Post Job Free

Resume

Sign in

Sr. Instrumentation/Operator

Location:
United States
Posted:
April 26, 2014

Contact this candidate

Original resume on Jobvertise

Resume:

Ramon S. Pendon

# *** *. ****** **. ******, Pililla, Rizal

+63-928******* / 943-***-****

acdvc6@r.postjobfree.com

Position Desired: Sr. Instrumentation / Operator

OBJECTIVE

To attain a challenging and responsible career position in the established Organization where I can contribute the best of my knowledge and effort for my career advancement and for the organization and be a part of the team that excels in works towards the growth and success of the organization in the company.

SUMMARY OF EXPERIENCE

Having 5 years in work in Philippines, 9 years experience in Oil and Gas companies in their Field and DCS-Panel/Field Operation with plant Start-up, Shutdown, Pre-commissioning, Commissioning and HSE activities.

EDUCATION

MERALCO FOUNDATION INSTITUTE (Nov. 1-18, 2010)

Trainning Course: Instrument Calibration

Chino Roses Avenue, Ortigas City

DON BOSCO TECHNICAL INSTITUTE (1998 ? 2000)

Course: Instrumentation & Control

Chino Roses Avenue, Makati City

MALAYA NATIONAL HIGH SCHOOL (1994 ? 1998)

Malaya, Pililla, Rizal

NIOGAN ELEMENTARY SCHOOL (1989 ? 1994)

Niogan, Pililla, Rizal

WORK EXPERIENCE / RESPONSIBILITIES

HYUNDAI HEAVY INDUSTRIES

Dec 3, 2012 ? Dec. 4, 2013

DAS ISLAND, Abudhabi, UAE, OFFSHORE

Company Industry: Oil / Gas / Petroleum

Plant Operator

? Ensure and must be check all the safety standard procedures and guidelines as per Commissioning Safety manual, ( PTW, PPE, HAZOP, SAFETY BARIERS, SAFETY EQUIPENT, ACCESS,) ETC.., to assure a safe start-up for us, equipment and environment.

? As Field Operator - Monitoring on shift in the assigned operating area, the operation of processing plant and all equipment and ongoing maintenance work. It includes regular inspection of operations (field tours), adjustment of a variety of valves and switches, maintaining all equipment in synchronization and taking and analysing log readings from a variety of gauges and indicators. Reports any anomalies noted to his Supervisor and/or to the Operator in control room duty.

? Responsible in implementing Commissioning and Startup of all process instruments and system line-up within Dehydration is a process of water removal from the drying by substances which is called glycol solution also the system of Fuel Gas Treating, H2s removal by MDEA solution.

? Operates and maintains various equipment associated with used oil refining, including pumps, heaters, burners, vacuum system, centrifuge, automation equipment/instruments, control valves, Steam Boilers, Process heaters, etc.

? Perform troubleshooting and repairs on mechanical equipment, pipe fittings, minor line leaks, pumps, valves as Necessary.

? Operates Human-Machine Interface (HMI) at Control Room

? Monitors the operation of plant equipment and systems constantly, to minimize unplanned downtime, solve problems in a timely manner, and to identify opportunities for improvement

? Gathers and reports refinery process parameters through regular checking of process instruments/gauges and visual checking/gauging of process tanks

? Evaluates daily production estimates to identify production shortfalls that may be related to equipment problems, leaks or spills, or changing of process parameters

? Involvement in planning and executing various plant maintenance shutdown activities if required.

? Adhere to and enforce all applicable company safety, health, and environmental policies and procedures

? Implements programs and procedures required to ensure plant cleanliness.

? Implement and Maintain spare parts and preventative maintenance programs and associated Maintenance software.

? Participates in HAZOP analysis.

? Start-up/ Shutdown Operation and Commissioning for Fuel Gas Treating Package

? Start-up/ Shutdown Operation and Commissioning for Gas Dehydration Unit

? Start-up/ Shutdown Operation and Commissioning for Gas Compression System

? Start-up/ Shutdown Operation and Commissioning for Separation System

Pig Receiver, Inlet Filter Separator, Slug Catcher, Gas Scrubber

? Start-up Operation and Commissioning for Flare System

High Pressure and Low Pressure Flare System

? Start-up Operation and Commissioning for Common Facilities / Utilities

Compressed Air System (instrument and Utility Air)

Nitrogen

Utility and Portable Water

Low/High Pressure Steam

Drain and Sewers system

Fire And Gas system

Emergency Diesel Generator

Deluge System

Inergen System

? Experience in Honeywell Experion System

? Experience in computerized maintenance management system

? Simultaneous Operation coordination to the client (ADGAS).

? Ensure all procedure is follow based on Manual and specification.

? Function Test of ESD, DPS, and HIPPS Valve base on Cause & Effect Chart.

? Verify all lines through UFD, BFD, PFD and P&ID.

DAEWOO E & C

October 15, 2010 ? March 15, 2012

GNL-3Z Project, Arzew Algeria, Africa

Company Industry: Oil / Gas / Petroleum

Field Operator

Responsible for general field operations.

Maintain day to day safe operation and update field operation procedure.

Perform daily / weekly routine activities and handover.

Maintain corrosion inhibitor program.

Manpower arrangements, assure integrity of well sites, (fence, gate, etc.,)

Controlling of sampling system.

Maintaining registration documents for PTW.

Responsible for design isolation and LOTO procedures.

Support for plant operation and other teams coordinate with operators to have better control for well shut-in.

Assure correct valves line-up and assist operations on plant troubleshooting.

Function Test of ESD, DPS, and HIPPS Valve base on Cause & Effect Chart.

Verify all lines through PFD, BFD, UFD and P&ID.

Maintains records and communication as required by district manager.

CEGELEC

Seconded to Single Buoy Mouring Inc. (SBM)

MOPUSTOR- YME FIELD REDEVELOPMENT

September 5, 2009 ? September 28, 2010

ADYARD, LIWA 1, Mussaffah, Abu Dhabi, UAE

Company Industry: Oil / Gas / Petroleum

Commissioning Field Operator

Ensure that before proceed to our work must be check all the safety standard procedures and guidelines as per Commissioning Safety manual, ( PTW, PPE, SAFETY BARIERS, SAFETY EQUIPENT, ACCESS,) ETC.., to assure a safe start-up for us,equipment and environment.

Check and Verify the system which is priority in Commissioning / Start up step by step procedure.

Carry out Isolations/De-isolations both Instrument and Mechanical work.

Provide a Technical assistance and support during start-up, steady operation and process shutdown.

Functional testing of instrument and pre-commissioning and commissioning works.

Inspection and confirmation of instrument loop line as per loop diagram and inspection of instrument location as per the latest revision drawing

DAESUN ELECTRIC AND COMMUNICATION CO.,LTD

August 02, 2008 ? August 30, 2009

Sohar, Port OMAN

Company Industry: Oil / Gas / Petroleum

Instrument Commissioning

Simulation, calibration, cause & effect and checking up configuration of all different types of instruments link in the control room console with the SIEMENS Distribution Control system (DCS) Plant emergency shutdown (PESD) Machine Monitoring System (MMS) by Bentley Nevada.

Maintain the operation of the instrument of its optimum performance participate in planning & implementation of all system modification maintaining the life of instrument device by instrument maintaining such as a predictive, preventive and corrective maintenance.

Responsible in Calibration of Field Instruments Trouble-shooting and Repair of all Instruments in the Plant.

Inspection and confirmation of instrument loop line as per loop diagram and inspection of instrument location as per the latest revision drawing

Assign in Calibration and troubleshooting of all motor and instrument in heating medium area and diesel engine area.

We verify that the instrument meets the required specification as per data sheet, instrument loop diagram and P&ID we also checking the 5 points reading alarm set point signal fail and server mismatch of transmitter,Control valve, On-off valve, Blow down Valve and emergency shutdown valve and set up, air requirement as per name plate and data sheet simulation troubleshooting.

ISAM KABBANI AND PARTNERS CO., LTD (SAUDI ARAMCO)

April 23, 2005 ? June 7, 2008

P.O.box 6897 dammam, 31452, K.S.A

Company Industry: Maintenance / Oil & Gas Company

Maintenance Instrument Technician

Direct the work of electricians and instrument technician and other personnel in his area of responsibility.

Performs and/ or directs maintenance on electric, pneumatic and electronic instrument and Control system.

Diagnoses problems or potential problems in control system pneumatic, and electrical and DCS related.

Performs preventive maintenance on electrical and instrument control system and protective switches.

Requisition instrument and electrical maintenance supplies tools and test equipment.

Coordinates instrument repair and test work.

Compiles daily activity reports and inputs to instrument planning function.

Reports the event and the activities to the concerned supervisor in terms of manpower / spares utilized.

Attend to call outs after normal working hours.

Plans and supervises daily Workload in his area. Inspect repairs, test the electrical equipment and protection system and makes final running adjustment.

Have skills to disassemble and reassemble machinery in accordance with specification (such as, but not limited to panels, pumps, level gauges,flow indicators,pressure and temperature indicators and fire alarms equipment.)

Comply safety measures / precautions at all times.

Pre-commissioning for both Electrical and Instrument.

Loop-checking & Simulation testing.

Insulation testing of supply cables, resistively testing.

TOKYO BOSAI SETSUBI CO.,LTD (PHILS.)

April 2, 2003 ? April 15, 2005

# 6 Rosal St. Saint Dominic III Subdivisions, cor. Mindanao Avenue, Banlat, Q.C.

Assigned at Tarlac and Quezon Power Plant as Operation Staff.(detection and suppression system).

Company Industry: Maintenance & Construction

Instrument Foreman (Power Plant)

As per data sheet, instrument loop diagram and P&ID we also checking the 5 points reading alarm set point signal fail and server mismatch of transmitter,Control valve, On-off valve, Blow down Valve and emergency shutdown valve and set up, air requirement as per name plate and data sheet simulation troubleshooting.

Maintain the operation of the instrument of its optimum performance participate in planning & implementation of all system modification maintaining the life of instrument device by instrument maintaining such as a predictive, preventive and corrective maintenance.

Troubleshooting, repair, Installed and maintenance of fire alarm system in commercial

Building, power plant, particularly in Covanta and Tarlac power plant w/c type is conventional and addressable Fire alarm control panel.

Attend to call outs after normal working hours.

MASIPAG MANPOWER AGENCY INCORPORATED

March 10, 2002 ? March 30, 2003

# 1958 C.M. Recto Avenue, M.M.

Assigned at Metropolitan Hospital, Sta. Cruz, Manila

Company Industry: Maintenance

Maintenance Foreman

Experience in troubleshooting, repair, and maintenance of Circuit Breakers, Generator, motors, like, submersible pump, Booster pump, Etc.

Experience in maintenance of medium/large gensets, switchgears (low and medium voltage) Transformers, cable terminators,(automatic transfer switch).

VOLTAGE ELECTRICAL CONTRACTOR CORPORATION

March 2, 2001 ? March 10, 2002

# 5 Saint Catherine St. Perpetual Village, Taguig, Metro Manila

Instrument Foreman

To handle the manpower Timesheet and work assignment as per area.

Experience in team leadership and supervising.

AUTOVEYOR PHILIPPINES CORPORATION

June 29, 2000 ? July 21, 2001

Brgy. Tunasan, Muntinlupa City,Philippines

Instrument Technician

Experience in troubleshooting, repair, and maintenance of conveyor

Attend to call outs after normal working hours

TEST/REFERENCE INSTRUMENT HANDLED

Emerson Process Management 475/375 HART Field Communicator *Digital Multi-meter, * DC Power Supply, * Current/ millivolt signal generator, *Dead Weight Tester with Precision Weights, * Pressure Calibrator/ Vacuum Generator, * Certified Pressure Gauge or Differential Pressure Indicator, * Loop Calibrator/Simulator * Certified Glass Thermometer, *Temperature Bath or Temperature Calibrator, * Hydraulic or Pneumatic Hand Pump/Pneumatic Calibrator, *Standard Resistance Box, *250 Ohms Loop Resistance, *Safety Valve Calibration Bench, Reference Pressure Gauges, and Soap Leakage Test Spray, * Standard gas test cylinder, * Standard Sample Solution.

FIELD INSTRUMENT HANDLED

Rosemount Vortex Flow meter model 8800 * ENDERS + HAUSER (Promag 50) Magnetic Flow meter * YOKOGAWA EJA-1100A Diff. Pressure type Flow meter * YOKOGAWA EJA-430 Pressure Transmitter *FISHER Field Vie instruments (DVC 600) Digital Valve Controller I/P transmitter Diff. Press, Type * ENDERS + HAUSER (Prosinic M) Doppler Ultrasonic Level Transmitter * ROSEMOUNT 8705Flow Tube magnetic flow meter *Oval flow meter * SAMSON Digital Control Valve type 3277 Actuator * HONEYWELL UDC3300 Universal input / controller * SHIMADEN SR Series Temperature controllers * SHIMADEN SD 16 Indicators * YOKOGAWA Indicators * EE Temperature and humidity Transmitters CARLO GAVASSI Level Relay Switch * OMRON E% Series Controllers * CAL 5500 Temperatures Controllers * HORNEL Speed Indicators * Fuji Temperature Controllers * HONEYWELL True line Thermograph * ABB P/I Converter * ROSEMOUNT I/P Converter * Pressure Gauge * Temperature Gauges

FIELD HANDLING EQUIPMENT

Compressors, Condensers, Coolers, Exchangers, Pumps, Boilers, etc..,

SEMINARS ATTENDED

HOT WORK SAFETY

Sohar Aromatics Project

March 18, 2009

KIDDE WET CHEMICAL TECHNICAL TRAINING

Saudi Aramco, Dhahran, KSA

March 27, 2007

YOUTH ENCOUNTER

St. John Bosco Parish

Fr. Edwin Solvia, SDB (youth in charge)

May 19-21, 2000

AWARDS RECEIVED

PERPECT ATTENDANCE AWARD

Hosted by: Pilipinas Shell Foundation, Inc

And Don Bosco Technical Institute, Makati

November 26, 2000

SPECIAL SKILLS

Electromechanical Technician

Process Technician, OIL & GAS

Knowledgeable of PC Operation ( Windows Microsoft office and various software?s )

Computer Technician (Basic)

DRIVER ( Philippine & Gcc License )

PERSONAL DATA

Place of Birth : Niogan,Pililla,Rizal

Civil Status : Married

Sex : Male

Height : 5?4

Weight : 130 lbs (60 kg)

CHARACTER REFERENCES

Engr. Moises (June) Valiente Project Manager

Isam Kabbani, Abqaiq Project

KSA

Engr. Darwil Tirados Process Engineer

CAMERON

Kingdom of UAE

Ver Vindoy Instrumentation Engr.

ADGAS,Das Island

Kingdom of UAE

REMARKS

I hereby certify that the information aforementioned above are true and correct to the best of my knowledge in actual experiences, and I will give and do the best of my work.

RAMON S. PENDON



Contact this candidate