sensor calibration.

Used Honeywell analog calibrator to qualify, calibrate all electro-

mechanical limitorque butterfly valves and

flow meters operation and DVM, Oscilloscope, Signal

Generator, Clamp Amp probe, blue prints and

schematics used on other equipment at plant. Program Onron

and Allen Bradley PLC's

Help engineer and install RTD's for each blower at plant and maintenance

VFD.

Perform work on MCC's, PLC's, HMI's, VFD's, Servos, Instrumentation,

Industrial networking, Motor controls, I/O Systems, AC/DC Electrical at a

Dewatering Facilities with pneumatic presses.

All troubleshooting on these equipment and devices mention above was

perform to component level.

WREC/WZXR Inc.

October 1982 -

March 1983

Broadcast Engineer (40/WK)

This position is responsible for testing, calibrating, and repairing

electrical, mechanical, electromechanical and electronic measuring,

recording, and indicating instruments and equipment for conformance to

established FCC standards, and assists in formulating calibration standards

by performing the duties listed below. Repairs made to component level.

KEY RESPONSIBILITIES:

. Disassembles instruments and equipment, and inspects components for

defects.

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

Troubleshoot and repair logic circuitry on power supplies and other

devices.

Help setup promotions of live broadcast on the street/job site.

Help with the installation on RCA BC7 console for the AM newsroom and

Auditronic 218 console for the

FM newsroom.

On a weekly basis calibrated remote control for AM and STL for FM to ensure

system was within FCC

guidelines.

Test Power Diesel Generator for backup operations. On call for emergency

service.

Communication Professional Inc.

March 1980 -

April 1982

Quality Control Technician (40/WK)

This position is responsible for testing, calibrating, and repairing

electrical, mechanical, electromechanical and electronic measuring,

recording, and indicating instruments and equipment for conformance to

established standards, and assists in formulating calibration standards by

performing the duties listed below. Repairs made to component level.

KEY RESPONSIBILITIES:

. Disassembles instruments and equipment, and inspects components for

defects.

. Aligns, repairs, replaces, and balances component parts and circuitry.

. Reassembles and calibrates instruments and equipment.

. Complies with ISO calibration standards when required by the customer.

Work in the Test Dept on telephone equipment, Selectors, Connectors, Line

finders, ITT crossbar circuitry.

Responsible for timing switches and adjusted mechanically to specification

sheet for accuracy with all

troubleshooting performing to component level using DVM and

special tools.

ACCOMPLISHMENTS

Train others in the area of troubleshooting and repair that improve

productivity.

Recognized by foreman for engineering a gpm reading on polymer press in

conjunction with Allen Bradley PLC Controller for quality control.

Installation of Burglar Alarm System at New De-Watering Facilities.

Received 2 certificate 1) IRD VIBRATION ANALYST 2) Cromix Software

Development.

Assist with implementing computer program changes that greatly improved

plant energy usage that resulted in substantial cost reduction and

accuracy.

Assisted in implementing a preventative and predictive maintenance program.

Performed maintenance duties following strict work instructions set forth

through ISO 9002 plant Certification.

My attendant record in the field of technology is above 98%.

As a repair tech repaired scrap flow meters saving money on the purchase of

new products.

Good customer relations skills.

[pic]

Education

East High School, Memphis TN. 1974

State Technical Institute at Memphis 1976

Associate of Applied Science, Electronic Technology

ADDITIONAL TRAINNING: Introduction to DOS, Advanced DOS

Certificate Cromix Operating System

Certificate IRD Qualified Vibration Analyst

ISO 9002 ? Chemical Handing ? Electrical Safety ? Lockout/Tagout

Emergency response ? HAZWRAP ? HAZMAT? E-Squad ? 5's



Contact this candidate